Loading…

Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction

•High fault protection accuracy.•Low operation time delay and high operation speed.•Strong anti-interference ability.•Low sampling rate requirement. Existing non-unit protection schemes are inevitably influenced by the high fault-resistance in MMC-HVDC grid, which is a serious problem affecting the...

Full description

Saved in:
Bibliographic Details
Published in:International journal of electrical power & energy systems 2023-12, Vol.154, p.109469, Article 109469
Main Authors: Yu, D.C., Zhou, N.C., Liao, J.Q., Wang, Q.G., Wei, N.Q.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273
cites cdi_FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273
container_end_page
container_issue
container_start_page 109469
container_title International journal of electrical power & energy systems
container_volume 154
creator Yu, D.C.
Zhou, N.C.
Liao, J.Q.
Wang, Q.G.
Wei, N.Q.
description •High fault protection accuracy.•Low operation time delay and high operation speed.•Strong anti-interference ability.•Low sampling rate requirement. Existing non-unit protection schemes are inevitably influenced by the high fault-resistance in MMC-HVDC grid, which is a serious problem affecting the rapidity and reliability of fault recognition. This study proposes a dynamic fitting of data reconstruction-based protection method to improve the accuracy and rapidity of HVDC grid protection. Due to the propagation characteristics of the initial voltage traveling wave being unaffected by the transition resistance, the self-adapting exponential fitting algorithm is used to recognize the fault waveform. Then, sliding data window with the voltage traveling wave fit by the optimal basis exponential fitting algorithm could avoid the influence of initial value selection on fitting convergence. Meanwhile, the original fault traveling wave is reconstructed by “Bayesian compressed sensing algorithm (BCSA)” in a low sampling rate. This method could reduce the operation response time of the proposed method to satisfy the ultra-high-speed requirement of MMC-HVDC grid and also adapt the limitation of sampling rate in existing protection devices. Practical case studies in PSCAD/EMTDC and protection prototype testing have demonstrated that the proposed method is effective under different fault locations, fault types, and high fault impedance.
doi_str_mv 10.1016/j.ijepes.2023.109469
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_ijepes_2023_109469</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0142061523005264</els_id><sourcerecordid>S0142061523005264</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273</originalsourceid><addsrcrecordid>eNp9kM9OhDAQxjlo4rr6Bh76AqxtKSAXE7P-WZONXtRrUzoDlAAlbdFsfHlZ8exlJvNNvi8zvyi6YnTDKMuu241pcUS_4ZQns1SIrDiJVpQJHtOMpWfRufctpTQvBF9F3y92iKfBBDJ1wam4MXUT-xERyP2WdGZAMjobUAdjB9JjaCyQyjqy-5j3tTPgyeTNUBM4DKo3mlQmhOOsuto6E5qefM2VgAqKONR28MFNv3EX0WmlOo-Xf30dvT8-vG138f716Xl7t491kvIQl0oJEBwyzLTQCS2hTBQFWiagKxBKZ8AAUs54nqSq4rwo8jzheKMwgXIW15FYcrWz3jus5OhMr9xBMiqP0GQrF2jyCE0u0Gbb7WLD-bZPg056bXDQCGb-I0iw5v-AHzlOfNw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction</title><source>ScienceDirect Freedom Collection</source><creator>Yu, D.C. ; Zhou, N.C. ; Liao, J.Q. ; Wang, Q.G. ; Wei, N.Q.</creator><creatorcontrib>Yu, D.C. ; Zhou, N.C. ; Liao, J.Q. ; Wang, Q.G. ; Wei, N.Q.</creatorcontrib><description>•High fault protection accuracy.•Low operation time delay and high operation speed.•Strong anti-interference ability.•Low sampling rate requirement. Existing non-unit protection schemes are inevitably influenced by the high fault-resistance in MMC-HVDC grid, which is a serious problem affecting the rapidity and reliability of fault recognition. This study proposes a dynamic fitting of data reconstruction-based protection method to improve the accuracy and rapidity of HVDC grid protection. Due to the propagation characteristics of the initial voltage traveling wave being unaffected by the transition resistance, the self-adapting exponential fitting algorithm is used to recognize the fault waveform. Then, sliding data window with the voltage traveling wave fit by the optimal basis exponential fitting algorithm could avoid the influence of initial value selection on fitting convergence. Meanwhile, the original fault traveling wave is reconstructed by “Bayesian compressed sensing algorithm (BCSA)” in a low sampling rate. This method could reduce the operation response time of the proposed method to satisfy the ultra-high-speed requirement of MMC-HVDC grid and also adapt the limitation of sampling rate in existing protection devices. Practical case studies in PSCAD/EMTDC and protection prototype testing have demonstrated that the proposed method is effective under different fault locations, fault types, and high fault impedance.</description><identifier>ISSN: 0142-0615</identifier><identifier>DOI: 10.1016/j.ijepes.2023.109469</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Bayesian compressed sensing algorithm (BSCA) ; DC grid equivalent method ; DC grids ; Fault travelling wave (TW) ; Waveform recognition</subject><ispartof>International journal of electrical power &amp; energy systems, 2023-12, Vol.154, p.109469, Article 109469</ispartof><rights>2023 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273</citedby><cites>FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Yu, D.C.</creatorcontrib><creatorcontrib>Zhou, N.C.</creatorcontrib><creatorcontrib>Liao, J.Q.</creatorcontrib><creatorcontrib>Wang, Q.G.</creatorcontrib><creatorcontrib>Wei, N.Q.</creatorcontrib><title>Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction</title><title>International journal of electrical power &amp; energy systems</title><description>•High fault protection accuracy.•Low operation time delay and high operation speed.•Strong anti-interference ability.•Low sampling rate requirement. Existing non-unit protection schemes are inevitably influenced by the high fault-resistance in MMC-HVDC grid, which is a serious problem affecting the rapidity and reliability of fault recognition. This study proposes a dynamic fitting of data reconstruction-based protection method to improve the accuracy and rapidity of HVDC grid protection. Due to the propagation characteristics of the initial voltage traveling wave being unaffected by the transition resistance, the self-adapting exponential fitting algorithm is used to recognize the fault waveform. Then, sliding data window with the voltage traveling wave fit by the optimal basis exponential fitting algorithm could avoid the influence of initial value selection on fitting convergence. Meanwhile, the original fault traveling wave is reconstructed by “Bayesian compressed sensing algorithm (BCSA)” in a low sampling rate. This method could reduce the operation response time of the proposed method to satisfy the ultra-high-speed requirement of MMC-HVDC grid and also adapt the limitation of sampling rate in existing protection devices. Practical case studies in PSCAD/EMTDC and protection prototype testing have demonstrated that the proposed method is effective under different fault locations, fault types, and high fault impedance.</description><subject>Bayesian compressed sensing algorithm (BSCA)</subject><subject>DC grid equivalent method</subject><subject>DC grids</subject><subject>Fault travelling wave (TW)</subject><subject>Waveform recognition</subject><issn>0142-0615</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kM9OhDAQxjlo4rr6Bh76AqxtKSAXE7P-WZONXtRrUzoDlAAlbdFsfHlZ8exlJvNNvi8zvyi6YnTDKMuu241pcUS_4ZQns1SIrDiJVpQJHtOMpWfRufctpTQvBF9F3y92iKfBBDJ1wam4MXUT-xERyP2WdGZAMjobUAdjB9JjaCyQyjqy-5j3tTPgyeTNUBM4DKo3mlQmhOOsuto6E5qefM2VgAqKONR28MFNv3EX0WmlOo-Xf30dvT8-vG138f716Xl7t491kvIQl0oJEBwyzLTQCS2hTBQFWiagKxBKZ8AAUs54nqSq4rwo8jzheKMwgXIW15FYcrWz3jus5OhMr9xBMiqP0GQrF2jyCE0u0Gbb7WLD-bZPg056bXDQCGb-I0iw5v-AHzlOfNw</recordid><startdate>202312</startdate><enddate>202312</enddate><creator>Yu, D.C.</creator><creator>Zhou, N.C.</creator><creator>Liao, J.Q.</creator><creator>Wang, Q.G.</creator><creator>Wei, N.Q.</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202312</creationdate><title>Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction</title><author>Yu, D.C. ; Zhou, N.C. ; Liao, J.Q. ; Wang, Q.G. ; Wei, N.Q.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bayesian compressed sensing algorithm (BSCA)</topic><topic>DC grid equivalent method</topic><topic>DC grids</topic><topic>Fault travelling wave (TW)</topic><topic>Waveform recognition</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yu, D.C.</creatorcontrib><creatorcontrib>Zhou, N.C.</creatorcontrib><creatorcontrib>Liao, J.Q.</creatorcontrib><creatorcontrib>Wang, Q.G.</creatorcontrib><creatorcontrib>Wei, N.Q.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>International journal of electrical power &amp; energy systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yu, D.C.</au><au>Zhou, N.C.</au><au>Liao, J.Q.</au><au>Wang, Q.G.</au><au>Wei, N.Q.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction</atitle><jtitle>International journal of electrical power &amp; energy systems</jtitle><date>2023-12</date><risdate>2023</risdate><volume>154</volume><spage>109469</spage><pages>109469-</pages><artnum>109469</artnum><issn>0142-0615</issn><abstract>•High fault protection accuracy.•Low operation time delay and high operation speed.•Strong anti-interference ability.•Low sampling rate requirement. Existing non-unit protection schemes are inevitably influenced by the high fault-resistance in MMC-HVDC grid, which is a serious problem affecting the rapidity and reliability of fault recognition. This study proposes a dynamic fitting of data reconstruction-based protection method to improve the accuracy and rapidity of HVDC grid protection. Due to the propagation characteristics of the initial voltage traveling wave being unaffected by the transition resistance, the self-adapting exponential fitting algorithm is used to recognize the fault waveform. Then, sliding data window with the voltage traveling wave fit by the optimal basis exponential fitting algorithm could avoid the influence of initial value selection on fitting convergence. Meanwhile, the original fault traveling wave is reconstructed by “Bayesian compressed sensing algorithm (BCSA)” in a low sampling rate. This method could reduce the operation response time of the proposed method to satisfy the ultra-high-speed requirement of MMC-HVDC grid and also adapt the limitation of sampling rate in existing protection devices. Practical case studies in PSCAD/EMTDC and protection prototype testing have demonstrated that the proposed method is effective under different fault locations, fault types, and high fault impedance.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ijepes.2023.109469</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0142-0615
ispartof International journal of electrical power & energy systems, 2023-12, Vol.154, p.109469, Article 109469
issn 0142-0615
language eng
recordid cdi_crossref_primary_10_1016_j_ijepes_2023_109469
source ScienceDirect Freedom Collection
subjects Bayesian compressed sensing algorithm (BSCA)
DC grid equivalent method
DC grids
Fault travelling wave (TW)
Waveform recognition
title Non-unit ultra-high-speed DC line protection method for HVDC grids using dynamic fitting algorithm with data reconstruction
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T16%3A35%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Non-unit%20ultra-high-speed%20DC%20line%20protection%20method%20for%20HVDC%20grids%20using%20dynamic%20fitting%20algorithm%20with%20data%20reconstruction&rft.jtitle=International%20journal%20of%20electrical%20power%20&%20energy%20systems&rft.au=Yu,%20D.C.&rft.date=2023-12&rft.volume=154&rft.spage=109469&rft.pages=109469-&rft.artnum=109469&rft.issn=0142-0615&rft_id=info:doi/10.1016/j.ijepes.2023.109469&rft_dat=%3Celsevier_cross%3ES0142061523005264%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c352t-baa4d42d6e6c4c30bdb3a0d0b3dcfd4ac6d1dd5212735af22997732e8ae3db273%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true