Loading…

Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors

Amines and ammonia can harm the environment, even in small concentrations. Efficient amine sensors are required to monitor the quality of food and air. A growing number of industries need sensors that can recognize a particular gas. Here, we demonstrate composite films made of plasma polymerized vin...

Full description

Saved in:
Bibliographic Details
Published in:Surfaces and interfaces 2023-11, Vol.42, p.103453, Article 103453
Main Authors: Nadekar, Baliram, Khollam, Yogesh B., Shaikh, Shoyebmohamad F., Wavhal, Dattatray, Varshney, Pankaj, Pandit, Bidhan, More, Pravin S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3
cites cdi_FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3
container_end_page
container_issue
container_start_page 103453
container_title Surfaces and interfaces
container_volume 42
creator Nadekar, Baliram
Khollam, Yogesh B.
Shaikh, Shoyebmohamad F.
Wavhal, Dattatray
Varshney, Pankaj
Pandit, Bidhan
More, Pravin S.
description Amines and ammonia can harm the environment, even in small concentrations. Efficient amine sensors are required to monitor the quality of food and air. A growing number of industries need sensors that can recognize a particular gas. Here, we demonstrate composite films made of plasma polymerized vinyl acetate (PVAc) and reduced graphene oxide (rGO) to address the crucial issues of limited selectivity, long-term instability, and temperature instability in chemoresistive gas sensors. Change in resistance of the sensor was studied in presence of analyte gas. An inductively linked plasma polymerization setup prepares PVAc films under carefully calibrated deposition conditions. Several samples are analyzed to determine the ideal PVAc to rGO ratio for the composite film. Compared to individual PVAc and rGO films, final samples have demonstrated a sensitivity to ammonia and amines up to 15 times higher. The sensitivity of measuring ammonia/amines ranges from 628 for trimethylamine to a maximum of 3389 for methylamine. The sensitivity of measuring ammonia is 1621, while the sensitivity of measuring dimethylamine is 2041. The redox reaction, charge transfer, and swelling of polymer films explain potential sensing processes. Ammonia/amine selectivity has been enhanced by up to 160 compared to other volatile organic compounds (VOCs) using PVAc-rGO composite films. Based on unique selectivity, these films may also successfully distinguish between ammonia and other amines. It is shown that fluctuations in temperature between 30°C and 150°C did not affect the sensitivity of PVAc-rGO films. These films remain sensitive for far longer than three months. As a result, composite films of PVAc-rGO may be used to fabricate exceptionally sensitive and reliable gas sensors for ammonia/amines environmental monitoring. [Display omitted]
doi_str_mv 10.1016/j.surfin.2023.103453
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_surfin_2023_103453</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2468023023008234</els_id><sourcerecordid>S2468023023008234</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRS0EEhX0D1j4B9L6kecGCVXlIVViA2vLdSatq9iObKcifAWfTEJYsGI1V6O5944OQneUrCih-fq0Cr1vtF0xwvi44mnGL9CCpXmZjBty-Udfo2UIJ0IILYsqo9kCfW3tUVoFNZbGOKvlWhptIeAANuiozzoOWEbsnTM4gunAy9h7wH3Q9oC7VgYjcefawYDXn2POpM_aDi2WCqKMkHio-6nh4GV3BAvYfegasHKmc2MH4Ea35qfQ-XCLrhrZBlj-zhv0_rh92zwnu9enl83DLlGc5DEpCprvVVOlimZFyui-YUWZV2UtCVeMV1XBIS8LyZq8rsrxmKWsbKTKKS05JYrfoHTOVd6F4KERnddG-kFQIiaw4iRmsGICK2awo-1-tsH421mDF0FpmABqDyqK2un_A74B1F2HMg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Nadekar, Baliram ; Khollam, Yogesh B. ; Shaikh, Shoyebmohamad F. ; Wavhal, Dattatray ; Varshney, Pankaj ; Pandit, Bidhan ; More, Pravin S.</creator><creatorcontrib>Nadekar, Baliram ; Khollam, Yogesh B. ; Shaikh, Shoyebmohamad F. ; Wavhal, Dattatray ; Varshney, Pankaj ; Pandit, Bidhan ; More, Pravin S.</creatorcontrib><description>Amines and ammonia can harm the environment, even in small concentrations. Efficient amine sensors are required to monitor the quality of food and air. A growing number of industries need sensors that can recognize a particular gas. Here, we demonstrate composite films made of plasma polymerized vinyl acetate (PVAc) and reduced graphene oxide (rGO) to address the crucial issues of limited selectivity, long-term instability, and temperature instability in chemoresistive gas sensors. Change in resistance of the sensor was studied in presence of analyte gas. An inductively linked plasma polymerization setup prepares PVAc films under carefully calibrated deposition conditions. Several samples are analyzed to determine the ideal PVAc to rGO ratio for the composite film. Compared to individual PVAc and rGO films, final samples have demonstrated a sensitivity to ammonia and amines up to 15 times higher. The sensitivity of measuring ammonia/amines ranges from 628 for trimethylamine to a maximum of 3389 for methylamine. The sensitivity of measuring ammonia is 1621, while the sensitivity of measuring dimethylamine is 2041. The redox reaction, charge transfer, and swelling of polymer films explain potential sensing processes. Ammonia/amine selectivity has been enhanced by up to 160 compared to other volatile organic compounds (VOCs) using PVAc-rGO composite films. Based on unique selectivity, these films may also successfully distinguish between ammonia and other amines. It is shown that fluctuations in temperature between 30°C and 150°C did not affect the sensitivity of PVAc-rGO films. These films remain sensitive for far longer than three months. As a result, composite films of PVAc-rGO may be used to fabricate exceptionally sensitive and reliable gas sensors for ammonia/amines environmental monitoring. [Display omitted]</description><identifier>ISSN: 2468-0230</identifier><identifier>EISSN: 2468-0230</identifier><identifier>DOI: 10.1016/j.surfin.2023.103453</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>composite ; polymerized vinyl acetate ; reduced graphene oxide ; sensors</subject><ispartof>Surfaces and interfaces, 2023-11, Vol.42, p.103453, Article 103453</ispartof><rights>2023</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3</citedby><cites>FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3</cites><orcidid>0000-0003-4656-9289</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Nadekar, Baliram</creatorcontrib><creatorcontrib>Khollam, Yogesh B.</creatorcontrib><creatorcontrib>Shaikh, Shoyebmohamad F.</creatorcontrib><creatorcontrib>Wavhal, Dattatray</creatorcontrib><creatorcontrib>Varshney, Pankaj</creatorcontrib><creatorcontrib>Pandit, Bidhan</creatorcontrib><creatorcontrib>More, Pravin S.</creatorcontrib><title>Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors</title><title>Surfaces and interfaces</title><description>Amines and ammonia can harm the environment, even in small concentrations. Efficient amine sensors are required to monitor the quality of food and air. A growing number of industries need sensors that can recognize a particular gas. Here, we demonstrate composite films made of plasma polymerized vinyl acetate (PVAc) and reduced graphene oxide (rGO) to address the crucial issues of limited selectivity, long-term instability, and temperature instability in chemoresistive gas sensors. Change in resistance of the sensor was studied in presence of analyte gas. An inductively linked plasma polymerization setup prepares PVAc films under carefully calibrated deposition conditions. Several samples are analyzed to determine the ideal PVAc to rGO ratio for the composite film. Compared to individual PVAc and rGO films, final samples have demonstrated a sensitivity to ammonia and amines up to 15 times higher. The sensitivity of measuring ammonia/amines ranges from 628 for trimethylamine to a maximum of 3389 for methylamine. The sensitivity of measuring ammonia is 1621, while the sensitivity of measuring dimethylamine is 2041. The redox reaction, charge transfer, and swelling of polymer films explain potential sensing processes. Ammonia/amine selectivity has been enhanced by up to 160 compared to other volatile organic compounds (VOCs) using PVAc-rGO composite films. Based on unique selectivity, these films may also successfully distinguish between ammonia and other amines. It is shown that fluctuations in temperature between 30°C and 150°C did not affect the sensitivity of PVAc-rGO films. These films remain sensitive for far longer than three months. As a result, composite films of PVAc-rGO may be used to fabricate exceptionally sensitive and reliable gas sensors for ammonia/amines environmental monitoring. [Display omitted]</description><subject>composite</subject><subject>polymerized vinyl acetate</subject><subject>reduced graphene oxide</subject><subject>sensors</subject><issn>2468-0230</issn><issn>2468-0230</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOwzAQRS0EEhX0D1j4B9L6kecGCVXlIVViA2vLdSatq9iObKcifAWfTEJYsGI1V6O5944OQneUrCih-fq0Cr1vtF0xwvi44mnGL9CCpXmZjBty-Udfo2UIJ0IILYsqo9kCfW3tUVoFNZbGOKvlWhptIeAANuiozzoOWEbsnTM4gunAy9h7wH3Q9oC7VgYjcefawYDXn2POpM_aDi2WCqKMkHio-6nh4GV3BAvYfegasHKmc2MH4Ea35qfQ-XCLrhrZBlj-zhv0_rh92zwnu9enl83DLlGc5DEpCprvVVOlimZFyui-YUWZV2UtCVeMV1XBIS8LyZq8rsrxmKWsbKTKKS05JYrfoHTOVd6F4KERnddG-kFQIiaw4iRmsGICK2awo-1-tsH421mDF0FpmABqDyqK2un_A74B1F2HMg</recordid><startdate>202311</startdate><enddate>202311</enddate><creator>Nadekar, Baliram</creator><creator>Khollam, Yogesh B.</creator><creator>Shaikh, Shoyebmohamad F.</creator><creator>Wavhal, Dattatray</creator><creator>Varshney, Pankaj</creator><creator>Pandit, Bidhan</creator><creator>More, Pravin S.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-4656-9289</orcidid></search><sort><creationdate>202311</creationdate><title>Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors</title><author>Nadekar, Baliram ; Khollam, Yogesh B. ; Shaikh, Shoyebmohamad F. ; Wavhal, Dattatray ; Varshney, Pankaj ; Pandit, Bidhan ; More, Pravin S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>composite</topic><topic>polymerized vinyl acetate</topic><topic>reduced graphene oxide</topic><topic>sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nadekar, Baliram</creatorcontrib><creatorcontrib>Khollam, Yogesh B.</creatorcontrib><creatorcontrib>Shaikh, Shoyebmohamad F.</creatorcontrib><creatorcontrib>Wavhal, Dattatray</creatorcontrib><creatorcontrib>Varshney, Pankaj</creatorcontrib><creatorcontrib>Pandit, Bidhan</creatorcontrib><creatorcontrib>More, Pravin S.</creatorcontrib><collection>CrossRef</collection><jtitle>Surfaces and interfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nadekar, Baliram</au><au>Khollam, Yogesh B.</au><au>Shaikh, Shoyebmohamad F.</au><au>Wavhal, Dattatray</au><au>Varshney, Pankaj</au><au>Pandit, Bidhan</au><au>More, Pravin S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors</atitle><jtitle>Surfaces and interfaces</jtitle><date>2023-11</date><risdate>2023</risdate><volume>42</volume><spage>103453</spage><pages>103453-</pages><artnum>103453</artnum><issn>2468-0230</issn><eissn>2468-0230</eissn><abstract>Amines and ammonia can harm the environment, even in small concentrations. Efficient amine sensors are required to monitor the quality of food and air. A growing number of industries need sensors that can recognize a particular gas. Here, we demonstrate composite films made of plasma polymerized vinyl acetate (PVAc) and reduced graphene oxide (rGO) to address the crucial issues of limited selectivity, long-term instability, and temperature instability in chemoresistive gas sensors. Change in resistance of the sensor was studied in presence of analyte gas. An inductively linked plasma polymerization setup prepares PVAc films under carefully calibrated deposition conditions. Several samples are analyzed to determine the ideal PVAc to rGO ratio for the composite film. Compared to individual PVAc and rGO films, final samples have demonstrated a sensitivity to ammonia and amines up to 15 times higher. The sensitivity of measuring ammonia/amines ranges from 628 for trimethylamine to a maximum of 3389 for methylamine. The sensitivity of measuring ammonia is 1621, while the sensitivity of measuring dimethylamine is 2041. The redox reaction, charge transfer, and swelling of polymer films explain potential sensing processes. Ammonia/amine selectivity has been enhanced by up to 160 compared to other volatile organic compounds (VOCs) using PVAc-rGO composite films. Based on unique selectivity, these films may also successfully distinguish between ammonia and other amines. It is shown that fluctuations in temperature between 30°C and 150°C did not affect the sensitivity of PVAc-rGO films. These films remain sensitive for far longer than three months. As a result, composite films of PVAc-rGO may be used to fabricate exceptionally sensitive and reliable gas sensors for ammonia/amines environmental monitoring. [Display omitted]</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.surfin.2023.103453</doi><orcidid>https://orcid.org/0000-0003-4656-9289</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2468-0230
ispartof Surfaces and interfaces, 2023-11, Vol.42, p.103453, Article 103453
issn 2468-0230
2468-0230
language eng
recordid cdi_crossref_primary_10_1016_j_surfin_2023_103453
source ScienceDirect Freedom Collection 2022-2024
subjects composite
polymerized vinyl acetate
reduced graphene oxide
sensors
title Enhanced ammonia/amines sensitivity at room temperature using plasma polymerized polyvinyl acetate-reduced graphene oxide composite film sensors
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T22%3A14%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhanced%20ammonia/amines%20sensitivity%20at%20room%20temperature%20using%20plasma%20polymerized%20polyvinyl%20acetate-reduced%20graphene%20oxide%20composite%20film%20sensors&rft.jtitle=Surfaces%20and%20interfaces&rft.au=Nadekar,%20Baliram&rft.date=2023-11&rft.volume=42&rft.spage=103453&rft.pages=103453-&rft.artnum=103453&rft.issn=2468-0230&rft.eissn=2468-0230&rft_id=info:doi/10.1016/j.surfin.2023.103453&rft_dat=%3Celsevier_cross%3ES2468023023008234%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c306t-7716bcf94c157421bf278698da03c239973e687a2f6d987162428fac6118310c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true