Loading…

Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study

Although the risk of radiographic imaging is negligible compared to its benefits, the overall risk to the population is significant due to a large number of these examinations. Therefore, this study was designed to estimate entrance surface air kerma (ESAK) and provide diagnostic reference level (DR...

Full description

Saved in:
Bibliographic Details
Published in:Radiation physics and chemistry (Oxford, England : 1993) England : 1993), 2023-01, Vol.202, p.110593, Article 110593
Main Authors: Masjedi, Hamidreza, Dalvand, Saman, Zamani, Hamed, Zare, Mohammad Hossein, Zarei, Mansoreh
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c265t-b67693b68a1eb12bc267b999cbbac812dad78dcfb08eb85884e4436ae83eeb4d3
container_end_page
container_issue
container_start_page 110593
container_title Radiation physics and chemistry (Oxford, England : 1993)
container_volume 202
creator Masjedi, Hamidreza
Dalvand, Saman
Zamani, Hamed
Zare, Mohammad Hossein
Zarei, Mansoreh
description Although the risk of radiographic imaging is negligible compared to its benefits, the overall risk to the population is significant due to a large number of these examinations. Therefore, this study was designed to estimate entrance surface air kerma (ESAK) and provide diagnostic reference level (DRL) in routine radiological examinations. In this study 783 patients were involved who had a mean age of 41 ± 14 years. The study included five routine radiological examinations; lumbar vertebrae, pelvis, abdomen, chest, and skull from 11 radiology devices located in Yazd province. The ESAK was estimated for each examination, and then the DRL values as the third quartile of the distribution of the ESAK median values were calculated. The effective dose and risk of exposure-induced death (REID) were also estimated using PCXMC (a personal computer-based Monte Carlo) software. The DRL values for the investigated examinations were obtained as: abdomen (anterior-posterior [AP]): 3.57, chest (AP): 1.23, chest (lateral [LAT]): 1.12, chest (posterior-anterior [PA]): 0.48, lumbar vertebrae (AP): 4.16, lumbar vertebrae (LAT): 8.81, lumbar vertebrae (oblique [OB]): 10.33, pelvis (AP): 2.77, pelvis (LAT): 2.82, skull (AP): 2.34, skull (LAT): 1.39, and skull (PA): 2.03 mGy. The lumbar vertebrae (OB) radiology examination had the highest effective dose (1.03 ± 0.76 mSv). In addition, the highest REID value in lumbar examination was associated to stomach cancer (7.03 ± 6.11 deaths per million). Based on the results, although the DRL values were not higher than those of the international organizations' levels, they can be reduced by adequate training of radiographers. •The ESAK in five routine radiological examinations were estimated.•The DRL values as the third quartile of the ESAK median values were calculated.•The effective dose and REID were calculated using PCXMC software.•The DRLs were not higher than those of the international organizations' levels.
doi_str_mv 10.1016/j.radphyschem.2022.110593
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_radphyschem_2022_110593</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969806X22006557</els_id><sourcerecordid>S0969806X22006557</sourcerecordid><originalsourceid>FETCH-LOGICAL-c265t-b67693b68a1eb12bc267b999cbbac812dad78dcfb08eb85884e4436ae83eeb4d3</originalsourceid><addsrcrecordid>eNqNUMtKAzEUDaJgrf5D_ICpyTwyibtS6gMENwruQh532tSZTElmit365WaoC5euDlzueSJ0S8mCEsrudoug7H57jGYL3SIneb6glFSiOEMzymuRES6qczQjgomME_Zxia5i3BFCal4VM_S9joPr1OD8Bg9bwOCHoLwBHMfQqITKBfwJoVNYeYutUxvfJ4rBARoIML22cIAWO49DPyYhwCmS6zdBpVwYvlTnfDLofbzHS9yN7eAyk3wg4DiM9niNLhrVRrj5xTl6f1i_rZ6yl9fH59XyJTM5q4ZMs5qJQjOuKGia63SttRDCaK0Mp7lVtubWNJpw0LzivISyLJgCXgDo0hZzJE66JvQxpvhyH1L1cJSUyGlMuZN_xpTTmPI0ZuKuTlxIAQ8OgozGTeWtC2AGaXv3D5UfcaGIig</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study</title><source>ScienceDirect Journals</source><creator>Masjedi, Hamidreza ; Dalvand, Saman ; Zamani, Hamed ; Zare, Mohammad Hossein ; Zarei, Mansoreh</creator><creatorcontrib>Masjedi, Hamidreza ; Dalvand, Saman ; Zamani, Hamed ; Zare, Mohammad Hossein ; Zarei, Mansoreh</creatorcontrib><description>Although the risk of radiographic imaging is negligible compared to its benefits, the overall risk to the population is significant due to a large number of these examinations. Therefore, this study was designed to estimate entrance surface air kerma (ESAK) and provide diagnostic reference level (DRL) in routine radiological examinations. In this study 783 patients were involved who had a mean age of 41 ± 14 years. The study included five routine radiological examinations; lumbar vertebrae, pelvis, abdomen, chest, and skull from 11 radiology devices located in Yazd province. The ESAK was estimated for each examination, and then the DRL values as the third quartile of the distribution of the ESAK median values were calculated. The effective dose and risk of exposure-induced death (REID) were also estimated using PCXMC (a personal computer-based Monte Carlo) software. The DRL values for the investigated examinations were obtained as: abdomen (anterior-posterior [AP]): 3.57, chest (AP): 1.23, chest (lateral [LAT]): 1.12, chest (posterior-anterior [PA]): 0.48, lumbar vertebrae (AP): 4.16, lumbar vertebrae (LAT): 8.81, lumbar vertebrae (oblique [OB]): 10.33, pelvis (AP): 2.77, pelvis (LAT): 2.82, skull (AP): 2.34, skull (LAT): 1.39, and skull (PA): 2.03 mGy. The lumbar vertebrae (OB) radiology examination had the highest effective dose (1.03 ± 0.76 mSv). In addition, the highest REID value in lumbar examination was associated to stomach cancer (7.03 ± 6.11 deaths per million). Based on the results, although the DRL values were not higher than those of the international organizations' levels, they can be reduced by adequate training of radiographers. •The ESAK in five routine radiological examinations were estimated.•The DRL values as the third quartile of the ESAK median values were calculated.•The effective dose and REID were calculated using PCXMC software.•The DRLs were not higher than those of the international organizations' levels.</description><identifier>ISSN: 0969-806X</identifier><identifier>EISSN: 1879-0895</identifier><identifier>DOI: 10.1016/j.radphyschem.2022.110593</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Cancer risk ; Diagnostic reference level ; Effective dose ; Exposure-induced death ; Radiology</subject><ispartof>Radiation physics and chemistry (Oxford, England : 1993), 2023-01, Vol.202, p.110593, Article 110593</ispartof><rights>2022 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c265t-b67693b68a1eb12bc267b999cbbac812dad78dcfb08eb85884e4436ae83eeb4d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Masjedi, Hamidreza</creatorcontrib><creatorcontrib>Dalvand, Saman</creatorcontrib><creatorcontrib>Zamani, Hamed</creatorcontrib><creatorcontrib>Zare, Mohammad Hossein</creatorcontrib><creatorcontrib>Zarei, Mansoreh</creatorcontrib><title>Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study</title><title>Radiation physics and chemistry (Oxford, England : 1993)</title><description>Although the risk of radiographic imaging is negligible compared to its benefits, the overall risk to the population is significant due to a large number of these examinations. Therefore, this study was designed to estimate entrance surface air kerma (ESAK) and provide diagnostic reference level (DRL) in routine radiological examinations. In this study 783 patients were involved who had a mean age of 41 ± 14 years. The study included five routine radiological examinations; lumbar vertebrae, pelvis, abdomen, chest, and skull from 11 radiology devices located in Yazd province. The ESAK was estimated for each examination, and then the DRL values as the third quartile of the distribution of the ESAK median values were calculated. The effective dose and risk of exposure-induced death (REID) were also estimated using PCXMC (a personal computer-based Monte Carlo) software. The DRL values for the investigated examinations were obtained as: abdomen (anterior-posterior [AP]): 3.57, chest (AP): 1.23, chest (lateral [LAT]): 1.12, chest (posterior-anterior [PA]): 0.48, lumbar vertebrae (AP): 4.16, lumbar vertebrae (LAT): 8.81, lumbar vertebrae (oblique [OB]): 10.33, pelvis (AP): 2.77, pelvis (LAT): 2.82, skull (AP): 2.34, skull (LAT): 1.39, and skull (PA): 2.03 mGy. The lumbar vertebrae (OB) radiology examination had the highest effective dose (1.03 ± 0.76 mSv). In addition, the highest REID value in lumbar examination was associated to stomach cancer (7.03 ± 6.11 deaths per million). Based on the results, although the DRL values were not higher than those of the international organizations' levels, they can be reduced by adequate training of radiographers. •The ESAK in five routine radiological examinations were estimated.•The DRL values as the third quartile of the ESAK median values were calculated.•The effective dose and REID were calculated using PCXMC software.•The DRLs were not higher than those of the international organizations' levels.</description><subject>Cancer risk</subject><subject>Diagnostic reference level</subject><subject>Effective dose</subject><subject>Exposure-induced death</subject><subject>Radiology</subject><issn>0969-806X</issn><issn>1879-0895</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNqNUMtKAzEUDaJgrf5D_ICpyTwyibtS6gMENwruQh532tSZTElmit365WaoC5euDlzueSJ0S8mCEsrudoug7H57jGYL3SIneb6glFSiOEMzymuRES6qczQjgomME_Zxia5i3BFCal4VM_S9joPr1OD8Bg9bwOCHoLwBHMfQqITKBfwJoVNYeYutUxvfJ4rBARoIML22cIAWO49DPyYhwCmS6zdBpVwYvlTnfDLofbzHS9yN7eAyk3wg4DiM9niNLhrVRrj5xTl6f1i_rZ6yl9fH59XyJTM5q4ZMs5qJQjOuKGia63SttRDCaK0Mp7lVtubWNJpw0LzivISyLJgCXgDo0hZzJE66JvQxpvhyH1L1cJSUyGlMuZN_xpTTmPI0ZuKuTlxIAQ8OgozGTeWtC2AGaXv3D5UfcaGIig</recordid><startdate>202301</startdate><enddate>202301</enddate><creator>Masjedi, Hamidreza</creator><creator>Dalvand, Saman</creator><creator>Zamani, Hamed</creator><creator>Zare, Mohammad Hossein</creator><creator>Zarei, Mansoreh</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202301</creationdate><title>Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study</title><author>Masjedi, Hamidreza ; Dalvand, Saman ; Zamani, Hamed ; Zare, Mohammad Hossein ; Zarei, Mansoreh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c265t-b67693b68a1eb12bc267b999cbbac812dad78dcfb08eb85884e4436ae83eeb4d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Cancer risk</topic><topic>Diagnostic reference level</topic><topic>Effective dose</topic><topic>Exposure-induced death</topic><topic>Radiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Masjedi, Hamidreza</creatorcontrib><creatorcontrib>Dalvand, Saman</creatorcontrib><creatorcontrib>Zamani, Hamed</creatorcontrib><creatorcontrib>Zare, Mohammad Hossein</creatorcontrib><creatorcontrib>Zarei, Mansoreh</creatorcontrib><collection>CrossRef</collection><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Masjedi, Hamidreza</au><au>Dalvand, Saman</au><au>Zamani, Hamed</au><au>Zare, Mohammad Hossein</au><au>Zarei, Mansoreh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study</atitle><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle><date>2023-01</date><risdate>2023</risdate><volume>202</volume><spage>110593</spage><pages>110593-</pages><artnum>110593</artnum><issn>0969-806X</issn><eissn>1879-0895</eissn><abstract>Although the risk of radiographic imaging is negligible compared to its benefits, the overall risk to the population is significant due to a large number of these examinations. Therefore, this study was designed to estimate entrance surface air kerma (ESAK) and provide diagnostic reference level (DRL) in routine radiological examinations. In this study 783 patients were involved who had a mean age of 41 ± 14 years. The study included five routine radiological examinations; lumbar vertebrae, pelvis, abdomen, chest, and skull from 11 radiology devices located in Yazd province. The ESAK was estimated for each examination, and then the DRL values as the third quartile of the distribution of the ESAK median values were calculated. The effective dose and risk of exposure-induced death (REID) were also estimated using PCXMC (a personal computer-based Monte Carlo) software. The DRL values for the investigated examinations were obtained as: abdomen (anterior-posterior [AP]): 3.57, chest (AP): 1.23, chest (lateral [LAT]): 1.12, chest (posterior-anterior [PA]): 0.48, lumbar vertebrae (AP): 4.16, lumbar vertebrae (LAT): 8.81, lumbar vertebrae (oblique [OB]): 10.33, pelvis (AP): 2.77, pelvis (LAT): 2.82, skull (AP): 2.34, skull (LAT): 1.39, and skull (PA): 2.03 mGy. The lumbar vertebrae (OB) radiology examination had the highest effective dose (1.03 ± 0.76 mSv). In addition, the highest REID value in lumbar examination was associated to stomach cancer (7.03 ± 6.11 deaths per million). Based on the results, although the DRL values were not higher than those of the international organizations' levels, they can be reduced by adequate training of radiographers. •The ESAK in five routine radiological examinations were estimated.•The DRL values as the third quartile of the ESAK median values were calculated.•The effective dose and REID were calculated using PCXMC software.•The DRLs were not higher than those of the international organizations' levels.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.radphyschem.2022.110593</doi></addata></record>
fulltext fulltext
identifier ISSN: 0969-806X
ispartof Radiation physics and chemistry (Oxford, England : 1993), 2023-01, Vol.202, p.110593, Article 110593
issn 0969-806X
1879-0895
language eng
recordid cdi_crossref_primary_10_1016_j_radphyschem_2022_110593
source ScienceDirect Journals
subjects Cancer risk
Diagnostic reference level
Effective dose
Exposure-induced death
Radiology
title Estimating the entrance surface air kerma and diagnostic reference level in routine radiography examinations: A multi-center study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T21%3A40%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimating%20the%20entrance%20surface%20air%20kerma%20and%20diagnostic%20reference%20level%20in%20routine%20radiography%20examinations:%20A%20multi-center%20study&rft.jtitle=Radiation%20physics%20and%20chemistry%20(Oxford,%20England%20:%201993)&rft.au=Masjedi,%20Hamidreza&rft.date=2023-01&rft.volume=202&rft.spage=110593&rft.pages=110593-&rft.artnum=110593&rft.issn=0969-806X&rft.eissn=1879-0895&rft_id=info:doi/10.1016/j.radphyschem.2022.110593&rft_dat=%3Celsevier_cross%3ES0969806X22006557%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c265t-b67693b68a1eb12bc267b999cbbac812dad78dcfb08eb85884e4436ae83eeb4d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true