Loading…

Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves

A debonding location imaging technique (DLIT) utilising mixed-frequency Rayleigh waves is reported in this paper to predict the location of debonding in fibre-reinforced polymer (FRP) composite strengthened concrete structures. In the proposed methodology, a piezoceramic transducer network is employ...

Full description

Saved in:
Bibliographic Details
Published in:Engineering structures 2024-09, Vol.314, p.118377, Article 118377
Main Authors: Cao, Yuqiao, Hu, Xianwen, Ng, Ching Tai, Smith, Scott T.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c240t-de9e4a91c1e6245ddf081b5da70fc5bdebb82ac49bad7b189a9744fa9a10a8363
container_end_page
container_issue
container_start_page 118377
container_title Engineering structures
container_volume 314
creator Cao, Yuqiao
Hu, Xianwen
Ng, Ching Tai
Smith, Scott T.
description A debonding location imaging technique (DLIT) utilising mixed-frequency Rayleigh waves is reported in this paper to predict the location of debonding in fibre-reinforced polymer (FRP) composite strengthened concrete structures. In the proposed methodology, a piezoceramic transducer network is employed to sequentially scan the FRP-concrete interface. One of the transducers serves as an actuator while the remainder serve as sensors. The incident waves which are sent by the actuator consist of two different fundamental frequencies. After the incident waves interact with debonding, additional signals are generated that coincide with the sum of the fundamental frequencies (i.e., sum frequency). The received wave component at the sum frequency is in accordance with theoretical predictions. In order to apply the DLIT, a time-frequency analysis is then applied to process the data collected by each actuator-sensor transducer pair in order to determine the signal energy density amplitudes (i.e., signal envelopes) at the fundamental frequencies and the sum frequency. Based on cross-correlation analysis between the signal envelopes of the fundamental frequencies and the sum frequency, an image can be constructed that reveals the centroid of the debonding region. Following the presentation of the proposed DLIT, numerical and experimental studies are then reported that compare the predicted centroid of debonding with the actual centroid of debonding as incorporated into the numerical model and the experimental specimens, respectively. The results demonstrate that the proposed DLIT based on the Rayleigh wave features at sum frequency can satisfactorily predict the location of debonding. •New damage detection method proposed for FRP-strengthened concrete structures.•Generation of sum harmonic due to debonding.•Location of debonding presented graphically by cross-correlation analysis.•Proposed imaging technique verified numerically and experimentally.•Different sizes and locations of debonding are evaluated by proposed method.
doi_str_mv 10.1016/j.engstruct.2024.118377
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_engstruct_2024_118377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0141029624009398</els_id><sourcerecordid>S0141029624009398</sourcerecordid><originalsourceid>FETCH-LOGICAL-c240t-de9e4a91c1e6245ddf081b5da70fc5bdebb82ac49bad7b189a9744fa9a10a8363</originalsourceid><addsrcrecordid>eNqFkM1OAyEURmehibX6DPICM8KUzs-yqVZNmmgaXZML3JnStGCA1vQdfGiZjHHr6nITvsPHybI7RgtGWXW_K9D2IfqjikVJS14w1szq-iKbUMZZTsu2usquQ9hRSsumoZPs-8FAb12IRhFzgN7YnriOaJTO6mExlqw2b3mCJnTcokVNPBrbOa_SUTmrPEYk46tHj4EcwxBU7iCNhWichT3Zgj84a1QgfUJ4iCkrz2QD5z2afku-4IThJrvsYB_w9ndOs4_V4_vyOV-_Pr0sF-tclZzGXGOLHFqmGFYln2vd0YbJuYaadmouU3fZlKB4K0HXkjUttDXnHbTAKDSzajbN6pGrvAvBYyc-ffq8PwtGxSBS7MSfSDGIFKPIlFyMSUz1Tga9CMqgTSaMx3RXO_Mv4wf8Roii</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves</title><source>ScienceDirect Journals</source><creator>Cao, Yuqiao ; Hu, Xianwen ; Ng, Ching Tai ; Smith, Scott T.</creator><creatorcontrib>Cao, Yuqiao ; Hu, Xianwen ; Ng, Ching Tai ; Smith, Scott T.</creatorcontrib><description>A debonding location imaging technique (DLIT) utilising mixed-frequency Rayleigh waves is reported in this paper to predict the location of debonding in fibre-reinforced polymer (FRP) composite strengthened concrete structures. In the proposed methodology, a piezoceramic transducer network is employed to sequentially scan the FRP-concrete interface. One of the transducers serves as an actuator while the remainder serve as sensors. The incident waves which are sent by the actuator consist of two different fundamental frequencies. After the incident waves interact with debonding, additional signals are generated that coincide with the sum of the fundamental frequencies (i.e., sum frequency). The received wave component at the sum frequency is in accordance with theoretical predictions. In order to apply the DLIT, a time-frequency analysis is then applied to process the data collected by each actuator-sensor transducer pair in order to determine the signal energy density amplitudes (i.e., signal envelopes) at the fundamental frequencies and the sum frequency. Based on cross-correlation analysis between the signal envelopes of the fundamental frequencies and the sum frequency, an image can be constructed that reveals the centroid of the debonding region. Following the presentation of the proposed DLIT, numerical and experimental studies are then reported that compare the predicted centroid of debonding with the actual centroid of debonding as incorporated into the numerical model and the experimental specimens, respectively. The results demonstrate that the proposed DLIT based on the Rayleigh wave features at sum frequency can satisfactorily predict the location of debonding. •New damage detection method proposed for FRP-strengthened concrete structures.•Generation of sum harmonic due to debonding.•Location of debonding presented graphically by cross-correlation analysis.•Proposed imaging technique verified numerically and experimentally.•Different sizes and locations of debonding are evaluated by proposed method.</description><identifier>ISSN: 0141-0296</identifier><identifier>DOI: 10.1016/j.engstruct.2024.118377</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Combinational harmonics generation ; Contact acoustic nonlinearity ; Debonding ; FRP-strengthened reinforced concrete ; Imaging ; Rayleigh wave ; Sum harmonic frequency</subject><ispartof>Engineering structures, 2024-09, Vol.314, p.118377, Article 118377</ispartof><rights>2024 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c240t-de9e4a91c1e6245ddf081b5da70fc5bdebb82ac49bad7b189a9744fa9a10a8363</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Cao, Yuqiao</creatorcontrib><creatorcontrib>Hu, Xianwen</creatorcontrib><creatorcontrib>Ng, Ching Tai</creatorcontrib><creatorcontrib>Smith, Scott T.</creatorcontrib><title>Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves</title><title>Engineering structures</title><description>A debonding location imaging technique (DLIT) utilising mixed-frequency Rayleigh waves is reported in this paper to predict the location of debonding in fibre-reinforced polymer (FRP) composite strengthened concrete structures. In the proposed methodology, a piezoceramic transducer network is employed to sequentially scan the FRP-concrete interface. One of the transducers serves as an actuator while the remainder serve as sensors. The incident waves which are sent by the actuator consist of two different fundamental frequencies. After the incident waves interact with debonding, additional signals are generated that coincide with the sum of the fundamental frequencies (i.e., sum frequency). The received wave component at the sum frequency is in accordance with theoretical predictions. In order to apply the DLIT, a time-frequency analysis is then applied to process the data collected by each actuator-sensor transducer pair in order to determine the signal energy density amplitudes (i.e., signal envelopes) at the fundamental frequencies and the sum frequency. Based on cross-correlation analysis between the signal envelopes of the fundamental frequencies and the sum frequency, an image can be constructed that reveals the centroid of the debonding region. Following the presentation of the proposed DLIT, numerical and experimental studies are then reported that compare the predicted centroid of debonding with the actual centroid of debonding as incorporated into the numerical model and the experimental specimens, respectively. The results demonstrate that the proposed DLIT based on the Rayleigh wave features at sum frequency can satisfactorily predict the location of debonding. •New damage detection method proposed for FRP-strengthened concrete structures.•Generation of sum harmonic due to debonding.•Location of debonding presented graphically by cross-correlation analysis.•Proposed imaging technique verified numerically and experimentally.•Different sizes and locations of debonding are evaluated by proposed method.</description><subject>Combinational harmonics generation</subject><subject>Contact acoustic nonlinearity</subject><subject>Debonding</subject><subject>FRP-strengthened reinforced concrete</subject><subject>Imaging</subject><subject>Rayleigh wave</subject><subject>Sum harmonic frequency</subject><issn>0141-0296</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkM1OAyEURmehibX6DPICM8KUzs-yqVZNmmgaXZML3JnStGCA1vQdfGiZjHHr6nITvsPHybI7RgtGWXW_K9D2IfqjikVJS14w1szq-iKbUMZZTsu2usquQ9hRSsumoZPs-8FAb12IRhFzgN7YnriOaJTO6mExlqw2b3mCJnTcokVNPBrbOa_SUTmrPEYk46tHj4EcwxBU7iCNhWichT3Zgj84a1QgfUJ4iCkrz2QD5z2afku-4IThJrvsYB_w9ndOs4_V4_vyOV-_Pr0sF-tclZzGXGOLHFqmGFYln2vd0YbJuYaadmouU3fZlKB4K0HXkjUttDXnHbTAKDSzajbN6pGrvAvBYyc-ffq8PwtGxSBS7MSfSDGIFKPIlFyMSUz1Tga9CMqgTSaMx3RXO_Mv4wf8Roii</recordid><startdate>20240901</startdate><enddate>20240901</enddate><creator>Cao, Yuqiao</creator><creator>Hu, Xianwen</creator><creator>Ng, Ching Tai</creator><creator>Smith, Scott T.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20240901</creationdate><title>Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves</title><author>Cao, Yuqiao ; Hu, Xianwen ; Ng, Ching Tai ; Smith, Scott T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c240t-de9e4a91c1e6245ddf081b5da70fc5bdebb82ac49bad7b189a9744fa9a10a8363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Combinational harmonics generation</topic><topic>Contact acoustic nonlinearity</topic><topic>Debonding</topic><topic>FRP-strengthened reinforced concrete</topic><topic>Imaging</topic><topic>Rayleigh wave</topic><topic>Sum harmonic frequency</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cao, Yuqiao</creatorcontrib><creatorcontrib>Hu, Xianwen</creatorcontrib><creatorcontrib>Ng, Ching Tai</creatorcontrib><creatorcontrib>Smith, Scott T.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>Engineering structures</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cao, Yuqiao</au><au>Hu, Xianwen</au><au>Ng, Ching Tai</au><au>Smith, Scott T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves</atitle><jtitle>Engineering structures</jtitle><date>2024-09-01</date><risdate>2024</risdate><volume>314</volume><spage>118377</spage><pages>118377-</pages><artnum>118377</artnum><issn>0141-0296</issn><abstract>A debonding location imaging technique (DLIT) utilising mixed-frequency Rayleigh waves is reported in this paper to predict the location of debonding in fibre-reinforced polymer (FRP) composite strengthened concrete structures. In the proposed methodology, a piezoceramic transducer network is employed to sequentially scan the FRP-concrete interface. One of the transducers serves as an actuator while the remainder serve as sensors. The incident waves which are sent by the actuator consist of two different fundamental frequencies. After the incident waves interact with debonding, additional signals are generated that coincide with the sum of the fundamental frequencies (i.e., sum frequency). The received wave component at the sum frequency is in accordance with theoretical predictions. In order to apply the DLIT, a time-frequency analysis is then applied to process the data collected by each actuator-sensor transducer pair in order to determine the signal energy density amplitudes (i.e., signal envelopes) at the fundamental frequencies and the sum frequency. Based on cross-correlation analysis between the signal envelopes of the fundamental frequencies and the sum frequency, an image can be constructed that reveals the centroid of the debonding region. Following the presentation of the proposed DLIT, numerical and experimental studies are then reported that compare the predicted centroid of debonding with the actual centroid of debonding as incorporated into the numerical model and the experimental specimens, respectively. The results demonstrate that the proposed DLIT based on the Rayleigh wave features at sum frequency can satisfactorily predict the location of debonding. •New damage detection method proposed for FRP-strengthened concrete structures.•Generation of sum harmonic due to debonding.•Location of debonding presented graphically by cross-correlation analysis.•Proposed imaging technique verified numerically and experimentally.•Different sizes and locations of debonding are evaluated by proposed method.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.engstruct.2024.118377</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0141-0296
ispartof Engineering structures, 2024-09, Vol.314, p.118377, Article 118377
issn 0141-0296
language eng
recordid cdi_crossref_primary_10_1016_j_engstruct_2024_118377
source ScienceDirect Journals
subjects Combinational harmonics generation
Contact acoustic nonlinearity
Debonding
FRP-strengthened reinforced concrete
Imaging
Rayleigh wave
Sum harmonic frequency
title Diagnostic imaging of debonding in FRP-strengthened reinforced concrete structures using combinational harmonics generated by Rayleigh waves
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T19%3A21%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20imaging%20of%20debonding%20in%20FRP-strengthened%20reinforced%20concrete%20structures%20using%20combinational%20harmonics%20generated%20by%20Rayleigh%20waves&rft.jtitle=Engineering%20structures&rft.au=Cao,%20Yuqiao&rft.date=2024-09-01&rft.volume=314&rft.spage=118377&rft.pages=118377-&rft.artnum=118377&rft.issn=0141-0296&rft_id=info:doi/10.1016/j.engstruct.2024.118377&rft_dat=%3Celsevier_cross%3ES0141029624009398%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c240t-de9e4a91c1e6245ddf081b5da70fc5bdebb82ac49bad7b189a9744fa9a10a8363%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true