Loading…

The effect of tissue-segmented attenuation maps on PET quantification with a special focus on large arteries

Accuracy on quantitative PET image analysis relies on the correct application of attenuation correction which is one of the major challenges for PET/MRI that remains to be solved. The purpose of this study is to evaluate the effect of MRI-based attenuation maps and the use of flexible coils on the q...

Full description

Saved in:
Bibliographic Details
Published in:Revista Española de medicina nuclear e imagen molecular (English ed.) 2018-03, Vol.37 (2), p.94-102
Main Authors: Mota-Cobian, A., Alonso-Farto, J.C., Fernández-Friera, L., Sánchez-González, J., López-Melgar, B., Jiménez-Borreguero, L.J., Fuster, V., Ruiz-Cabello, J., España, S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Accuracy on quantitative PET image analysis relies on the correct application of attenuation correction which is one of the major challenges for PET/MRI that remains to be solved. The purpose of this study is to evaluate the effect of MRI-based attenuation maps and the use of flexible coils on the quantitative accuracy of PET images with a special focus on large arteries. PET/CT data from eight oncologic patients was used. PET data was reconstructed using attenuation maps with different level of detail emulating several approaches available on current PET/MRI scanners. PET images obtained with CT-based and MRI-based attenuation maps were compared to evaluate the quantitative biases obtained. The quantitative effect produced by flexible MRI receiver coils on the attenuation maps was also studied. The use of simpler attenuation maps produced increased biases between PET data reconstructed with CT-based and MRI-based attenuation maps for fat, non-fat soft-tissues and bone. Biases in lung were very high due to the large heterogeneity and inter-patient variability of the lung. The quantification on large arteries had small deviations except for the case when flexible coils were used. The TBRprovided smaller biases in all cases as it cancelled out the similar deviations obtained for arteries and reference veins. Simplified attenuation maps used on PET/MRI significantly increase the quantitative variability of PET images especially on lungs and bones. The quantification of PET images acquired with PET/MRI scanners applied to studies of atherosclerosis has small deviations, especially when the TBR is considered. La precisión cuantitativa en PET requiere una adecuada aplicación de la corrección de atenuación, lo cual representa uno de los mayores retos que aún están por resolver en la técnica PET/RM. El propósito de este estudio es evaluar el efecto de utilizar mapas de atenuación basados en RM y el uso de antenas flexibles sobre la precisión cuantitativa en PET con especial hincapié en grandes arterias. Se utilizaron datos PET/TC de 8 pacientes oncológicos. Los datos PET fueron reconstruidos utilizando mapas de atenuación con diferente nivel de detalle emulando las distintas aproximaciones utilizadas actualmente por lo equipos PET/RM. Las imágenes PET obtenidas con mapas de atenuación basados en TC y RM fueron comparadas para evaluar las desviaciones cuantitativas obtenidas. El efecto producido por las antenas flexibles fue también estudiado. El uso de mapas de at
ISSN:2253-8089
2253-8089
DOI:10.1016/j.remnie.2017.11.011