Loading…

Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field

The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity γ-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of γ-ray dosimeter is required for the quality assurance...

Full description

Saved in:
Bibliographic Details
Published in:Radiation measurements 2023-02, Vol.161, p.106900, Article 106900
Main Authors: Matsubayashi, Nishiki, Hu, Naonori, Takata, Takushi, Sasaki, Akinori, Mukawa, Tetsuya, Suga, Keita, Sakurai, Yoshinori, Tanaka, Hiroki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643
cites cdi_FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643
container_end_page
container_issue
container_start_page 106900
container_title Radiation measurements
container_volume 161
creator Matsubayashi, Nishiki
Hu, Naonori
Takata, Takushi
Sasaki, Akinori
Mukawa, Tetsuya
Suga, Keita
Sakurai, Yoshinori
Tanaka, Hiroki
description The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity γ-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of γ-ray dosimeter is required for the quality assurance (QA) of the treatment. Therefore, in this study, an optically stimulated luminescent dosimeter (OSLD) made of BeO ceramic was selected and its use in the field of BNCT was investigated. The performance of the dosimeter was tested and the effect of a thermal neutron on the γ-ray dose obtained by the OSLD was measured. The OSLDs had a good γ-ray dose linearity of approximately 300 mGy corresponding to the dose in the quality assurance procedure of BNCT, and the thermal neutron sensitivity of the OSLD was less than that of TLD. •This study aims at analyzing the characteristics of OSLD of beryllium oxide in BNCT irradiation field.•The performance of the dosimeters was tested and the influence of thermal neutron on the γ-ray dose was measured.•The OSLD signal was confirmed to have a lower thermal neutron sensitivity than TLD that have been used for BNCT.•It was confirmed that the OSLD can be used in BNCT irradiation field.
doi_str_mv 10.1016/j.radmeas.2023.106900
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_radmeas_2023_106900</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S135044872300001X</els_id><sourcerecordid>S135044872300001X</sourcerecordid><originalsourceid>FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643</originalsourceid><addsrcrecordid>eNqFkM1KAzEUhYMoWKuPIOQFpmaSSdqsRAf_oOimrkMmucFbMjMlmYp9e1Pq3tU9HO45HD5Cbmu2qFmt7raLZH0PNi8446J4SjN2Rmb1aqkrprk8L1pIVjXNanlJrnLeMsYareSMbNsvm6ybIGGe0GU6BjruirIxHmix-n20E3ga9z0OkB0ME_Vjxh5K5vjdQTrEiPuejj_ogeJAH9_bDcVUVqGdcBxoQIj-mlwEGzPc_N05-Xx-2rSv1frj5a19WFdOMD1VnRSBOye18zZwoTolnBVCaFkrxR1feRVA81oIz6TutLVaB9mFrgjZqUbMiTz1ujTmnCCYXcLepoOpmTkCM1vzB8wcgZkTsJK7P-WgjPtGSCY7hMGBxwRuMn7Efxp-AVCReZ0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field</title><source>ScienceDirect Freedom Collection</source><creator>Matsubayashi, Nishiki ; Hu, Naonori ; Takata, Takushi ; Sasaki, Akinori ; Mukawa, Tetsuya ; Suga, Keita ; Sakurai, Yoshinori ; Tanaka, Hiroki</creator><creatorcontrib>Matsubayashi, Nishiki ; Hu, Naonori ; Takata, Takushi ; Sasaki, Akinori ; Mukawa, Tetsuya ; Suga, Keita ; Sakurai, Yoshinori ; Tanaka, Hiroki</creatorcontrib><description>The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity γ-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of γ-ray dosimeter is required for the quality assurance (QA) of the treatment. Therefore, in this study, an optically stimulated luminescent dosimeter (OSLD) made of BeO ceramic was selected and its use in the field of BNCT was investigated. The performance of the dosimeter was tested and the effect of a thermal neutron on the γ-ray dose obtained by the OSLD was measured. The OSLDs had a good γ-ray dose linearity of approximately 300 mGy corresponding to the dose in the quality assurance procedure of BNCT, and the thermal neutron sensitivity of the OSLD was less than that of TLD. •This study aims at analyzing the characteristics of OSLD of beryllium oxide in BNCT irradiation field.•The performance of the dosimeters was tested and the influence of thermal neutron on the γ-ray dose was measured.•The OSLD signal was confirmed to have a lower thermal neutron sensitivity than TLD that have been used for BNCT.•It was confirmed that the OSLD can be used in BNCT irradiation field.</description><identifier>ISSN: 1350-4487</identifier><identifier>EISSN: 1879-0925</identifier><identifier>DOI: 10.1016/j.radmeas.2023.106900</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Beryllium oxide ; BNCT ; Boron neutron capture therapy ; Optically stimulated luminescent dosimeter ; OSLD</subject><ispartof>Radiation measurements, 2023-02, Vol.161, p.106900, Article 106900</ispartof><rights>2023 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643</citedby><cites>FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643</cites><orcidid>0000-0002-6195-3177</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Matsubayashi, Nishiki</creatorcontrib><creatorcontrib>Hu, Naonori</creatorcontrib><creatorcontrib>Takata, Takushi</creatorcontrib><creatorcontrib>Sasaki, Akinori</creatorcontrib><creatorcontrib>Mukawa, Tetsuya</creatorcontrib><creatorcontrib>Suga, Keita</creatorcontrib><creatorcontrib>Sakurai, Yoshinori</creatorcontrib><creatorcontrib>Tanaka, Hiroki</creatorcontrib><title>Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field</title><title>Radiation measurements</title><description>The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity γ-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of γ-ray dosimeter is required for the quality assurance (QA) of the treatment. Therefore, in this study, an optically stimulated luminescent dosimeter (OSLD) made of BeO ceramic was selected and its use in the field of BNCT was investigated. The performance of the dosimeter was tested and the effect of a thermal neutron on the γ-ray dose obtained by the OSLD was measured. The OSLDs had a good γ-ray dose linearity of approximately 300 mGy corresponding to the dose in the quality assurance procedure of BNCT, and the thermal neutron sensitivity of the OSLD was less than that of TLD. •This study aims at analyzing the characteristics of OSLD of beryllium oxide in BNCT irradiation field.•The performance of the dosimeters was tested and the influence of thermal neutron on the γ-ray dose was measured.•The OSLD signal was confirmed to have a lower thermal neutron sensitivity than TLD that have been used for BNCT.•It was confirmed that the OSLD can be used in BNCT irradiation field.</description><subject>Beryllium oxide</subject><subject>BNCT</subject><subject>Boron neutron capture therapy</subject><subject>Optically stimulated luminescent dosimeter</subject><subject>OSLD</subject><issn>1350-4487</issn><issn>1879-0925</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqFkM1KAzEUhYMoWKuPIOQFpmaSSdqsRAf_oOimrkMmucFbMjMlmYp9e1Pq3tU9HO45HD5Cbmu2qFmt7raLZH0PNi8446J4SjN2Rmb1aqkrprk8L1pIVjXNanlJrnLeMsYareSMbNsvm6ybIGGe0GU6BjruirIxHmix-n20E3ga9z0OkB0ME_Vjxh5K5vjdQTrEiPuejj_ogeJAH9_bDcVUVqGdcBxoQIj-mlwEGzPc_N05-Xx-2rSv1frj5a19WFdOMD1VnRSBOye18zZwoTolnBVCaFkrxR1feRVA81oIz6TutLVaB9mFrgjZqUbMiTz1ujTmnCCYXcLepoOpmTkCM1vzB8wcgZkTsJK7P-WgjPtGSCY7hMGBxwRuMn7Efxp-AVCReZ0</recordid><startdate>202302</startdate><enddate>202302</enddate><creator>Matsubayashi, Nishiki</creator><creator>Hu, Naonori</creator><creator>Takata, Takushi</creator><creator>Sasaki, Akinori</creator><creator>Mukawa, Tetsuya</creator><creator>Suga, Keita</creator><creator>Sakurai, Yoshinori</creator><creator>Tanaka, Hiroki</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-6195-3177</orcidid></search><sort><creationdate>202302</creationdate><title>Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field</title><author>Matsubayashi, Nishiki ; Hu, Naonori ; Takata, Takushi ; Sasaki, Akinori ; Mukawa, Tetsuya ; Suga, Keita ; Sakurai, Yoshinori ; Tanaka, Hiroki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Beryllium oxide</topic><topic>BNCT</topic><topic>Boron neutron capture therapy</topic><topic>Optically stimulated luminescent dosimeter</topic><topic>OSLD</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Matsubayashi, Nishiki</creatorcontrib><creatorcontrib>Hu, Naonori</creatorcontrib><creatorcontrib>Takata, Takushi</creatorcontrib><creatorcontrib>Sasaki, Akinori</creatorcontrib><creatorcontrib>Mukawa, Tetsuya</creatorcontrib><creatorcontrib>Suga, Keita</creatorcontrib><creatorcontrib>Sakurai, Yoshinori</creatorcontrib><creatorcontrib>Tanaka, Hiroki</creatorcontrib><collection>CrossRef</collection><jtitle>Radiation measurements</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Matsubayashi, Nishiki</au><au>Hu, Naonori</au><au>Takata, Takushi</au><au>Sasaki, Akinori</au><au>Mukawa, Tetsuya</au><au>Suga, Keita</au><au>Sakurai, Yoshinori</au><au>Tanaka, Hiroki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field</atitle><jtitle>Radiation measurements</jtitle><date>2023-02</date><risdate>2023</risdate><volume>161</volume><spage>106900</spage><pages>106900-</pages><artnum>106900</artnum><issn>1350-4487</issn><eissn>1879-0925</eissn><abstract>The irradiation fields in boron neutron capture therapy (BNCT) consist of neutrons with a wide energy range and undesired high-intensity γ-rays. As the thermoluminescent dosimeter (TLD) used for BNCT dosimetry is out of production, a new type of γ-ray dosimeter is required for the quality assurance (QA) of the treatment. Therefore, in this study, an optically stimulated luminescent dosimeter (OSLD) made of BeO ceramic was selected and its use in the field of BNCT was investigated. The performance of the dosimeter was tested and the effect of a thermal neutron on the γ-ray dose obtained by the OSLD was measured. The OSLDs had a good γ-ray dose linearity of approximately 300 mGy corresponding to the dose in the quality assurance procedure of BNCT, and the thermal neutron sensitivity of the OSLD was less than that of TLD. •This study aims at analyzing the characteristics of OSLD of beryllium oxide in BNCT irradiation field.•The performance of the dosimeters was tested and the influence of thermal neutron on the γ-ray dose was measured.•The OSLD signal was confirmed to have a lower thermal neutron sensitivity than TLD that have been used for BNCT.•It was confirmed that the OSLD can be used in BNCT irradiation field.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.radmeas.2023.106900</doi><orcidid>https://orcid.org/0000-0002-6195-3177</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1350-4487
ispartof Radiation measurements, 2023-02, Vol.161, p.106900, Article 106900
issn 1350-4487
1879-0925
language eng
recordid cdi_crossref_primary_10_1016_j_radmeas_2023_106900
source ScienceDirect Freedom Collection
subjects Beryllium oxide
BNCT
Boron neutron capture therapy
Optically stimulated luminescent dosimeter
OSLD
title Characteristics of optically stimulated luminescent dosimeter of beryllium oxide in BNCT irradiation field
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T23%3A45%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Characteristics%20of%20optically%20stimulated%20luminescent%20dosimeter%20of%20beryllium%20oxide%20in%20BNCT%20irradiation%20field&rft.jtitle=Radiation%20measurements&rft.au=Matsubayashi,%20Nishiki&rft.date=2023-02&rft.volume=161&rft.spage=106900&rft.pages=106900-&rft.artnum=106900&rft.issn=1350-4487&rft.eissn=1879-0925&rft_id=info:doi/10.1016/j.radmeas.2023.106900&rft_dat=%3Celsevier_cross%3ES135044872300001X%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c309t-b53f2cc59cdaf236b63ca333951662c28d6fe92133d059b9aa99f5bfbaa95b643%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true