Survivability of microstructure semiconductor neutron detectors (MSND) in a thermal neutron radiation environment

The performance of five representative microstructured semiconductor neutron detectors (MSND) were investigated after exposure to varying magnitudes of thermal neutrons fluences ranging from 107 cm−2 to 1012 n cm−2. The devices have 95% enriched microparticulate 6LiF granules backfilled in microscop...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2023-12, Vol.1057, p.168721, Article 168721
Main Authors: Hutchins, R.M., Watson, D.L.P., Nichols, D.M., Sieh, B.M., McGregor, D.S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The performance of five representative microstructured semiconductor neutron detectors (MSND) were investigated after exposure to varying magnitudes of thermal neutrons fluences ranging from 107 cm−2 to 1012 n cm−2. The devices have 95% enriched microparticulate 6LiF granules backfilled in microscopic trenches within a Si pvn diode. Neutron interactions in the 6Li causes the emission of reaction products which ionize the trenched Si diode depletion regions. The average intrinsic thermal-neutron detection efficiency (ϵtn) of the five devices before irradiation measured as 24.09% ± 0.35% with an operating leakage current below 11 nA at a −3 V reverse bias condition. The observed threshold of performance deterioration was approximately 1010 n cm−2, resulting in an spectral shift in the reaction product spectrum to lower energy channels and a general increase in leakage current. Although damage was observed beyond a thermal-neutron fluence of 1010 n cm−2, the devices remained operable. Beyond a thermal-neutron fluence of 1012 n cm−2, the devices experienced severe damage and demonstrated poor detector performance. At the highest thermal neutron fluences tested, near 1012 n cm−2, the average ϵtn of the five devices decreased to 4.42% ± 0.10% with an average operating leakage current of 300 nA at a −3 V reverse bias condition. Performance degradation was attributed to reaction-product damage in the MSND pvn diode structure.