Loading…

Removal of straylight from ExoMars NOMAD-UVIS observations

We present an in-flight straylight removal method for the Ultraviolet and Visible Spectrometer (UVIS) channel of the Nadir and Occultation for Mars Discovery (NOMAD) instrument aboard the ExoMars Trace Gas Orbiter (TGO). The presence of a ‘red-leak’ straylight signal in the UVIS instrument was disco...

Full description

Saved in:
Bibliographic Details
Published in:Planetary and space science 2022-09, Vol.218, p.105432, Article 105432
Main Authors: Mason, Jonathon P., Patel, Manish R., Leese, Mark R., Hathi, Brijen G., Willame, Yannick, Thomas, Ian R., Wolff, Michael J., Depiesse, Cédric, Holmes, James A., Sellers, Graham, Marriner, Charlotte, Ristic, Bojan, Daerden, Frank, Lopez-Moreno, Jose Juan, Bellucci, Giancarlo, Vandaele, Ann Carine
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present an in-flight straylight removal method for the Ultraviolet and Visible Spectrometer (UVIS) channel of the Nadir and Occultation for Mars Discovery (NOMAD) instrument aboard the ExoMars Trace Gas Orbiter (TGO). The presence of a ‘red-leak’ straylight signal in the UVIS instrument was discovered post-launch in ground calibration measurements of spectral lamps; UVIS observations of lamps with negligible UV light emission (RS12) showed a significant signal at UV wavelengths. Subsequent analyses of nadir observations of the martian atmosphere revealed that at UV wavelengths the red-leak straylight was in excess of 300% of the true UV signal, jeopardising the primary science observations of the instrument (retrievals of atmospheric ozone). By modifying the UVIS readout method to obtain a region of interest around the illuminated region on the Charge-Coupled Device (CCD) detector, instead of a binned one-dimensional spectrum, and utilising straylight profiles derived from measurements of the RS12 calibration lamp we show that the majority of the straylight at UV wavelengths can be successfully removed for the nadir channel in a self-consistent manner. The corrected UVIS radiances are compared to coincident Mars Color Imager (MARCI) instrument observations with residuals between the two instruments generally remaining within 15%. •Retaining the full CCD array can be a powerful tool for the removal of straylight.•Essential to measure straylight profiles using different light sources and filters.•Accurate removal of straylight and recovery of measured ultraviolet radiances.
ISSN:0032-0633
1873-5088
DOI:10.1016/j.pss.2022.105432