Loading…
Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism
Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an e...
Saved in:
Published in: | Renewable energy 2024-02, Vol.221, p.119741, Article 119741 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553 |
---|---|
cites | cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553 |
container_end_page | |
container_issue | |
container_start_page | 119741 |
container_title | Renewable energy |
container_volume | 221 |
creator | Tao, Cheng Tao, Tao He, Shukai Bai, Xinjian Liu, Yongqian |
description | Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis.
•A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis. |
doi_str_mv | 10.1016/j.renene.2023.119741 |
format | article |
fullrecord | <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_renene_2023_119741</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0960148123016567</els_id><sourcerecordid>S0960148123016567</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</originalsourceid><addsrcrecordid>eNp9kNFKwzAUhoMoOKdv4EVeIDUnTZv2RnBjTmEymBteSUiT0y1jbaXpFN_elu1azsXPufh-fj5C7oFHwCF92Ect1v1Fgos4AsiVhAsygkzljKeZuCQjnqecgczgmtyEsOcckkzJEfn88LWj3bEtfI20OBiH1Ftfb6nzZls3wQd6DMM_Ye9vy_WMTTybrzbU9NjqeUZtUw2ooz--253RCu3O1D5Ut-SqNIeAd-cck83zbD19YYvl_HX6tGA25mnHcudEgShEXKJxhTBgIIuTNMudEZgWKnelQp6lFhJplJRCKmV4WYAqAJMkHhN56rVtE0KLpf5qfWXaXw1cD4r0Xp8U6UGRPinqsccThv22b4-tDtZjbdH5Fm2nXeP_L_gD17Zw0g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><source>ScienceDirect Freedom Collection</source><creator>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</creator><creatorcontrib>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</creatorcontrib><description>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis.
•A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</description><identifier>ISSN: 0960-1481</identifier><identifier>EISSN: 1879-0682</identifier><identifier>DOI: 10.1016/j.renene.2023.119741</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>B-SMOTE ; Bi-GRU ; Hybrid features ; Icing diagnosis ; SCADA ; Wind turbine blade</subject><ispartof>Renewable energy, 2024-02, Vol.221, p.119741, Article 119741</ispartof><rights>2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</citedby><cites>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</cites><orcidid>0000-0002-6874-4351</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Tao, Cheng</creatorcontrib><creatorcontrib>Tao, Tao</creatorcontrib><creatorcontrib>He, Shukai</creatorcontrib><creatorcontrib>Bai, Xinjian</creatorcontrib><creatorcontrib>Liu, Yongqian</creatorcontrib><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><title>Renewable energy</title><description>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis.
•A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</description><subject>B-SMOTE</subject><subject>Bi-GRU</subject><subject>Hybrid features</subject><subject>Icing diagnosis</subject><subject>SCADA</subject><subject>Wind turbine blade</subject><issn>0960-1481</issn><issn>1879-0682</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kNFKwzAUhoMoOKdv4EVeIDUnTZv2RnBjTmEymBteSUiT0y1jbaXpFN_elu1azsXPufh-fj5C7oFHwCF92Ect1v1Fgos4AsiVhAsygkzljKeZuCQjnqecgczgmtyEsOcckkzJEfn88LWj3bEtfI20OBiH1Ftfb6nzZls3wQd6DMM_Ye9vy_WMTTybrzbU9NjqeUZtUw2ooz--253RCu3O1D5Ut-SqNIeAd-cck83zbD19YYvl_HX6tGA25mnHcudEgShEXKJxhTBgIIuTNMudEZgWKnelQp6lFhJplJRCKmV4WYAqAJMkHhN56rVtE0KLpf5qfWXaXw1cD4r0Xp8U6UGRPinqsccThv22b4-tDtZjbdH5Fm2nXeP_L_gD17Zw0g</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Tao, Cheng</creator><creator>Tao, Tao</creator><creator>He, Shukai</creator><creator>Bai, Xinjian</creator><creator>Liu, Yongqian</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-6874-4351</orcidid></search><sort><creationdate>202402</creationdate><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><author>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>B-SMOTE</topic><topic>Bi-GRU</topic><topic>Hybrid features</topic><topic>Icing diagnosis</topic><topic>SCADA</topic><topic>Wind turbine blade</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tao, Cheng</creatorcontrib><creatorcontrib>Tao, Tao</creatorcontrib><creatorcontrib>He, Shukai</creatorcontrib><creatorcontrib>Bai, Xinjian</creatorcontrib><creatorcontrib>Liu, Yongqian</creatorcontrib><collection>CrossRef</collection><jtitle>Renewable energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tao, Cheng</au><au>Tao, Tao</au><au>He, Shukai</au><au>Bai, Xinjian</au><au>Liu, Yongqian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</atitle><jtitle>Renewable energy</jtitle><date>2024-02</date><risdate>2024</risdate><volume>221</volume><spage>119741</spage><pages>119741-</pages><artnum>119741</artnum><issn>0960-1481</issn><eissn>1879-0682</eissn><abstract>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis.
•A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.renene.2023.119741</doi><orcidid>https://orcid.org/0000-0002-6874-4351</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0960-1481 |
ispartof | Renewable energy, 2024-02, Vol.221, p.119741, Article 119741 |
issn | 0960-1481 1879-0682 |
language | eng |
recordid | cdi_crossref_primary_10_1016_j_renene_2023_119741 |
source | ScienceDirect Freedom Collection |
subjects | B-SMOTE Bi-GRU Hybrid features Icing diagnosis SCADA Wind turbine blade |
title | Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T11%3A15%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wind%20turbine%20blade%20icing%20diagnosis%20using%20B-SMOTE-Bi-GRU%20and%20RFE%20combined%20with%20icing%20mechanism&rft.jtitle=Renewable%20energy&rft.au=Tao,%20Cheng&rft.date=2024-02&rft.volume=221&rft.spage=119741&rft.pages=119741-&rft.artnum=119741&rft.issn=0960-1481&rft.eissn=1879-0682&rft_id=info:doi/10.1016/j.renene.2023.119741&rft_dat=%3Celsevier_cross%3ES0960148123016567%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |