Unconstrained blood pressure monitoring based on a neural network–assisted multistage pressure textile sensor

Non-invasive blood pressure (NIBP) assessment via constrained wearable devices aided by intelligent algorithms has led to tremendous advancements in healthcare. However, existing NIBP assessment methods generally impose hard constraints on human behavior, resulting in lower accuracy of blood pressur...

Full description

Saved in:
Bibliographic Details
Published in:Nano energy 2023-10, Vol.115, p.108730, Article 108730
Main Authors: Si, Shaobo, Sun, Chenchen, Wang, Han, Wu, Hongbing, Chen, Lilin, Xia, Yushu, Qin, Jianchao, Wu, Yufen, Yang, Jin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Non-invasive blood pressure (NIBP) assessment via constrained wearable devices aided by intelligent algorithms has led to tremendous advancements in healthcare. However, existing NIBP assessment methods generally impose hard constraints on human behavior, resulting in lower accuracy of blood pressure assessments. Therefore, for unconstrained ambulatory blood pressure monitoring, we propose a textile-based sensor with a multistage structure that acquires human ballistocardiogram (BCG) signals. Using nylon fabric as a substrate, a multistage structure consisting of sensitive micro-cilia and nylon supports ensures that the sensor maintains high sensitivity (0.533 V/kPa) even under static pressure (0–7 kPa) equal to the self-weight of the human body. The BCG waves acquired by the sensor have excellent agreement with the cardiac vibration wave obtained with laser vibrometry (displacement precision of 0.5 pm). Benefiting from the accurate acquisition of BCG, the time interval between each characteristic point of BCG waves is independently used as the characteristic parameter. A blood pressure assessment model via a back-propagation neural network is proposed to realize an unconstrained blood pressure assessment. For unconstrained measurements of diastolic pressure (DP) and systolic pressure (SP), the mean absolute error and standard deviation of error were 3.90 ± 4.79 mmHg and 4.62 ± 6.00 mmHg, respectively; this result meets the accuracy criteria of the American Association for the Advancement of Medical Instrumentation for Class II medical. We propose a new approach for unconstrained ambulatory blood pressure monitoring that shows great potential in home, hospital, and personalized medicine. [Display omitted] •The TMSS has the advantage of high sensitivity (0.533 V/kPa) under static pressure (0–7 kPa) equal to the self-weight of the human body.•The BCG signal acquisition system is completely independent of electrodes, stents, and other auxiliary medical equipment on human behavior.•BCG signals by TMSSs for blood pressure measurement with the accuracy that meets the accuracy criteria of the AAMI for Class II Medical.
ISSN:2211-2855
DOI:10.1016/j.nanoen.2023.108730