Loading…
Toward standardization of low impedance contact CDM
The 16.6 Ω implementation of contact CDM (LICCDM) recently published in ANSI-ESD Standard Practice 5.3.3 is shown to produce waveforms of similar shape, Ifail, and Ipeak vs. CDUT dependency as JS-002. The non-monotonicity of JS-002 at low voltages is overcome using LICCDM. A path to joint standardiz...
Saved in:
Published in: | Microelectronics and reliability 2021-01, Vol.116, p.114011, Article 114011 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The 16.6 Ω implementation of contact CDM (LICCDM) recently published in ANSI-ESD Standard Practice 5.3.3 is shown to produce waveforms of similar shape, Ifail, and Ipeak vs. CDUT dependency as JS-002. The non-monotonicity of JS-002 at low voltages is overcome using LICCDM. A path to joint standardization with air discharge testing is proposed. |
---|---|
ISSN: | 0026-2714 1872-941X |
DOI: | 10.1016/j.microrel.2020.114011 |