Toward standardization of low impedance contact CDM

The 16.6 Ω implementation of contact CDM (LICCDM) recently published in ANSI-ESD Standard Practice 5.3.3 is shown to produce waveforms of similar shape, Ifail, and Ipeak vs. CDUT dependency as JS-002. The non-monotonicity of JS-002 at low voltages is overcome using LICCDM. A path to joint standardiz...

Full description

Saved in:
Bibliographic Details
Published in:Microelectronics and reliability 2021-01, Vol.116, p.114011, Article 114011
Main Authors: Jack, Nathan, Carn, Brett, Morris, Josh
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The 16.6 Ω implementation of contact CDM (LICCDM) recently published in ANSI-ESD Standard Practice 5.3.3 is shown to produce waveforms of similar shape, Ifail, and Ipeak vs. CDUT dependency as JS-002. The non-monotonicity of JS-002 at low voltages is overcome using LICCDM. A path to joint standardization with air discharge testing is proposed.