Loading…
Bipyridine- and Copper-Functionalized N‑doped Carbon Dots for Fluorescence Turn Off–On Detection of Ciprofloxacin
Herein, a fluorescence turn off–on nanosensor has been successfully developed using functionalized N-doped carbon dots (N-CDs) as the label-free sensing probe for the ultrasensitive detection of Cu2+ ions first and then ciprofloxacin (CIP), one of the most commonly used antibiotics for disease contr...
Saved in:
Published in: | ACS applied materials & interfaces 2020-07, Vol.12 (29), p.32247-32258 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Herein, a fluorescence turn off–on nanosensor has been successfully developed using functionalized N-doped carbon dots (N-CDs) as the label-free sensing probe for the ultrasensitive detection of Cu2+ ions first and then ciprofloxacin (CIP), one of the most commonly used antibiotics for disease control, in the presence of bipyridine. The homogeneous and narrowly distributed N-CDs with a mean size of 5.7 nm and a high quantum yield of 84% are fabricated via the hydrothermal method in the presence of citric acid and ethylenediamine as the carbon and nitrogen sources, respectively. The Cu2+ ions serve as both analyte and fluorescence quenchers in the sensing platform of N-CDs, and a good linear response to Cu2+ in the range of 0.01–0.35 μM with a limit of detection (LOD) of 0.076 nM is observed. Then, 0.35 μM Cu2+ is used as the fluorescence quencher of N-CDs to build up the fluorescence turn off–on sensing probe for the detection of CIP using bipyridine (bipy) as the linker for CIP and Cu2+ ions. The addition of CIP to the bipy-Cu@N-CD composites triggers the formation of CIP-bipy-Cu conjugate as well as the release of N-CDs, resulting in the recovery of fluorescence intensity after 6 min of incubation. The sensing probe exhibits a two-phase linear response to CIP in the concentration range of 0.05–1 and 1–50 μM with a LOD of 0.4 nM. In addition, the bipy-Cu@N-CD probe shows high sensitivity toward CIP over the 19 other interferences. Good recovery of 96–110% is also observed when 0.1–0.9 μM CIP is spiked into the real samples. Results obtained in this study clearly demonstrate a newly developed sensing platform with rapid detection of metal ions and antibiotics, which can open an avenue to develop highly efficient and robust sensing probes for the detection of metal ions, organic metabolites, and biomarkers in biological applications. |
---|---|
ISSN: | 1944-8244 1944-8252 |
DOI: | 10.1021/acsami.0c04645 |