Loading…
Comparison of high specificity with standard versions of a quantitative latex D-dimer test in the assessment of community pulmonary embolism
Abstract Background D-dimer assays are sensitive but have poor specificity. False positive results lead to extra imaging and hospital admissions. Objectives To make a pilot comparison of the diagnostic accuracy of the standard quantitative latex HemosIL D-dimer assay with a newer HemosIL D-dimer HS...
Saved in:
Published in: | Thrombosis research 2009-06, Vol.124 (2), p.230-235 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract Background D-dimer assays are sensitive but have poor specificity. False positive results lead to extra imaging and hospital admissions. Objectives To make a pilot comparison of the diagnostic accuracy of the standard quantitative latex HemosIL D-dimer assay with a newer HemosIL D-dimer HS version designed to have improved specificity. Patients / Methods Consecutive patients presenting from the community to an Emergency Department that were investigated for suspected pulmonary embolism using a D-dimer test were included in the study. Standard and D-dimer HS tests were performed. Pulmonary Embolism was diagnosed on the basis of imaging studies or post-mortem at any time from presentation to 90 days thereafter. Results The prevalence of Pulmonary Embolism was 4.5% (18/402). The sensitivity, specificity, negative predictive value, and positive predictive value for the standard quantitative D-dimer test was 100% (81.5 – 100.0), 49.2% (44.1 – 54.3),100% (98.1 – 100.0), and 8.5% (5.1 – 13.0), respectively, and 100% (81.5 – 100.0), 58.3% (53.2 – 63.3),100% (98.4 – 100.0), and 10.1% (6.1 – 15.5), for the D-dimer HS test. There were 35 (16%) fewer ‘false positives’ using the D-dimer HS assay compared with the standard assay. Conclusions D-dimer HS has superior specificity to the standard quantitative D-dimer test without any loss of sensitivity. The generation of fewer false positive results should lead to less unnecessary diagnostic imaging; the use of which is associated with increased hospital admissions and length of stay. The HS assay may therefore have significant health economic benefits. |
---|---|
ISSN: | 0049-3848 1879-2472 |
DOI: | 10.1016/j.thromres.2008.10.018 |