Loading…

Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water

Membrane fouling is an inevitable drawback of the membrane based long-term operations. In this study, we investigated a spontaneous galvanic process for membrane fouling mitigation, which termed as the in-situ galvanic micro-coagulation (GMC) process. Results demonstrated that the GMC contributed to...

Full description

Saved in:
Bibliographic Details
Published in:Journal of membrane science 2020-09, Vol.610, p.118234, Article 118234
Main Authors: Xu, Lei, Wei, Chaocheng, Siddique, Muhammad Saboor, Yu, Wenzheng
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03
cites cdi_FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03
container_end_page
container_issue
container_start_page 118234
container_title Journal of membrane science
container_volume 610
creator Xu, Lei
Wei, Chaocheng
Siddique, Muhammad Saboor
Yu, Wenzheng
description Membrane fouling is an inevitable drawback of the membrane based long-term operations. In this study, we investigated a spontaneous galvanic process for membrane fouling mitigation, which termed as the in-situ galvanic micro-coagulation (GMC) process. Results demonstrated that the GMC contributed to a lower transmembrane pressure development in contrast with the control system (7.15 vs 14.11 KPa/LMH/cP for about 1200 h operation). Significantly, a reduced concentration of extracellular polymeric substances (EPS) in terms of polysaccharides and proteins was observed for the GMC system on both the membrane surface and membrane pores, in comparison with the control system i.e. (134.09 ± 7.37 vs 379.55 ± 9.64 μg/cm2 of polysaccharides and 27.48 ± 2.48 vs 35.87 ± 3.53 μg/cm2 of proteins) and (70.46 ± 1.93 vs 120.46 ± 3.21 μg/cm2 of polysaccharides and 17.96 ± 1.39 vs 20.52 ± 2.12 μg/cm2 of proteins) respectively. Additionally, higher accumulation of EPS on the membrane surface of control system results in higher roughness of biofilm, lower porosity, robust and thicker biopolymer microstructure as compared to the GMC system. This kind of morphology and biofilm structure formed on the membrane surface of control system directly contributed to the higher transmembrane pressure. Overall, this work shows a potentially feasible and promising approach for membrane fouling mitigation, especially for the decentralized system with relatively low permeate flux. [Display omitted] •The in-situ GMC is utilized to alleviate UF membrane fouling for the first time.•GMC can effectively reduce the biopolymers in surface water.•The accumulation of EPS on membrane surface is inhibited by GMC.•GMC leads to a higher porosity biofilm with thinner and slender microstructure.•GMC weakens the interactions between the biofilm and the membrane surface.
doi_str_mv 10.1016/j.memsci.2020.118234
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_memsci_2020_118234</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0376738820308127</els_id><sourcerecordid>S0376738820308127</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03</originalsourceid><addsrcrecordid>eNp9kNtKxDAQhoMouK6-gRd5ga5JU5P0RpDFw8KCN3od0mTSzdI2kqQrvr2Rei0MzPDP6edD6JaSDSWU3x03I4zJ-E1N6iJRWbPmDK2oFKxitGbnaEWY4JVgUl6iq5SOhFBBZLtCaTcl3x8y9lMOOB8Ag3NgMg6uSFXyeca9Hk568gaP3sRQmaD7edDZhwmXKK-7qCfALsyDn_oylX2_tHOEUhQtzdFpA_hLZ4jX6MLpIcHNX16jj-en9-1rtX972W0f95VhhOeqK0aslaJhDiSXHReO21rIVjNSQ6mFZdzoe1K7lmtpdGtEBwwa64gUmrA1apa7xXVKEZz6jH7U8VtRon7BqaNawKlfcGoBV9YeljUo3k4eoioTMBmwPhYyygb__4EfpMh8Vw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water</title><source>Elsevier</source><creator>Xu, Lei ; Wei, Chaocheng ; Siddique, Muhammad Saboor ; Yu, Wenzheng</creator><creatorcontrib>Xu, Lei ; Wei, Chaocheng ; Siddique, Muhammad Saboor ; Yu, Wenzheng</creatorcontrib><description>Membrane fouling is an inevitable drawback of the membrane based long-term operations. In this study, we investigated a spontaneous galvanic process for membrane fouling mitigation, which termed as the in-situ galvanic micro-coagulation (GMC) process. Results demonstrated that the GMC contributed to a lower transmembrane pressure development in contrast with the control system (7.15 vs 14.11 KPa/LMH/cP for about 1200 h operation). Significantly, a reduced concentration of extracellular polymeric substances (EPS) in terms of polysaccharides and proteins was observed for the GMC system on both the membrane surface and membrane pores, in comparison with the control system i.e. (134.09 ± 7.37 vs 379.55 ± 9.64 μg/cm2 of polysaccharides and 27.48 ± 2.48 vs 35.87 ± 3.53 μg/cm2 of proteins) and (70.46 ± 1.93 vs 120.46 ± 3.21 μg/cm2 of polysaccharides and 17.96 ± 1.39 vs 20.52 ± 2.12 μg/cm2 of proteins) respectively. Additionally, higher accumulation of EPS on the membrane surface of control system results in higher roughness of biofilm, lower porosity, robust and thicker biopolymer microstructure as compared to the GMC system. This kind of morphology and biofilm structure formed on the membrane surface of control system directly contributed to the higher transmembrane pressure. Overall, this work shows a potentially feasible and promising approach for membrane fouling mitigation, especially for the decentralized system with relatively low permeate flux. [Display omitted] •The in-situ GMC is utilized to alleviate UF membrane fouling for the first time.•GMC can effectively reduce the biopolymers in surface water.•The accumulation of EPS on membrane surface is inhibited by GMC.•GMC leads to a higher porosity biofilm with thinner and slender microstructure.•GMC weakens the interactions between the biofilm and the membrane surface.</description><identifier>ISSN: 0376-7388</identifier><identifier>EISSN: 1873-3123</identifier><identifier>DOI: 10.1016/j.memsci.2020.118234</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Biofilm microstructure ; Biopolymers ; Galvanic micro-coagulation ; Membrane fouling ; Ultrafiltration</subject><ispartof>Journal of membrane science, 2020-09, Vol.610, p.118234, Article 118234</ispartof><rights>2020 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03</citedby><cites>FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Xu, Lei</creatorcontrib><creatorcontrib>Wei, Chaocheng</creatorcontrib><creatorcontrib>Siddique, Muhammad Saboor</creatorcontrib><creatorcontrib>Yu, Wenzheng</creatorcontrib><title>Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water</title><title>Journal of membrane science</title><description>Membrane fouling is an inevitable drawback of the membrane based long-term operations. In this study, we investigated a spontaneous galvanic process for membrane fouling mitigation, which termed as the in-situ galvanic micro-coagulation (GMC) process. Results demonstrated that the GMC contributed to a lower transmembrane pressure development in contrast with the control system (7.15 vs 14.11 KPa/LMH/cP for about 1200 h operation). Significantly, a reduced concentration of extracellular polymeric substances (EPS) in terms of polysaccharides and proteins was observed for the GMC system on both the membrane surface and membrane pores, in comparison with the control system i.e. (134.09 ± 7.37 vs 379.55 ± 9.64 μg/cm2 of polysaccharides and 27.48 ± 2.48 vs 35.87 ± 3.53 μg/cm2 of proteins) and (70.46 ± 1.93 vs 120.46 ± 3.21 μg/cm2 of polysaccharides and 17.96 ± 1.39 vs 20.52 ± 2.12 μg/cm2 of proteins) respectively. Additionally, higher accumulation of EPS on the membrane surface of control system results in higher roughness of biofilm, lower porosity, robust and thicker biopolymer microstructure as compared to the GMC system. This kind of morphology and biofilm structure formed on the membrane surface of control system directly contributed to the higher transmembrane pressure. Overall, this work shows a potentially feasible and promising approach for membrane fouling mitigation, especially for the decentralized system with relatively low permeate flux. [Display omitted] •The in-situ GMC is utilized to alleviate UF membrane fouling for the first time.•GMC can effectively reduce the biopolymers in surface water.•The accumulation of EPS on membrane surface is inhibited by GMC.•GMC leads to a higher porosity biofilm with thinner and slender microstructure.•GMC weakens the interactions between the biofilm and the membrane surface.</description><subject>Biofilm microstructure</subject><subject>Biopolymers</subject><subject>Galvanic micro-coagulation</subject><subject>Membrane fouling</subject><subject>Ultrafiltration</subject><issn>0376-7388</issn><issn>1873-3123</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kNtKxDAQhoMouK6-gRd5ga5JU5P0RpDFw8KCN3od0mTSzdI2kqQrvr2Rei0MzPDP6edD6JaSDSWU3x03I4zJ-E1N6iJRWbPmDK2oFKxitGbnaEWY4JVgUl6iq5SOhFBBZLtCaTcl3x8y9lMOOB8Ag3NgMg6uSFXyeca9Hk568gaP3sRQmaD7edDZhwmXKK-7qCfALsyDn_oylX2_tHOEUhQtzdFpA_hLZ4jX6MLpIcHNX16jj-en9-1rtX972W0f95VhhOeqK0aslaJhDiSXHReO21rIVjNSQ6mFZdzoe1K7lmtpdGtEBwwa64gUmrA1apa7xXVKEZz6jH7U8VtRon7BqaNawKlfcGoBV9YeljUo3k4eoioTMBmwPhYyygb__4EfpMh8Vw</recordid><startdate>20200901</startdate><enddate>20200901</enddate><creator>Xu, Lei</creator><creator>Wei, Chaocheng</creator><creator>Siddique, Muhammad Saboor</creator><creator>Yu, Wenzheng</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20200901</creationdate><title>Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water</title><author>Xu, Lei ; Wei, Chaocheng ; Siddique, Muhammad Saboor ; Yu, Wenzheng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Biofilm microstructure</topic><topic>Biopolymers</topic><topic>Galvanic micro-coagulation</topic><topic>Membrane fouling</topic><topic>Ultrafiltration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xu, Lei</creatorcontrib><creatorcontrib>Wei, Chaocheng</creatorcontrib><creatorcontrib>Siddique, Muhammad Saboor</creatorcontrib><creatorcontrib>Yu, Wenzheng</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of membrane science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xu, Lei</au><au>Wei, Chaocheng</au><au>Siddique, Muhammad Saboor</au><au>Yu, Wenzheng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water</atitle><jtitle>Journal of membrane science</jtitle><date>2020-09-01</date><risdate>2020</risdate><volume>610</volume><spage>118234</spage><pages>118234-</pages><artnum>118234</artnum><issn>0376-7388</issn><eissn>1873-3123</eissn><abstract>Membrane fouling is an inevitable drawback of the membrane based long-term operations. In this study, we investigated a spontaneous galvanic process for membrane fouling mitigation, which termed as the in-situ galvanic micro-coagulation (GMC) process. Results demonstrated that the GMC contributed to a lower transmembrane pressure development in contrast with the control system (7.15 vs 14.11 KPa/LMH/cP for about 1200 h operation). Significantly, a reduced concentration of extracellular polymeric substances (EPS) in terms of polysaccharides and proteins was observed for the GMC system on both the membrane surface and membrane pores, in comparison with the control system i.e. (134.09 ± 7.37 vs 379.55 ± 9.64 μg/cm2 of polysaccharides and 27.48 ± 2.48 vs 35.87 ± 3.53 μg/cm2 of proteins) and (70.46 ± 1.93 vs 120.46 ± 3.21 μg/cm2 of polysaccharides and 17.96 ± 1.39 vs 20.52 ± 2.12 μg/cm2 of proteins) respectively. Additionally, higher accumulation of EPS on the membrane surface of control system results in higher roughness of biofilm, lower porosity, robust and thicker biopolymer microstructure as compared to the GMC system. This kind of morphology and biofilm structure formed on the membrane surface of control system directly contributed to the higher transmembrane pressure. Overall, this work shows a potentially feasible and promising approach for membrane fouling mitigation, especially for the decentralized system with relatively low permeate flux. [Display omitted] •The in-situ GMC is utilized to alleviate UF membrane fouling for the first time.•GMC can effectively reduce the biopolymers in surface water.•The accumulation of EPS on membrane surface is inhibited by GMC.•GMC leads to a higher porosity biofilm with thinner and slender microstructure.•GMC weakens the interactions between the biofilm and the membrane surface.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.memsci.2020.118234</doi></addata></record>
fulltext fulltext
identifier ISSN: 0376-7388
ispartof Journal of membrane science, 2020-09, Vol.610, p.118234, Article 118234
issn 0376-7388
1873-3123
language eng
recordid cdi_crossref_primary_10_1016_j_memsci_2020_118234
source Elsevier
subjects Biofilm microstructure
Biopolymers
Galvanic micro-coagulation
Membrane fouling
Ultrafiltration
title Insight into the effect of in-situ galvanic micro-coagulation on membrane fouling mitigation treating surface water
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T09%3A32%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Insight%20into%20the%20effect%20of%20in-situ%20galvanic%20micro-coagulation%20on%20membrane%20fouling%20mitigation%20treating%20surface%20water&rft.jtitle=Journal%20of%20membrane%20science&rft.au=Xu,%20Lei&rft.date=2020-09-01&rft.volume=610&rft.spage=118234&rft.pages=118234-&rft.artnum=118234&rft.issn=0376-7388&rft.eissn=1873-3123&rft_id=info:doi/10.1016/j.memsci.2020.118234&rft_dat=%3Celsevier_cross%3ES0376738820308127%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c306t-bffedd8743fe868b67f6d2789a302ef6d7d36ca502f96a8ca9c7be3e4df087a03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true