Loading…

Evaluation of airflow and thermal comfort in buildings ventilated with wind catchers: Simulation of conditions in Yazd City, Iran

The usage of passive cooling systems such as wind catchers can reduce the energy usage in buildings and provide natural ventilation and comfort to its occupants, particularly in hot and dry regions of Iran and neighboring countries where it was traditionally used. The purpose of this study was to in...

Full description

Saved in:
Bibliographic Details
Published in:Energy for sustainable development 2016-12, Vol.35, p.7-24
Main Authors: Hosseini, S.H., Shokry, E., Ahmadian Hosseini, A.J., Ahmadi, G., Calautit, J.K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The usage of passive cooling systems such as wind catchers can reduce the energy usage in buildings and provide natural ventilation and comfort to its occupants, particularly in hot and dry regions of Iran and neighboring countries where it was traditionally used. The purpose of this study was to investigate the airflow and thermal comfort in six different designs of wind catchers using computational fluid dynamics (CFD) technique. Simulations of airflow in the wind catcher and the building were done under steady state and turbulent flow regime with boundary conditions based on typical conditions found in Yazd city, Iran. Several commonly used turbulence models were evaluated to assess the accuracy of the simulation. First, the proposed CFD model was validated through comparison of wind tunnel data available in the literature, and then the model was used for design purposes. It was found that the k−ω turbulence model can accurately predict the airflow velocity in the range of parameters studied. The design and performance of wind catcher were evaluated based on the thermal comfort levels using the Center for the Built Environment (CBE) thermal comfort tool and numerical data. Width and height of the wind catcher were varied in the simulations and optimal values were determined. It was found that varying the width of the wind catcher had the greatest impact on the airflow speed and distribution inside the room. Reducing the width from 2.5m to 2m showed that airflow velocity in the middle area was increased up to 34%. While reducing the width from 2m to 1.5m showed an entirely different flow pattern inside the building and also increase airflow speed in the middle area up to 50%. The addition of curved wall at the bottom of the inlet channel showed that it could increase the airflow speed of the inflow stream, however, it also caused the airflow to be directed towards the lower levels of the room and very large rotating flows in the upper levels. Finally, the results showed that the wind catcher may be optimized for improving comfort for various climates using the tools presented in this work. •Different turbulence models were evaluated for thermal comfort analysis of wind catchers.•Standard k−ω turbulence model provided most accurate prediction of airflow in wind catcher and building.•Various wind catcher geometries focusing on width and height of tower were studied.•Optimum design of wind catcher for ventilation and thermal comfort were evaluated.
ISSN:0973-0826