Comparative study of the clinical performance of two supraglottic airway devices, Laryngeal Mask Airway Supreme and BASKA Balum Mask in adult patients for general anaesthesia

The oropharyngeal leak pressure (OLP) of supraglottic airway devices (SGADs) is an important determinant of their efficacy to provide positive pressure ventilation, whereas the provision to prevent aspiration determines its safety. This study aims to compare the clinical performance of Laryngeal Mas...

Full description

Saved in:
Bibliographic Details
Published in:Trends in anaesthesia & critical care 2023-12, Vol.53, p.101308, Article 101308
Main Authors: Singh, Pradeep, Bhatia, P.S., Gupta, Arushi, Mehta, Khushboo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The oropharyngeal leak pressure (OLP) of supraglottic airway devices (SGADs) is an important determinant of their efficacy to provide positive pressure ventilation, whereas the provision to prevent aspiration determines its safety. This study aims to compare the clinical performance of Laryngeal Mask Airway (LMA) Supreme versus BASKA Balum Mask. Seventy adult patients (18–65 years) posted for elective surgeries general anaesthesia were prospectively randomised into group B (BASKA Mask) and Group S (LMA Supreme). The primary outcome was to measure the OLP at 5 and 30 min after device insertion and secondarily, to compare the ease and time of insertion, number of attempts, leak fraction, anatomical position of the devices, and adverse respiratory event if any. The OLP of BASKA Mask was significantly higher than LMA Supreme (31.37 ± 1.73 cmH2O versus 23.6 ± 1.73 cmH2O at 5 min and 35.94 ± 3.84 cmH2O versus 23.71 ± 1.69 cmH2O at 30 min). The time taken to insert BASKA Mask was also less (11.49 ± 2.38 s) than LMA Supreme (14.66 ± 2.79 s). Peak airway pressures were also notably less in group B than group S at both 5 and 30 min after device placement (13.43 ± 1.44 vs 18.66 ± 1.43 cmH2O and 14.91 ± 1.46 vs 21.37 ± 1.88 cmH2O). The leak fraction ranged between 1.5 and 4.3% in both groups. All other parameters studied were also comparable. BASKA Mask had a higher OLP, lower peak pressure, shorter time to insertion than LMA Supreme. The leak fraction, ease of insertion, number of attempts, and anatomical position of the devices were comparable in both groups. •BASKA Mask is superior to LMA Supreme with respect to higher OLP and faster placement.•The peak airway pressures are significantly lower with BASKA mask.•The reusable BASKA Balum variant may be more cost effective than LMA Supreme.
ISSN:2210-8440
DOI:10.1016/j.tacc.2023.101308