Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism

Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an e...

Full description

Saved in:
Bibliographic Details
Published in:Renewable energy 2024-02, Vol.221, p.119741, Article 119741
Main Authors: Tao, Cheng, Tao, Tao, He, Shukai, Bai, Xinjian, Liu, Yongqian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553
cites cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553
container_end_page
container_issue
container_start_page 119741
container_title Renewable energy
container_volume 221
creator Tao, Cheng
Tao, Tao
He, Shukai
Bai, Xinjian
Liu, Yongqian
description Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis. •A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.
doi_str_mv 10.1016/j.renene.2023.119741
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_renene_2023_119741</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0960148123016567</els_id><sourcerecordid>S0960148123016567</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</originalsourceid><addsrcrecordid>eNp9kNFKwzAUhoMoOKdv4EVeIDUnTZv2RnBjTmEymBteSUiT0y1jbaXpFN_elu1azsXPufh-fj5C7oFHwCF92Ect1v1Fgos4AsiVhAsygkzljKeZuCQjnqecgczgmtyEsOcckkzJEfn88LWj3bEtfI20OBiH1Ftfb6nzZls3wQd6DMM_Ye9vy_WMTTybrzbU9NjqeUZtUw2ooz--253RCu3O1D5Ut-SqNIeAd-cck83zbD19YYvl_HX6tGA25mnHcudEgShEXKJxhTBgIIuTNMudEZgWKnelQp6lFhJplJRCKmV4WYAqAJMkHhN56rVtE0KLpf5qfWXaXw1cD4r0Xp8U6UGRPinqsccThv22b4-tDtZjbdH5Fm2nXeP_L_gD17Zw0g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><source>ScienceDirect Freedom Collection</source><creator>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</creator><creatorcontrib>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</creatorcontrib><description>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis. •A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</description><identifier>ISSN: 0960-1481</identifier><identifier>EISSN: 1879-0682</identifier><identifier>DOI: 10.1016/j.renene.2023.119741</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>B-SMOTE ; Bi-GRU ; Hybrid features ; Icing diagnosis ; SCADA ; Wind turbine blade</subject><ispartof>Renewable energy, 2024-02, Vol.221, p.119741, Article 119741</ispartof><rights>2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</citedby><cites>FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</cites><orcidid>0000-0002-6874-4351</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Tao, Cheng</creatorcontrib><creatorcontrib>Tao, Tao</creatorcontrib><creatorcontrib>He, Shukai</creatorcontrib><creatorcontrib>Bai, Xinjian</creatorcontrib><creatorcontrib>Liu, Yongqian</creatorcontrib><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><title>Renewable energy</title><description>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis. •A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</description><subject>B-SMOTE</subject><subject>Bi-GRU</subject><subject>Hybrid features</subject><subject>Icing diagnosis</subject><subject>SCADA</subject><subject>Wind turbine blade</subject><issn>0960-1481</issn><issn>1879-0682</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kNFKwzAUhoMoOKdv4EVeIDUnTZv2RnBjTmEymBteSUiT0y1jbaXpFN_elu1azsXPufh-fj5C7oFHwCF92Ect1v1Fgos4AsiVhAsygkzljKeZuCQjnqecgczgmtyEsOcckkzJEfn88LWj3bEtfI20OBiH1Ftfb6nzZls3wQd6DMM_Ye9vy_WMTTybrzbU9NjqeUZtUw2ooz--253RCu3O1D5Ut-SqNIeAd-cck83zbD19YYvl_HX6tGA25mnHcudEgShEXKJxhTBgIIuTNMudEZgWKnelQp6lFhJplJRCKmV4WYAqAJMkHhN56rVtE0KLpf5qfWXaXw1cD4r0Xp8U6UGRPinqsccThv22b4-tDtZjbdH5Fm2nXeP_L_gD17Zw0g</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Tao, Cheng</creator><creator>Tao, Tao</creator><creator>He, Shukai</creator><creator>Bai, Xinjian</creator><creator>Liu, Yongqian</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-6874-4351</orcidid></search><sort><creationdate>202402</creationdate><title>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</title><author>Tao, Cheng ; Tao, Tao ; He, Shukai ; Bai, Xinjian ; Liu, Yongqian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>B-SMOTE</topic><topic>Bi-GRU</topic><topic>Hybrid features</topic><topic>Icing diagnosis</topic><topic>SCADA</topic><topic>Wind turbine blade</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tao, Cheng</creatorcontrib><creatorcontrib>Tao, Tao</creatorcontrib><creatorcontrib>He, Shukai</creatorcontrib><creatorcontrib>Bai, Xinjian</creatorcontrib><creatorcontrib>Liu, Yongqian</creatorcontrib><collection>CrossRef</collection><jtitle>Renewable energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tao, Cheng</au><au>Tao, Tao</au><au>He, Shukai</au><au>Bai, Xinjian</au><au>Liu, Yongqian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism</atitle><jtitle>Renewable energy</jtitle><date>2024-02</date><risdate>2024</risdate><volume>221</volume><spage>119741</spage><pages>119741-</pages><artnum>119741</artnum><issn>0960-1481</issn><eissn>1879-0682</eissn><abstract>Low temperature and high humidity in winter can easily lead to blade icing, which severely impacts the actual power output and safe operation of wind turbines. However, existing blade icing diagnostic methods suffer from inadequacies in feature extraction and the accuracy. Therefore, we propose an efficient and accurate blade icing diagnosis method. Initially, we develop hybrid features that include both short-time and long-time features. RFE is combined with icing mechanism to extract short-time features, and the sliding window algorithm is used to extract long-time features. Secondly, the B-SMOTE method is used to synthesize minority icing samples. Finally, the B-SMOTE-Bi-GRU model is applied to validate the superiority of the proposed method. Compared to the features extracted based on the icing mechanism and the sliding window algorithm, the average improvements in recall, TNR, and accuracy for each wind turbine is between 0.26% and 4.87 %, 0.23%–4.60 %, and 0.05%–2.73 %, respectively. In comparison to the other models, the B-SMOTE-Bi-GRU method proposed in this paper enhances the recall and TNR of each wind turbine by between 0.06%-13.10 % and 0.07%–12.01 %, respectively. The results indicate that the hybrid features and B-SMOTE-Bi-GRU model proposed in this paper offer a more effective and accurate approach to blade icing diagnosis. •A new feature extraction method is proposed based on RFE combined with icing mechanism.•Icing diagnostic model based on the B-SMOTE-Bi-GRU model is proposed.•The proposed new method of feature extraction enhances the accuracy of blade icing diagnosis.•The B-SMOTE-Bi-GRU model is superior to existing models.•The proposed method achieves higher accuracy for blade icing diagnosis.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.renene.2023.119741</doi><orcidid>https://orcid.org/0000-0002-6874-4351</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0960-1481
ispartof Renewable energy, 2024-02, Vol.221, p.119741, Article 119741
issn 0960-1481
1879-0682
language eng
recordid cdi_crossref_primary_10_1016_j_renene_2023_119741
source ScienceDirect Freedom Collection
subjects B-SMOTE
Bi-GRU
Hybrid features
Icing diagnosis
SCADA
Wind turbine blade
title Wind turbine blade icing diagnosis using B-SMOTE-Bi-GRU and RFE combined with icing mechanism
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T11%3A15%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Wind%20turbine%20blade%20icing%20diagnosis%20using%20B-SMOTE-Bi-GRU%20and%20RFE%20combined%20with%20icing%20mechanism&rft.jtitle=Renewable%20energy&rft.au=Tao,%20Cheng&rft.date=2024-02&rft.volume=221&rft.spage=119741&rft.pages=119741-&rft.artnum=119741&rft.issn=0960-1481&rft.eissn=1879-0682&rft_id=info:doi/10.1016/j.renene.2023.119741&rft_dat=%3Celsevier_cross%3ES0960148123016567%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c306t-9dd2bee223feadb2a1a1835689da2e6b79df7e086c154a7442477a0fb17b1e553%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true