Loading…

Evaluation of high grid strip densities based on the moiré artifact analysis for quality assurance: Simulation and experiment

We have recently developed precise x-ray grids having strip densities in the range of 100 – 250 lines/inch by adopting the precision sawing process and carbon interspace material for the demands of specific x-ray imaging techniques. However, quality assurance in the grid manufacturing has not yet sa...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2017-09, Vol.866, p.58-64
Main Authors: Je, U.K., Park, C.K., Lim, H.W., Cho, H.S., Lee, D.Y., Lee, H.W., Kim, K.S., Park, S.Y., Kim, G.A., Kang, S.Y., Park, J.E., Kim, W.S., Jeon, D.H., Woo, T.H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We have recently developed precise x-ray grids having strip densities in the range of 100 – 250 lines/inch by adopting the precision sawing process and carbon interspace material for the demands of specific x-ray imaging techniques. However, quality assurance in the grid manufacturing has not yet satisfactorily conducted because grid strips of a high strip density are often invisible through an x-ray nondestructive testing with a flat-panel detector of an ordinary pixel resolution (>100 μm). In this work, we propose a useful method to evaluate actual grid strip densities over the Nyquist sampling rate based on the moiré artifact analysis. We performed a systematic simulation and experiment with several sample grids and a detector having a 143-μm pixel resolution to verify the proposed quality assurance method. According to our results, the relative differences between the nominal and the evaluated grid strip densities were within 0.2% and 1.8% in the simulation and experiment, respectively, which demonstrates that the proposed method is viable with an ordinary detector having a moderate pixel resolution for quality assurance in grid manufacturing. •The precise carbon-interspaced antiscatter grids have been studied.•It is proposed for a useful method to evaluate actual grid strip densities over the Nyquist sampling rate based on the moiré artifact analysis.•The simulation and experimental results demonstrate that the proposed method is viable with an ordinary detector having a moderate pixel resolution (>100 μm) for quality assurance in grid manufacturing.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2017.06.001