Loading…

TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry

TL dosimetric characteristics of glass screen protectors were analyzed for radiation accident dosimetry. Radiation-induced TL signal and intrinsic background signal of these glasses were investigated. An attempt to categorize the glasses according to the shape of their radiation-induced TL glow curv...

Full description

Saved in:
Bibliographic Details
Published in:Radiation measurements 2020-08, Vol.136, p.106384, Article 106384
Main Authors: Bassinet, Céline, Le Bris, Wendy
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03
cites cdi_FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03
container_end_page
container_issue
container_start_page 106384
container_title Radiation measurements
container_volume 136
creator Bassinet, Céline
Le Bris, Wendy
description TL dosimetric characteristics of glass screen protectors were analyzed for radiation accident dosimetry. Radiation-induced TL signal and intrinsic background signal of these glasses were investigated. An attempt to categorize the glasses according to the shape of their radiation-induced TL glow curve was made. Then, the main dosimetric properties were studied for a category of glass. Radiation-induced TL signal was light sensitive and TL measurements were done on the hard-to-bleach component of the TL signal after bleaching with blue LEDs. The sensitization was negligible after 5 cycles “irradiation – pre-bleaching – TL measurement”. The dose response was linear up to 20 Gy. Fading was negligible up to 100 h and limited to ~20% for the investigated time range of 12 days. The results of a dose recovery test were promising. These preliminary results are interesting, but further studies on a larger set of screen protectors are needed to really appreciate the potential of glass extracted from mobile phone screen protectors to be used as fortuitous retrospective dosimeter in the event of a radiological accident. •TL dosimetric properties of glasses extracted from screen protectors for mobile phones are investigated.•Preliminary results appear to be promising for radiation accident dosimetry.•The effect of daylight on the radio-induced TL signal needs to be studied.
doi_str_mv 10.1016/j.radmeas.2020.106384
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_radmeas_2020_106384</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1350448720301633</els_id><sourcerecordid>S1350448720301633</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03</originalsourceid><addsrcrecordid>eNqFkNtKAzEQhoMoWKuPIOQFtia72c3mSqR4goI39TqmyUxN6W5KEgp9e1O2917NMPP_c_gIeeRswRnvnnaLaNwAJi1qVp9rXdOLKzLjvVQVU3V7XfKmZZUQvbwldyntGGNCde2M_KxX1I9HSNlvTfZhpAHpdm9SgkQxhoEOYeP3QA-_YQSabAQY6SGGDDaHWDQh0rLeT2ZjrXcwZupC8gPkeLonN2j2CR4ucU6-317Xy49q9fX-uXxZVbZRLFdcSGWQy5qjRO4cYG_bxmKtFKIzLdoeSsuglJw5YYxgqgg7VBtpG2TNnLTTXBtDShFQH6IfTDxpzvQZk97pCyZ9xqQnTMX3PPmgHHf0EHWyHkYLzsfyonbB_zPhDy3udpY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry</title><source>Elsevier</source><creator>Bassinet, Céline ; Le Bris, Wendy</creator><creatorcontrib>Bassinet, Céline ; Le Bris, Wendy</creatorcontrib><description>TL dosimetric characteristics of glass screen protectors were analyzed for radiation accident dosimetry. Radiation-induced TL signal and intrinsic background signal of these glasses were investigated. An attempt to categorize the glasses according to the shape of their radiation-induced TL glow curve was made. Then, the main dosimetric properties were studied for a category of glass. Radiation-induced TL signal was light sensitive and TL measurements were done on the hard-to-bleach component of the TL signal after bleaching with blue LEDs. The sensitization was negligible after 5 cycles “irradiation – pre-bleaching – TL measurement”. The dose response was linear up to 20 Gy. Fading was negligible up to 100 h and limited to ~20% for the investigated time range of 12 days. The results of a dose recovery test were promising. These preliminary results are interesting, but further studies on a larger set of screen protectors are needed to really appreciate the potential of glass extracted from mobile phone screen protectors to be used as fortuitous retrospective dosimeter in the event of a radiological accident. •TL dosimetric properties of glasses extracted from screen protectors for mobile phones are investigated.•Preliminary results appear to be promising for radiation accident dosimetry.•The effect of daylight on the radio-induced TL signal needs to be studied.</description><identifier>ISSN: 1350-4487</identifier><identifier>EISSN: 1879-0925</identifier><identifier>DOI: 10.1016/j.radmeas.2020.106384</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Emergency dosimeter ; Glass screen protector ; Mobile phones ; Radiological accident ; Retrospective dosimetry ; Thermoluminescence</subject><ispartof>Radiation measurements, 2020-08, Vol.136, p.106384, Article 106384</ispartof><rights>2020 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03</citedby><cites>FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03</cites><orcidid>0000-0002-5642-2208</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Bassinet, Céline</creatorcontrib><creatorcontrib>Le Bris, Wendy</creatorcontrib><title>TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry</title><title>Radiation measurements</title><description>TL dosimetric characteristics of glass screen protectors were analyzed for radiation accident dosimetry. Radiation-induced TL signal and intrinsic background signal of these glasses were investigated. An attempt to categorize the glasses according to the shape of their radiation-induced TL glow curve was made. Then, the main dosimetric properties were studied for a category of glass. Radiation-induced TL signal was light sensitive and TL measurements were done on the hard-to-bleach component of the TL signal after bleaching with blue LEDs. The sensitization was negligible after 5 cycles “irradiation – pre-bleaching – TL measurement”. The dose response was linear up to 20 Gy. Fading was negligible up to 100 h and limited to ~20% for the investigated time range of 12 days. The results of a dose recovery test were promising. These preliminary results are interesting, but further studies on a larger set of screen protectors are needed to really appreciate the potential of glass extracted from mobile phone screen protectors to be used as fortuitous retrospective dosimeter in the event of a radiological accident. •TL dosimetric properties of glasses extracted from screen protectors for mobile phones are investigated.•Preliminary results appear to be promising for radiation accident dosimetry.•The effect of daylight on the radio-induced TL signal needs to be studied.</description><subject>Emergency dosimeter</subject><subject>Glass screen protector</subject><subject>Mobile phones</subject><subject>Radiological accident</subject><subject>Retrospective dosimetry</subject><subject>Thermoluminescence</subject><issn>1350-4487</issn><issn>1879-0925</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqFkNtKAzEQhoMoWKuPIOQFtia72c3mSqR4goI39TqmyUxN6W5KEgp9e1O2917NMPP_c_gIeeRswRnvnnaLaNwAJi1qVp9rXdOLKzLjvVQVU3V7XfKmZZUQvbwldyntGGNCde2M_KxX1I9HSNlvTfZhpAHpdm9SgkQxhoEOYeP3QA-_YQSabAQY6SGGDDaHWDQh0rLeT2ZjrXcwZupC8gPkeLonN2j2CR4ucU6-317Xy49q9fX-uXxZVbZRLFdcSGWQy5qjRO4cYG_bxmKtFKIzLdoeSsuglJw5YYxgqgg7VBtpG2TNnLTTXBtDShFQH6IfTDxpzvQZk97pCyZ9xqQnTMX3PPmgHHf0EHWyHkYLzsfyonbB_zPhDy3udpY</recordid><startdate>20200801</startdate><enddate>20200801</enddate><creator>Bassinet, Céline</creator><creator>Le Bris, Wendy</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-5642-2208</orcidid></search><sort><creationdate>20200801</creationdate><title>TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry</title><author>Bassinet, Céline ; Le Bris, Wendy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Emergency dosimeter</topic><topic>Glass screen protector</topic><topic>Mobile phones</topic><topic>Radiological accident</topic><topic>Retrospective dosimetry</topic><topic>Thermoluminescence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bassinet, Céline</creatorcontrib><creatorcontrib>Le Bris, Wendy</creatorcontrib><collection>CrossRef</collection><jtitle>Radiation measurements</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bassinet, Céline</au><au>Le Bris, Wendy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry</atitle><jtitle>Radiation measurements</jtitle><date>2020-08-01</date><risdate>2020</risdate><volume>136</volume><spage>106384</spage><pages>106384-</pages><artnum>106384</artnum><issn>1350-4487</issn><eissn>1879-0925</eissn><abstract>TL dosimetric characteristics of glass screen protectors were analyzed for radiation accident dosimetry. Radiation-induced TL signal and intrinsic background signal of these glasses were investigated. An attempt to categorize the glasses according to the shape of their radiation-induced TL glow curve was made. Then, the main dosimetric properties were studied for a category of glass. Radiation-induced TL signal was light sensitive and TL measurements were done on the hard-to-bleach component of the TL signal after bleaching with blue LEDs. The sensitization was negligible after 5 cycles “irradiation – pre-bleaching – TL measurement”. The dose response was linear up to 20 Gy. Fading was negligible up to 100 h and limited to ~20% for the investigated time range of 12 days. The results of a dose recovery test were promising. These preliminary results are interesting, but further studies on a larger set of screen protectors are needed to really appreciate the potential of glass extracted from mobile phone screen protectors to be used as fortuitous retrospective dosimeter in the event of a radiological accident. •TL dosimetric properties of glasses extracted from screen protectors for mobile phones are investigated.•Preliminary results appear to be promising for radiation accident dosimetry.•The effect of daylight on the radio-induced TL signal needs to be studied.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.radmeas.2020.106384</doi><orcidid>https://orcid.org/0000-0002-5642-2208</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1350-4487
ispartof Radiation measurements, 2020-08, Vol.136, p.106384, Article 106384
issn 1350-4487
1879-0925
language eng
recordid cdi_crossref_primary_10_1016_j_radmeas_2020_106384
source Elsevier
subjects Emergency dosimeter
Glass screen protector
Mobile phones
Radiological accident
Retrospective dosimetry
Thermoluminescence
title TL investigation of glasses from mobile phone screen protectors for radiation accident dosimetry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T23%3A06%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=TL%20investigation%20of%20glasses%20from%20mobile%20phone%20screen%20protectors%20for%20radiation%20accident%20dosimetry&rft.jtitle=Radiation%20measurements&rft.au=Bassinet,%20C%C3%A9line&rft.date=2020-08-01&rft.volume=136&rft.spage=106384&rft.pages=106384-&rft.artnum=106384&rft.issn=1350-4487&rft.eissn=1879-0925&rft_id=info:doi/10.1016/j.radmeas.2020.106384&rft_dat=%3Celsevier_cross%3ES1350448720301633%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c390t-1479af1721f7f1ddef8c53cf299ffda5fc8e1f7af7710d4aa4097f16f9b7c3f03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true