Loading…

Intervendor Differences in the Accuracy of Detecting Regional Functional Abnormalities

Abstract Objectives The purpose of this study was to compare the accuracy of vendor-specific and independent strain analysis tools to detect regional myocardial function abnormality in a clinical setting. Background Speckle tracking echocardiography has been considered a promising tool for the quant...

Full description

Saved in:
Bibliographic Details
Published in:JACC. Cardiovascular imaging 2018-01, Vol.11 (1), p.25-34
Main Authors: Mirea, Oana, MD, PhD, Pagourelias, Efstathios D., MD, PhD, Duchenne, Jurgen, MSc, Bogaert, Jan, MD, PhD, Thomas, James D., MD, Badano, Luigi P., MD, PhD, Voigt, Jens-Uwe, MD, PhD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Objectives The purpose of this study was to compare the accuracy of vendor-specific and independent strain analysis tools to detect regional myocardial function abnormality in a clinical setting. Background Speckle tracking echocardiography has been considered a promising tool for the quantitative assessment of regional myocardial function. However, the potential differences among speckle tracking software with regard to their accuracy in identifying regional abnormality has not been studied extensively. Methods Sixty-three subjects (5 healthy volunteers and 58 patients) were examined with 7 different ultrasound machines during 5 days. All patients had experienced a previous myocardial infarction, which was characterized by cardiac magnetic resonance with late gadolinium enhancement. Segmental peak systolic (PS), end-systolic (ES) and post-systolic strain (PSS) measurements were obtained with 6 vendor-specific software tools and 2 independent strain analysis tools. Strain parameters were compared between fully scarred and scar-free segments. Receiver operating characteristic curves testing the ability of strain parameters and derived indexes to discriminate between these segments were compared among vendors. Results The average strain values calculated for normal segments ranged from −15.1% to −20.7% for PS, −14.9% to −20.6% for ES, and −16.1% to −21.4% for PSS. Significantly lower values of strain (p < 0.05) were found in segments with transmural scar by all vendors, with values ranging from −7.4% to −11.1% for PS, −7.7% to −10.8% for ES, and −10.5% to −14.3% for PSS. Accuracy in identifying transmural scar ranged from acceptable to excellent (area under the curve 0.74 to 0.83 for PS and ES and 0.70 to 0.78 for PSS). Significant differences were found among vendors (p 
ISSN:1936-878X
1876-7591
DOI:10.1016/j.jcmg.2017.02.014