Light output response of BC-505 liquid scintillator

Data on the light output response of BC-505 liquid scintillator to neutrons ranging in energy from 0.5 to 12 MeV have been fitted with the parameterization of Chou using the GEANT4 toolkit to simulate the response of the scintillators. Excellent agreement is obtained with the parameters kB = 0.0061...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2006-09, Vol.565 (2), p.725-730
Main Authors: Pywell, R.E., Sawatzky, B.D., Ives, J., Kolb, N.R., Igarashi, R., Wurtz, W.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Data on the light output response of BC-505 liquid scintillator to neutrons ranging in energy from 0.5 to 12 MeV have been fitted with the parameterization of Chou using the GEANT4 toolkit to simulate the response of the scintillators. Excellent agreement is obtained with the parameters kB = 0.0061 ± 0.0003 g cm - 2 MeV - 1 and C = ( 1.0 ± 0.1 ) × 10 - 5 g 2 cm - 4 MeV - 2 .