Loading…

SERS-Based Lateral Flow Immunoassay Combined with Enzymatic Recombinase Amplification for Quantitative, High-Sensitive Detection of Influenza A Virus

Accurate and convenient diagnosis of the influenza virus is of critical importance to prevent the spread of flu infections and guide therapy and treatment. This work reports the fabrication of a sensitive and quantitative surface-enhanced Raman scattering (SERS)-based lateral flow (LF) strip combine...

Full description

Saved in:
Bibliographic Details
Published in:ACS applied nano materials 2024-02, Vol.7 (3), p.3373-3384
Main Authors: Zhu, Chu-shu, Xiong, Siyue, Wang, Chengxuan, Dong, Peitao, Wu, Xuezhong
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Accurate and convenient diagnosis of the influenza virus is of critical importance to prevent the spread of flu infections and guide therapy and treatment. This work reports the fabrication of a sensitive and quantitative surface-enhanced Raman scattering (SERS)-based lateral flow (LF) strip combined with enzymatic recombinase amplification (ERA) for the highly effective detection of the influenza A virus. Gold-shell silica-core nanoraspberries (NRbs) were used in this SERS-LF strip as a SERS substrate. Practical and convenient detection was accomplished by naked-eye visualization, and highly sensitive quantitative detection was accomplished by monitoring the intensity of the distinct Raman peaks associated with the SERS tags. Under optimal conditions, the sensitivity of this ERA-SERS-LF strip for the DNA standard of the IAV matrix gene is 105 copies/mL by naked-eye visualization, and the limit of detection (LOD) was estimated to be 2.63 × 103 copies/mL by SERS detection, lowered by nearly 40 times compared with visual results due to the signal enhancement of the SERS tags. Besides, quantitative detection for the DNA standard of the IAV matrix gene was obtained with a wide linear range (2.63 × 103 copies/mL to 109 copies/mL). Pseudoviruses of IAV and other respiratory viruses could be successfully identified by using the fabricated ERA-SERS-LF strip. Overall, the findings of this study demonstrate the prospects of the use of the ERA-SERS-LF strip as an effective tool for point-of-care testing (POCT) detection of viruses by virtue of its portability, good sensitivity, quantitative detection ability, and outstanding specificity.
ISSN:2574-0970
2574-0970
DOI:10.1021/acsanm.3c05922