Experimental assessment of the effects of a porous double skin façade system on cladding loads

The high-efficiency façades, such as porous double skins, have become increasingly popular due to the recent technological progress in architecture. The so-called porous double skin façade (DSF) systems, which are constituted by a permeable layer over a closed inner façade, are often adopted to redu...

Full description

Saved in:
Bibliographic Details
Published in:Journal of wind engineering and industrial aerodynamics 2020-01, Vol.196, p.104019, Article 104019
Main Authors: Pomaranzi, G., Daniotti, N., Schito, P., Rosa, L., Zasso, A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The high-efficiency façades, such as porous double skins, have become increasingly popular due to the recent technological progress in architecture. The so-called porous double skin façade (DSF) systems, which are constituted by a permeable layer over a closed inner façade, are often adopted to reduce the system energy demand. However, as expected, the porous skin alters the wind-induced pressures acting on the inner façade. Therefore, the cladding loads for such a façade system has to be accurately estimated performing wind tunnel tests. Using the low-rise buildings of the New Bocconi Campus as a case study, we present the experimental wind tunnel methodologies utilized to assess the wind-induced peak pressures acting on the inner glazed skin of the porous double skin façade system designed for the case at hands. In particular, the reduction of both the positive and negative peak pressures estimated for the inner façade is addressed when comparing the standard façade to the porous DSF case. In addition, the valuable data set of the pressure signals acquired for the porous DSF system studied, allows one to investigate the dependence of the computed peak pressures on the averaging time utilized for the extreme value estimates. •Wind tunnel test has been performed on a rigid scaled model of a building with a permeable double skin façade•Positive and negative peak pressures on the inner skin are up to 40% lower than the corresponding ones for a standard façade•Pressure signals in the inner skin show lower mean values/std deviation than the corresponding ones for a standard façade•Dependency of the peak pressures on the averaging time is more evident for the single façade case than for the permeable one
ISSN:0167-6105
1872-8197
DOI:10.1016/j.jweia.2019.104019