Loading…

Measurement of mixing of two miscible liquids in a stirred vessel with electrical resistance tomography

An electrical resistance tomography (ERT) system is used to measure the mixing of two miscible liquids. A data analysis method to monitor and measure the mixing process is proposed. On the basis of the reconstructed pixel conductivity data obtained from multi-plane ERT sensors, the mixing time can b...

Full description

Saved in:
Bibliographic Details
Published in:International communications in heat and mass transfer 2006-11, Vol.33 (9), p.1088-1095
Main Authors: Kim, Sin, Nkaya, Andre Ngansib, Dyakowski, Tomasz
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An electrical resistance tomography (ERT) system is used to measure the mixing of two miscible liquids. A data analysis method to monitor and measure the mixing process is proposed. On the basis of the reconstructed pixel conductivity data obtained from multi-plane ERT sensors, the mixing time can be measured and the best-correlated pairs of pixels are identified to determine the dispersion velocity of the secondary liquid in the primary liquid as well. Experimental results for the mixing of liquids in a stirred tank are presented.
ISSN:0735-1933
1879-0178
DOI:10.1016/j.icheatmasstransfer.2006.06.010