Loading…

Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography

•Proposed a new two-coil magnetic core inductor for ECPT.•Two-coil magnetic core inductor increases the detectable area and visual quality for ECPT.•The uniformity of the temperature distribution on the detection object is improved.•Geometric parameters and the working parameters of the two-coil mag...

Full description

Saved in:
Bibliographic Details
Published in:Measurement : journal of the International Measurement Confederation 2021-04, Vol.174, p.109063, Article 109063
Main Authors: Xiao, Xiang-Tao, Liang, Zheng, Zhang, Liang, Tang, Song
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3
cites cdi_FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3
container_end_page
container_issue
container_start_page 109063
container_title Measurement : journal of the International Measurement Confederation
container_volume 174
creator Xiao, Xiang-Tao
Liang, Zheng
Zhang, Liang
Tang, Song
description •Proposed a new two-coil magnetic core inductor for ECPT.•Two-coil magnetic core inductor increases the detectable area and visual quality for ECPT.•The uniformity of the temperature distribution on the detection object is improved.•Geometric parameters and the working parameters of the two-coil magnetic core inductor are studied. Eddy current pulse thermography (ECPT) is an active thermography technology in the nondestructive testing field. The inductor of ECPT is an important component that influences detection quality and efficiency. In this paper, a two-coil magnetic core inductor is proposed for ECPT, which characteristics are investigated by numerical simulation methods. This new structure enlarges the detectable area for ECPT and increases the view field for infrared cameras. Research results show that the uniformity of temperature distribution is improved significantly. At the same time, the geometric parameters and working parameters of the proposed inductor, including the coil turns, the coil height, the leg length of the magnetic core, the lift-off distance, the working frequency, are researched.
doi_str_mv 10.1016/j.measurement.2021.109063
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_measurement_2021_109063</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0263224121000956</els_id><sourcerecordid>S0263224121000956</sourcerecordid><originalsourceid>FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3</originalsourceid><addsrcrecordid>eNqNkEtLAzEUhYMoWKv_If6AqXl0HllKrQ8ouFFwF9LkZprSmZQkU5l_b4a6cOnqXg7nXM79ELqnZEEJrR72iw5UHAJ00KcFI4xmXZCKX6AZbWpeLCn7ukQzwipeMLak1-gmxj0h2SKqGWqfILq2x6o32PUniMm1KjnfY2-xwunbF9q7A-5U20NyGmsfIDvNoJMPeIhgsM3L2pgR6yGEXAMfh8Okpx2EzrdBHXfjLbqyKqt3v3OOPp_XH6vXYvP-8rZ63BSaM5oKMXW2StCaMJL_aIBCUxpSQt3obWkNmIoy3ojaaNtYqhUpjRZEka3gtFZ8jsT5rg4-xgBWHoPrVBglJXIiJvfyDzE5EZNnYjm7OmchFzw5CDJqB70G4wLoJI13_7jyA3FAfOU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Xiao, Xiang-Tao ; Liang, Zheng ; Zhang, Liang ; Tang, Song</creator><creatorcontrib>Xiao, Xiang-Tao ; Liang, Zheng ; Zhang, Liang ; Tang, Song</creatorcontrib><description>•Proposed a new two-coil magnetic core inductor for ECPT.•Two-coil magnetic core inductor increases the detectable area and visual quality for ECPT.•The uniformity of the temperature distribution on the detection object is improved.•Geometric parameters and the working parameters of the two-coil magnetic core inductor are studied. Eddy current pulse thermography (ECPT) is an active thermography technology in the nondestructive testing field. The inductor of ECPT is an important component that influences detection quality and efficiency. In this paper, a two-coil magnetic core inductor is proposed for ECPT, which characteristics are investigated by numerical simulation methods. This new structure enlarges the detectable area for ECPT and increases the view field for infrared cameras. Research results show that the uniformity of temperature distribution is improved significantly. At the same time, the geometric parameters and working parameters of the proposed inductor, including the coil turns, the coil height, the leg length of the magnetic core, the lift-off distance, the working frequency, are researched.</description><identifier>ISSN: 0263-2241</identifier><identifier>EISSN: 1873-412X</identifier><identifier>DOI: 10.1016/j.measurement.2021.109063</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Detectable area ; ECPT ; Temperature distribution ; Two-coil magnetic core inductor</subject><ispartof>Measurement : journal of the International Measurement Confederation, 2021-04, Vol.174, p.109063, Article 109063</ispartof><rights>2021 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3</citedby><cites>FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids></links><search><creatorcontrib>Xiao, Xiang-Tao</creatorcontrib><creatorcontrib>Liang, Zheng</creatorcontrib><creatorcontrib>Zhang, Liang</creatorcontrib><creatorcontrib>Tang, Song</creatorcontrib><title>Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography</title><title>Measurement : journal of the International Measurement Confederation</title><description>•Proposed a new two-coil magnetic core inductor for ECPT.•Two-coil magnetic core inductor increases the detectable area and visual quality for ECPT.•The uniformity of the temperature distribution on the detection object is improved.•Geometric parameters and the working parameters of the two-coil magnetic core inductor are studied. Eddy current pulse thermography (ECPT) is an active thermography technology in the nondestructive testing field. The inductor of ECPT is an important component that influences detection quality and efficiency. In this paper, a two-coil magnetic core inductor is proposed for ECPT, which characteristics are investigated by numerical simulation methods. This new structure enlarges the detectable area for ECPT and increases the view field for infrared cameras. Research results show that the uniformity of temperature distribution is improved significantly. At the same time, the geometric parameters and working parameters of the proposed inductor, including the coil turns, the coil height, the leg length of the magnetic core, the lift-off distance, the working frequency, are researched.</description><subject>Detectable area</subject><subject>ECPT</subject><subject>Temperature distribution</subject><subject>Two-coil magnetic core inductor</subject><issn>0263-2241</issn><issn>1873-412X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqNkEtLAzEUhYMoWKv_If6AqXl0HllKrQ8ouFFwF9LkZprSmZQkU5l_b4a6cOnqXg7nXM79ELqnZEEJrR72iw5UHAJ00KcFI4xmXZCKX6AZbWpeLCn7ukQzwipeMLak1-gmxj0h2SKqGWqfILq2x6o32PUniMm1KjnfY2-xwunbF9q7A-5U20NyGmsfIDvNoJMPeIhgsM3L2pgR6yGEXAMfh8Okpx2EzrdBHXfjLbqyKqt3v3OOPp_XH6vXYvP-8rZ63BSaM5oKMXW2StCaMJL_aIBCUxpSQt3obWkNmIoy3ojaaNtYqhUpjRZEka3gtFZ8jsT5rg4-xgBWHoPrVBglJXIiJvfyDzE5EZNnYjm7OmchFzw5CDJqB70G4wLoJI13_7jyA3FAfOU</recordid><startdate>202104</startdate><enddate>202104</enddate><creator>Xiao, Xiang-Tao</creator><creator>Liang, Zheng</creator><creator>Zhang, Liang</creator><creator>Tang, Song</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202104</creationdate><title>Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography</title><author>Xiao, Xiang-Tao ; Liang, Zheng ; Zhang, Liang ; Tang, Song</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Detectable area</topic><topic>ECPT</topic><topic>Temperature distribution</topic><topic>Two-coil magnetic core inductor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xiao, Xiang-Tao</creatorcontrib><creatorcontrib>Liang, Zheng</creatorcontrib><creatorcontrib>Zhang, Liang</creatorcontrib><creatorcontrib>Tang, Song</creatorcontrib><collection>CrossRef</collection><jtitle>Measurement : journal of the International Measurement Confederation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xiao, Xiang-Tao</au><au>Liang, Zheng</au><au>Zhang, Liang</au><au>Tang, Song</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography</atitle><jtitle>Measurement : journal of the International Measurement Confederation</jtitle><date>2021-04</date><risdate>2021</risdate><volume>174</volume><spage>109063</spage><pages>109063-</pages><artnum>109063</artnum><issn>0263-2241</issn><eissn>1873-412X</eissn><abstract>•Proposed a new two-coil magnetic core inductor for ECPT.•Two-coil magnetic core inductor increases the detectable area and visual quality for ECPT.•The uniformity of the temperature distribution on the detection object is improved.•Geometric parameters and the working parameters of the two-coil magnetic core inductor are studied. Eddy current pulse thermography (ECPT) is an active thermography technology in the nondestructive testing field. The inductor of ECPT is an important component that influences detection quality and efficiency. In this paper, a two-coil magnetic core inductor is proposed for ECPT, which characteristics are investigated by numerical simulation methods. This new structure enlarges the detectable area for ECPT and increases the view field for infrared cameras. Research results show that the uniformity of temperature distribution is improved significantly. At the same time, the geometric parameters and working parameters of the proposed inductor, including the coil turns, the coil height, the leg length of the magnetic core, the lift-off distance, the working frequency, are researched.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.measurement.2021.109063</doi></addata></record>
fulltext fulltext
identifier ISSN: 0263-2241
ispartof Measurement : journal of the International Measurement Confederation, 2021-04, Vol.174, p.109063, Article 109063
issn 0263-2241
1873-412X
language eng
recordid cdi_crossref_primary_10_1016_j_measurement_2021_109063
source ScienceDirect Freedom Collection 2022-2024
subjects Detectable area
ECPT
Temperature distribution
Two-coil magnetic core inductor
title Design and investigation of a two-coil magnetic core inductor used for Eddy current pulsed thermography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T17%3A49%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20investigation%20of%20a%20two-coil%20magnetic%20core%20inductor%20used%20for%20Eddy%20current%20pulsed%20thermography&rft.jtitle=Measurement%20:%20journal%20of%20the%20International%20Measurement%20Confederation&rft.au=Xiao,%20Xiang-Tao&rft.date=2021-04&rft.volume=174&rft.spage=109063&rft.pages=109063-&rft.artnum=109063&rft.issn=0263-2241&rft.eissn=1873-412X&rft_id=info:doi/10.1016/j.measurement.2021.109063&rft_dat=%3Celsevier_cross%3ES0263224121000956%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c321t-91873fa9170200908e1e85d05e78cb5fded6123897dcf8f1ca05dc90a0b9317a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true