Simplified protection algorithm for fault detection and localization in DC microgrid

In a microgrid, conventional overcurrent and current direction based protection techniques have limitations during high resistance faults. Besides, ring configuration microgrids offer bidirectional power flow rather than unidirectional power flow. Moreover, DC microgrids own low line resistance and...

Full description

Saved in:
Bibliographic Details
Published in:Electric power systems research 2022-10, Vol.211, p.108229, Article 108229
Main Authors: Nageswara Reddy, Nareddy, Velpula, Rajesh, Raja, P., Moorthi, S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In a microgrid, conventional overcurrent and current direction based protection techniques have limitations during high resistance faults. Besides, ring configuration microgrids offer bidirectional power flow rather than unidirectional power flow. Moreover, DC microgrids own low line resistance and high DC link capacitance; it results in an immense increase in current. During fault conditions, it may cause an undesirable disconnection of resources and make the system unreliable. An accurate and fast operating protection strategy is needed to explore and achieve the above mentioned challenges. To start, with the difference in consecutive current sample data, the current difference index has been evaluated. The non-zero index is granting the estimation of frequency using natural characteristics of fault current, which correctly discriminates an incipient fault and sudden switching loads. Thereafter, by adopting local voltage and current samples during the fault, estimated inductance has been exploited, which possesses polarity and magnitude to isolate the fault and identify the fault position, respectively. The proposed method genuineness for numerous cases like low and high resistance faults at various locations, including close-in faults, bidirectional power flow, different load conditions, and other configurations is validated in MATLAB/Simulink environment. This method precisely estimates fault location under the aforementioned cases. A comparative study of the proposed scheme with existing protection methods has been carried out, proving that this method is more accurate and enhances the relay dependability. •The non-zero value of current difference index triggers the fault detection algorithm.•The estimation of frequency is adopted to discriminate fault inception, load change.•The estimation of inductance is used to isolate fault line and to find fault location.•The proposed protection algorithm works effectively even during high resistance fault.•Comparative study of proposed method with the methods in literature has been done.
ISSN:0378-7796
DOI:10.1016/j.epsr.2022.108229