Loading…

Accuracy of the analytical demagnetization tensor for various geometries

We investigate the accuracy of the analytical expressions for the magnetostatic demagnetization tensor for three different geometries by comparing these to the dipole field at far-away distances. We consider a prism, tetrahedron and cylindrical tile geometry. We show that for the prism and tetrahedr...

Full description

Saved in:
Bibliographic Details
Published in:Journal of magnetism and magnetic materials 2023-12, Vol.587, p.171245, Article 171245
Main Authors: Bjørk, R., d’Aquino, M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c295t-1f54c1b569927945edd793d2dfdfdea5111cc9e90bbd225223aa0c53d48791c83
container_end_page
container_issue
container_start_page 171245
container_title Journal of magnetism and magnetic materials
container_volume 587
creator Bjørk, R.
d’Aquino, M.
description We investigate the accuracy of the analytical expressions for the magnetostatic demagnetization tensor for three different geometries by comparing these to the dipole field at far-away distances. We consider a prism, tetrahedron and cylindrical tile geometry. We show that for the prism and tetrahedron tiles the median relative error compared to the dipole field reaches below 10−7 at 200 tile radii away from the generating tile, while the cylindrical tile has a median relative error of about 10−5 at this distance. Even at a distance of 104 tile radii the relative error is below 10−2 for all tiles, also when single precision is used to calculate the magnetic field. This shows that the demagnetization tensor is an accurate way of calculating the stray magnetic field also for far-away distances. •We systematically investigate the accuracy of the analytical demagnetization tensor.•We consider three tile geometries, the prism, tetrahedron and cylinder.•We compare the demagnetization field to the dipole field far away from the tile.•The median relative error compared to the dipolar field is below 10−5 at 200 tile radii for all tiles.•Even at 104 tile radii the median relative error is below 10−2 for all tiles.
doi_str_mv 10.1016/j.jmmm.2023.171245
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_jmmm_2023_171245</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0304885323008958</els_id><sourcerecordid>S0304885323008958</sourcerecordid><originalsourceid>FETCH-LOGICAL-c295t-1f54c1b569927945edd793d2dfdfdea5111cc9e90bbd225223aa0c53d48791c83</originalsourceid><addsrcrecordid>eNp9j81KAzEUhbNQsFZfwFVeYMb8TGYm4KYUtULBja5DenOnZpiZSJIW6tM7pa7lcrir73A-Qh44Kznj9WNf9uM4loIJWfKGi0pdkQWTrCraVskbcptSzxjjVVsvyGYFcIgWTjR0NH8htZMdTtmDHajD0e4nzP7HZh8mmnFKIdJuztFGHw6J7jGMmKPHdEeuOzskvP_7S_L58vyx3hTb99e39WpbgNAqF7xTFfCdqrUWja4UOtdo6YTr5kOrOOcAGjXb7ZwQSghpLQMlXdU2mkMrl0RceiGGlCJ25jv60caT4cyc_U1vzv7m7G8u_jP0dIFwXnb0GE0CjxOg8xEhGxf8f_gvdkBnXg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Accuracy of the analytical demagnetization tensor for various geometries</title><source>ScienceDirect Journals</source><creator>Bjørk, R. ; d’Aquino, M.</creator><creatorcontrib>Bjørk, R. ; d’Aquino, M.</creatorcontrib><description>We investigate the accuracy of the analytical expressions for the magnetostatic demagnetization tensor for three different geometries by comparing these to the dipole field at far-away distances. We consider a prism, tetrahedron and cylindrical tile geometry. We show that for the prism and tetrahedron tiles the median relative error compared to the dipole field reaches below 10−7 at 200 tile radii away from the generating tile, while the cylindrical tile has a median relative error of about 10−5 at this distance. Even at a distance of 104 tile radii the relative error is below 10−2 for all tiles, also when single precision is used to calculate the magnetic field. This shows that the demagnetization tensor is an accurate way of calculating the stray magnetic field also for far-away distances. •We systematically investigate the accuracy of the analytical demagnetization tensor.•We consider three tile geometries, the prism, tetrahedron and cylinder.•We compare the demagnetization field to the dipole field far away from the tile.•The median relative error compared to the dipolar field is below 10−5 at 200 tile radii for all tiles.•Even at 104 tile radii the median relative error is below 10−2 for all tiles.</description><identifier>ISSN: 0304-8853</identifier><identifier>DOI: 10.1016/j.jmmm.2023.171245</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Accuracy ; Demagnetization tensor ; Magpylib ; MagTense ; Numerical</subject><ispartof>Journal of magnetism and magnetic materials, 2023-12, Vol.587, p.171245, Article 171245</ispartof><rights>2023 The Author(s)</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c295t-1f54c1b569927945edd793d2dfdfdea5111cc9e90bbd225223aa0c53d48791c83</cites><orcidid>0000-0002-3728-2326 ; 0000-0002-5321-5772</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Bjørk, R.</creatorcontrib><creatorcontrib>d’Aquino, M.</creatorcontrib><title>Accuracy of the analytical demagnetization tensor for various geometries</title><title>Journal of magnetism and magnetic materials</title><description>We investigate the accuracy of the analytical expressions for the magnetostatic demagnetization tensor for three different geometries by comparing these to the dipole field at far-away distances. We consider a prism, tetrahedron and cylindrical tile geometry. We show that for the prism and tetrahedron tiles the median relative error compared to the dipole field reaches below 10−7 at 200 tile radii away from the generating tile, while the cylindrical tile has a median relative error of about 10−5 at this distance. Even at a distance of 104 tile radii the relative error is below 10−2 for all tiles, also when single precision is used to calculate the magnetic field. This shows that the demagnetization tensor is an accurate way of calculating the stray magnetic field also for far-away distances. •We systematically investigate the accuracy of the analytical demagnetization tensor.•We consider three tile geometries, the prism, tetrahedron and cylinder.•We compare the demagnetization field to the dipole field far away from the tile.•The median relative error compared to the dipolar field is below 10−5 at 200 tile radii for all tiles.•Even at 104 tile radii the median relative error is below 10−2 for all tiles.</description><subject>Accuracy</subject><subject>Demagnetization tensor</subject><subject>Magpylib</subject><subject>MagTense</subject><subject>Numerical</subject><issn>0304-8853</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9j81KAzEUhbNQsFZfwFVeYMb8TGYm4KYUtULBja5DenOnZpiZSJIW6tM7pa7lcrir73A-Qh44Kznj9WNf9uM4loIJWfKGi0pdkQWTrCraVskbcptSzxjjVVsvyGYFcIgWTjR0NH8htZMdTtmDHajD0e4nzP7HZh8mmnFKIdJuztFGHw6J7jGMmKPHdEeuOzskvP_7S_L58vyx3hTb99e39WpbgNAqF7xTFfCdqrUWja4UOtdo6YTr5kOrOOcAGjXb7ZwQSghpLQMlXdU2mkMrl0RceiGGlCJ25jv60caT4cyc_U1vzv7m7G8u_jP0dIFwXnb0GE0CjxOg8xEhGxf8f_gvdkBnXg</recordid><startdate>20231201</startdate><enddate>20231201</enddate><creator>Bjørk, R.</creator><creator>d’Aquino, M.</creator><general>Elsevier B.V</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-3728-2326</orcidid><orcidid>https://orcid.org/0000-0002-5321-5772</orcidid></search><sort><creationdate>20231201</creationdate><title>Accuracy of the analytical demagnetization tensor for various geometries</title><author>Bjørk, R. ; d’Aquino, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c295t-1f54c1b569927945edd793d2dfdfdea5111cc9e90bbd225223aa0c53d48791c83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Accuracy</topic><topic>Demagnetization tensor</topic><topic>Magpylib</topic><topic>MagTense</topic><topic>Numerical</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bjørk, R.</creatorcontrib><creatorcontrib>d’Aquino, M.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><jtitle>Journal of magnetism and magnetic materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bjørk, R.</au><au>d’Aquino, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy of the analytical demagnetization tensor for various geometries</atitle><jtitle>Journal of magnetism and magnetic materials</jtitle><date>2023-12-01</date><risdate>2023</risdate><volume>587</volume><spage>171245</spage><pages>171245-</pages><artnum>171245</artnum><issn>0304-8853</issn><abstract>We investigate the accuracy of the analytical expressions for the magnetostatic demagnetization tensor for three different geometries by comparing these to the dipole field at far-away distances. We consider a prism, tetrahedron and cylindrical tile geometry. We show that for the prism and tetrahedron tiles the median relative error compared to the dipole field reaches below 10−7 at 200 tile radii away from the generating tile, while the cylindrical tile has a median relative error of about 10−5 at this distance. Even at a distance of 104 tile radii the relative error is below 10−2 for all tiles, also when single precision is used to calculate the magnetic field. This shows that the demagnetization tensor is an accurate way of calculating the stray magnetic field also for far-away distances. •We systematically investigate the accuracy of the analytical demagnetization tensor.•We consider three tile geometries, the prism, tetrahedron and cylinder.•We compare the demagnetization field to the dipole field far away from the tile.•The median relative error compared to the dipolar field is below 10−5 at 200 tile radii for all tiles.•Even at 104 tile radii the median relative error is below 10−2 for all tiles.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.jmmm.2023.171245</doi><orcidid>https://orcid.org/0000-0002-3728-2326</orcidid><orcidid>https://orcid.org/0000-0002-5321-5772</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0304-8853
ispartof Journal of magnetism and magnetic materials, 2023-12, Vol.587, p.171245, Article 171245
issn 0304-8853
language eng
recordid cdi_crossref_primary_10_1016_j_jmmm_2023_171245
source ScienceDirect Journals
subjects Accuracy
Demagnetization tensor
Magpylib
MagTense
Numerical
title Accuracy of the analytical demagnetization tensor for various geometries
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T07%3A51%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20of%20the%20analytical%20demagnetization%20tensor%20for%20various%20geometries&rft.jtitle=Journal%20of%20magnetism%20and%20magnetic%20materials&rft.au=Bj%C3%B8rk,%20R.&rft.date=2023-12-01&rft.volume=587&rft.spage=171245&rft.pages=171245-&rft.artnum=171245&rft.issn=0304-8853&rft_id=info:doi/10.1016/j.jmmm.2023.171245&rft_dat=%3Celsevier_cross%3ES0304885323008958%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c295t-1f54c1b569927945edd793d2dfdfdea5111cc9e90bbd225223aa0c53d48791c83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true