Loading…

Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid

•Simple method for detecting trace amounts of Cd chelators is presented.•Detection was based on the blue-shift in the UV–Vis spectrum of TPPS.•The method can be used to quantify thiol-free chelators. Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and in...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2020-03, Vol.1141, p.122025, Article 122025
Main Authors: Chen, Chia-Shang, Ogawa, Shinya, Imura, Yuki, Suzuki, Michio, Yoshimura, Etsuro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73
cites cdi_FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73
container_end_page
container_issue
container_start_page 122025
container_title Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
container_volume 1141
creator Chen, Chia-Shang
Ogawa, Shinya
Imura, Yuki
Suzuki, Michio
Yoshimura, Etsuro
description •Simple method for detecting trace amounts of Cd chelators is presented.•Detection was based on the blue-shift in the UV–Vis spectrum of TPPS.•The method can be used to quantify thiol-free chelators. Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and induces cytopathic effects in the liver, kidney, and skeletal tissues in humans. Metallothionein and glutathione (GSH) play a major role in the protection against Cd(II)-induced toxicity in mammalian cells. In this study, a relatively simple method for detecting trace amounts of Cd(II) chelators was developed by using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid (TPPS). The TPPS–Cd(II) complex was added to the elutions of high-performance liquid chromatography. The Cd(II) chelators separated by column chromatography were mixed with Cd(II)-bound TPPS (TPPS-Cd(II)). Cd(II) from TPPS-Cd(II) was chelated by the eluted Cd(II) chelators, resulting in the formation of free TPPS. The absorbance of TPPS shifted from 434 nm (TPPS–Cd(II)) to 414 nm (TPPS), and this characteristic shift was used to estimate the quantity and affinity of the Cd(II) chelators. This new method was compared with the bathocuproine disulfonate (BCS) method developed in our previous study. Instead of BCS-Cu(I), TPPS-Cd(II) was used as the colorimetric reagent. The experimental setup of the TPPS-based method is more general, and the preparation of the colorimetric solution is also much simpler than the BCS method. To verify the efficacy of this new method, we determined the actual Cd(II)-chelating ability of GSH in horse blood; the obtained concentration was in good agreement with the previously reported value.
doi_str_mv 10.1016/j.jchromb.2020.122025
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_jchromb_2020_122025</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1570023219315363</els_id><sourcerecordid>S1570023219315363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73</originalsourceid><addsrcrecordid>eNqFkMFu1DAQhiMEoqXwCCA_wHrx2ImdPSFUAVupEhxA4mY59njjVRIHO0Ha9-CB8XYL155mNP__z4y-qnoLbAsM5Pvj9mj7FMduyxkvM15K86y6hlYJKpT8-bz0jWKUccGvqlc5HxkDxZR4WV0JDmynanVd_fkW80JtHNZxIg4XtEuIE4meWOPGsI7E9jiYJaZMuhPpw6GnMyYf02gmi2QIv9bgyMMrxXVIZu5PZM1hOpBmA2wDzYYzuuByVnA6DZTDfsPFns4xzX2Y8EHL6-DjFCwxNrjX1QtvhoxvHutN9ePzp--3e3r_9cvd7cd7amsBC91JbCWT6Hy9876rG95ZkACN8XXrGmmkktx1BlrsjAElTS1aaFvAuoy8EjdVc9lrU8w5oddzCqNJJw1Mnynro36krM-U9YVyyb275Oa1G9H9T_3DWgwfLgYs3_8OmHS2AQsvF1IhrF0MT5z4C1hOkpg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid</title><source>Elsevier</source><creator>Chen, Chia-Shang ; Ogawa, Shinya ; Imura, Yuki ; Suzuki, Michio ; Yoshimura, Etsuro</creator><creatorcontrib>Chen, Chia-Shang ; Ogawa, Shinya ; Imura, Yuki ; Suzuki, Michio ; Yoshimura, Etsuro</creatorcontrib><description>•Simple method for detecting trace amounts of Cd chelators is presented.•Detection was based on the blue-shift in the UV–Vis spectrum of TPPS.•The method can be used to quantify thiol-free chelators. Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and induces cytopathic effects in the liver, kidney, and skeletal tissues in humans. Metallothionein and glutathione (GSH) play a major role in the protection against Cd(II)-induced toxicity in mammalian cells. In this study, a relatively simple method for detecting trace amounts of Cd(II) chelators was developed by using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid (TPPS). The TPPS–Cd(II) complex was added to the elutions of high-performance liquid chromatography. The Cd(II) chelators separated by column chromatography were mixed with Cd(II)-bound TPPS (TPPS-Cd(II)). Cd(II) from TPPS-Cd(II) was chelated by the eluted Cd(II) chelators, resulting in the formation of free TPPS. The absorbance of TPPS shifted from 434 nm (TPPS–Cd(II)) to 414 nm (TPPS), and this characteristic shift was used to estimate the quantity and affinity of the Cd(II) chelators. This new method was compared with the bathocuproine disulfonate (BCS) method developed in our previous study. Instead of BCS-Cu(I), TPPS-Cd(II) was used as the colorimetric reagent. The experimental setup of the TPPS-based method is more general, and the preparation of the colorimetric solution is also much simpler than the BCS method. To verify the efficacy of this new method, we determined the actual Cd(II)-chelating ability of GSH in horse blood; the obtained concentration was in good agreement with the previously reported value.</description><identifier>ISSN: 1570-0232</identifier><identifier>EISSN: 1873-376X</identifier><identifier>DOI: 10.1016/j.jchromb.2020.122025</identifier><identifier>PMID: 32109747</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Animals ; Aporphines - chemistry ; Cadmium - chemistry ; Cadmium chelator ; Chelating Agents - analysis ; Chelating Agents - chemistry ; Chromatography, High Pressure Liquid - methods ; Glutathione ; High-performance liquid chromatography ; Horses ; Limit of Detection ; Oxidative Stress</subject><ispartof>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2020-03, Vol.1141, p.122025, Article 122025</ispartof><rights>2020 Elsevier B.V.</rights><rights>Copyright © 2020 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73</citedby><cites>FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32109747$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, Chia-Shang</creatorcontrib><creatorcontrib>Ogawa, Shinya</creatorcontrib><creatorcontrib>Imura, Yuki</creatorcontrib><creatorcontrib>Suzuki, Michio</creatorcontrib><creatorcontrib>Yoshimura, Etsuro</creatorcontrib><title>Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid</title><title>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</title><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><description>•Simple method for detecting trace amounts of Cd chelators is presented.•Detection was based on the blue-shift in the UV–Vis spectrum of TPPS.•The method can be used to quantify thiol-free chelators. Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and induces cytopathic effects in the liver, kidney, and skeletal tissues in humans. Metallothionein and glutathione (GSH) play a major role in the protection against Cd(II)-induced toxicity in mammalian cells. In this study, a relatively simple method for detecting trace amounts of Cd(II) chelators was developed by using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid (TPPS). The TPPS–Cd(II) complex was added to the elutions of high-performance liquid chromatography. The Cd(II) chelators separated by column chromatography were mixed with Cd(II)-bound TPPS (TPPS-Cd(II)). Cd(II) from TPPS-Cd(II) was chelated by the eluted Cd(II) chelators, resulting in the formation of free TPPS. The absorbance of TPPS shifted from 434 nm (TPPS–Cd(II)) to 414 nm (TPPS), and this characteristic shift was used to estimate the quantity and affinity of the Cd(II) chelators. This new method was compared with the bathocuproine disulfonate (BCS) method developed in our previous study. Instead of BCS-Cu(I), TPPS-Cd(II) was used as the colorimetric reagent. The experimental setup of the TPPS-based method is more general, and the preparation of the colorimetric solution is also much simpler than the BCS method. To verify the efficacy of this new method, we determined the actual Cd(II)-chelating ability of GSH in horse blood; the obtained concentration was in good agreement with the previously reported value.</description><subject>Animals</subject><subject>Aporphines - chemistry</subject><subject>Cadmium - chemistry</subject><subject>Cadmium chelator</subject><subject>Chelating Agents - analysis</subject><subject>Chelating Agents - chemistry</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Glutathione</subject><subject>High-performance liquid chromatography</subject><subject>Horses</subject><subject>Limit of Detection</subject><subject>Oxidative Stress</subject><issn>1570-0232</issn><issn>1873-376X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkMFu1DAQhiMEoqXwCCA_wHrx2ImdPSFUAVupEhxA4mY59njjVRIHO0Ha9-CB8XYL155mNP__z4y-qnoLbAsM5Pvj9mj7FMduyxkvM15K86y6hlYJKpT8-bz0jWKUccGvqlc5HxkDxZR4WV0JDmynanVd_fkW80JtHNZxIg4XtEuIE4meWOPGsI7E9jiYJaZMuhPpw6GnMyYf02gmi2QIv9bgyMMrxXVIZu5PZM1hOpBmA2wDzYYzuuByVnA6DZTDfsPFns4xzX2Y8EHL6-DjFCwxNrjX1QtvhoxvHutN9ePzp--3e3r_9cvd7cd7amsBC91JbCWT6Hy9876rG95ZkACN8XXrGmmkktx1BlrsjAElTS1aaFvAuoy8EjdVc9lrU8w5oddzCqNJJw1Mnynro36krM-U9YVyyb275Oa1G9H9T_3DWgwfLgYs3_8OmHS2AQsvF1IhrF0MT5z4C1hOkpg</recordid><startdate>20200315</startdate><enddate>20200315</enddate><creator>Chen, Chia-Shang</creator><creator>Ogawa, Shinya</creator><creator>Imura, Yuki</creator><creator>Suzuki, Michio</creator><creator>Yoshimura, Etsuro</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20200315</creationdate><title>Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid</title><author>Chen, Chia-Shang ; Ogawa, Shinya ; Imura, Yuki ; Suzuki, Michio ; Yoshimura, Etsuro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Animals</topic><topic>Aporphines - chemistry</topic><topic>Cadmium - chemistry</topic><topic>Cadmium chelator</topic><topic>Chelating Agents - analysis</topic><topic>Chelating Agents - chemistry</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Glutathione</topic><topic>High-performance liquid chromatography</topic><topic>Horses</topic><topic>Limit of Detection</topic><topic>Oxidative Stress</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Chia-Shang</creatorcontrib><creatorcontrib>Ogawa, Shinya</creatorcontrib><creatorcontrib>Imura, Yuki</creatorcontrib><creatorcontrib>Suzuki, Michio</creatorcontrib><creatorcontrib>Yoshimura, Etsuro</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Chia-Shang</au><au>Ogawa, Shinya</au><au>Imura, Yuki</au><au>Suzuki, Michio</au><au>Yoshimura, Etsuro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid</atitle><jtitle>Journal of chromatography. B, Analytical technologies in the biomedical and life sciences</jtitle><addtitle>J Chromatogr B Analyt Technol Biomed Life Sci</addtitle><date>2020-03-15</date><risdate>2020</risdate><volume>1141</volume><spage>122025</spage><pages>122025-</pages><artnum>122025</artnum><issn>1570-0232</issn><eissn>1873-376X</eissn><abstract>•Simple method for detecting trace amounts of Cd chelators is presented.•Detection was based on the blue-shift in the UV–Vis spectrum of TPPS.•The method can be used to quantify thiol-free chelators. Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and induces cytopathic effects in the liver, kidney, and skeletal tissues in humans. Metallothionein and glutathione (GSH) play a major role in the protection against Cd(II)-induced toxicity in mammalian cells. In this study, a relatively simple method for detecting trace amounts of Cd(II) chelators was developed by using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid (TPPS). The TPPS–Cd(II) complex was added to the elutions of high-performance liquid chromatography. The Cd(II) chelators separated by column chromatography were mixed with Cd(II)-bound TPPS (TPPS-Cd(II)). Cd(II) from TPPS-Cd(II) was chelated by the eluted Cd(II) chelators, resulting in the formation of free TPPS. The absorbance of TPPS shifted from 434 nm (TPPS–Cd(II)) to 414 nm (TPPS), and this characteristic shift was used to estimate the quantity and affinity of the Cd(II) chelators. This new method was compared with the bathocuproine disulfonate (BCS) method developed in our previous study. Instead of BCS-Cu(I), TPPS-Cd(II) was used as the colorimetric reagent. The experimental setup of the TPPS-based method is more general, and the preparation of the colorimetric solution is also much simpler than the BCS method. To verify the efficacy of this new method, we determined the actual Cd(II)-chelating ability of GSH in horse blood; the obtained concentration was in good agreement with the previously reported value.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>32109747</pmid><doi>10.1016/j.jchromb.2020.122025</doi></addata></record>
fulltext fulltext
identifier ISSN: 1570-0232
ispartof Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 2020-03, Vol.1141, p.122025, Article 122025
issn 1570-0232
1873-376X
language eng
recordid cdi_crossref_primary_10_1016_j_jchromb_2020_122025
source Elsevier
subjects Animals
Aporphines - chemistry
Cadmium - chemistry
Cadmium chelator
Chelating Agents - analysis
Chelating Agents - chemistry
Chromatography, High Pressure Liquid - methods
Glutathione
High-performance liquid chromatography
Horses
Limit of Detection
Oxidative Stress
title Post-column detection of cadmium chelators by high-performance liquid chromatography using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T05%3A18%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Post-column%20detection%20of%20cadmium%20chelators%20by%20high-performance%20liquid%20chromatography%20using%205,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic%20acid&rft.jtitle=Journal%20of%20chromatography.%20B,%20Analytical%20technologies%20in%20the%20biomedical%20and%20life%20sciences&rft.au=Chen,%20Chia-Shang&rft.date=2020-03-15&rft.volume=1141&rft.spage=122025&rft.pages=122025-&rft.artnum=122025&rft.issn=1570-0232&rft.eissn=1873-376X&rft_id=info:doi/10.1016/j.jchromb.2020.122025&rft_dat=%3Celsevier_cross%3ES1570023219315363%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c431t-96e8606edf49ffb452bc16115af48d56a6762dba18ebaa176a4381881e418ef73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/32109747&rfr_iscdi=true