An alternative method for rapid quantitative analysis of majority cis–trans fatty acids by CZE

An alternative methodology for simultaneous analysis of majority cis–trans fatty acids such as stearic (C18:0), elaidic (C18:1t), oleic (C18:1c), palmitic (C16:0), linoleic (C18:2cc) and linolenic (C18:3ccc) by capillary zone electrophoresis (CZE) under indirect detection was proposed in this work....

Full description

Saved in:
Bibliographic Details
Published in:Food research international 2013-06, Vol.52 (1), p.33-41
Main Authors: de Castro Barra, Patrícia Mendonça, Castro, Renata de Jesus Coelho, de Oliveira, Patrícia Lopes, Aued-Pimentel, Sabria, da Silva, Simone Alves, de Oliveira, Marcone Augusto Leal
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An alternative methodology for simultaneous analysis of majority cis–trans fatty acids such as stearic (C18:0), elaidic (C18:1t), oleic (C18:1c), palmitic (C16:0), linoleic (C18:2cc) and linolenic (C18:3ccc) by capillary zone electrophoresis (CZE) under indirect detection was proposed in this work. The CZE methodology was optimized through the 23 central composite design (23 CCD) with three replicates in central point, having as factors Brij 35, acetonitrile and 1-octanol. The background electrolyte (BGE) for the optimum separation condition consisted of: 15.0mmolL−1 of NaH2PO4/Na2HPO4 buffer at pH≈6.86, 4.0mmolL−1 of SDBS, 8.3mmolL−1 of Brij 35 and 45% v/v of ACN, and 2.1% of 1-octanol was achieved by analyzing of the 23 CCD together with the principal component analysis (PCA). The FA quantification was performed through response factor (Rf) approach, which provided high analytical throughput for the real samples analysis. The CZE method optimized was successfully applied to the analysis of FA in samples of olive oil, soy oil, hydrogenated vegetable fat, butter, margarine and filled cookie. The results obtained were compared with AOCS GC official method (Ce 1j-07) through paired sample t test and no significant difference was found within 95% confidence interval. •Rapid analysis of cis–trans fatty acids by capillary zone electrophoresis (CZE)•CZE compared to official GC method did not present significant difference.•CZE method presents absence of extraction and derivatization in sample preparation.•Short analysis time; low organic solvent consume and high analytical throughput•Common reagents for electrolyte background preparation; use of non-specific columns