Loading…
Electrostatically-driven self-assembly of copper nanoclusters and carbon dots for quantitative protamine and heparin determination
[Display omitted] •Thiolate-capped CuNCs with aggregation-induced emission property were synthesized.•Blue emissive cationic carbon dots (B-CDs+) were hydrothermally prepared.•Ratiometric detection of protamine and heparin was carried out.•Protamine quenched fluorescence of GSH-CuNCs at 590 nm, whil...
Saved in:
Published in: | Microchemical journal 2023-12, Vol.195, p.109404, Article 109404 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | [Display omitted]
•Thiolate-capped CuNCs with aggregation-induced emission property were synthesized.•Blue emissive cationic carbon dots (B-CDs+) were hydrothermally prepared.•Ratiometric detection of protamine and heparin was carried out.•Protamine quenched fluorescence of GSH-CuNCs at 590 nm, while B-CDs+ emission at 470 nm was not affected.•Heparin can recover the fluorescence emission of B-CDs+/ GSH-CuNCs.
A novel nanosystem composed of red-emissive thiolate-capped copper nanoclusters (GSH-CuNCs) and blue-emissive polyethyleneimine-tailored carbon dots (B-CDs+) was utilized for the quantitative determination of protamine and heparin. Addition of B-CDs+ to a solution containing GSH-CuNCs resulted in a significant increase in the fluorescence emission of GSH-CuNCs due to their self-assembly through an electrostatic interaction. However, in the presence of protamine, a polycationic protein, the fluorescence emission of GSH-CuNCs at 590 nm was decreased as a result of adsorbing protamine on GSH-CuNCs surface instead of B-CDs+. This led to disassembling of GSH-CuNCs, while the fluorescence emission of B-CDs+ at 470 nm remained unchanged during the determination. In the presence of heparin, a negatively charged molecule, the fluorescence emission of GSH-CuNCs nanosystem was recovered due to strong electrostatic interaction between protamine and heparin. The displaced B-CDs+ aggregated the GSH-CuNCs, restoring its fluorescence emission. Under optimized conditions, the fluorescence responses were increased with the protamine and heparin concentrations in the range of 0.004–40 µg/mL and 0.01–28 µg/mL, with LODs (S/N = 3) of 0.001 µg/mL and 0.004 µg/mL, respectively. The nanosystem offers several merits, including an ultra-low LODs, wide dynamic linear range, good anti-interference, satisfactory detection reliability, and short response time. Importantly, this strategy was successfully devoted to estimate protamine and heparin in urine and serum samples, and the results were found to be acceptable. |
---|---|
ISSN: | 0026-265X 1095-9149 |
DOI: | 10.1016/j.microc.2023.109404 |