Even‐Order Harmonic Distortion Observations During Multiple Geomagnetic Disturbances: Investigation From New Zealand

Large geomagnetic storms are a space weather hazard to power transmission networks due to the effects of Geomagnetically Induced Currents (GICs). GIC can negatively impact power transmission systems through the generation of even‐order current and voltage harmonics due to half‐cycle transformer satu...

Full description

Saved in:
Bibliographic Details
Published in:Space weather 2024-05, Vol.22 (5), p.n/a
Main Authors: Crack, Malcolm, Rodger, Craig J., Clilverd, Mark A., Mac Manus, Daniel H., Martin, Ian, Dalzell, Michael, Subritzky, Soren P., Watson, Neville R., Petersen, Tanja
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Large geomagnetic storms are a space weather hazard to power transmission networks due to the effects of Geomagnetically Induced Currents (GICs). GIC can negatively impact power transmission systems through the generation of even‐order current and voltage harmonics due to half‐cycle transformer saturation. This study investigates a decade of even‐order voltage total harmonic distortion (hereon referred to as Even‐Order Total Harmonic Distortion (ETHD)) observations provided by Transpower New Zealand Ltd., the national system operator. We make use of ETHD measurements at 139 locations throughout New Zealand, monitored at 377 separate circuit breakers, focusing on 10 large geomagnetic disturbances during the period 2013–2023. Analysis identified 5 key substations, which appeared to act as sources of ETHD. The majority of these substations include single phase transformer banks, and evidence of significant GIC magnitudes. The ETHD from the source substations was found to propagate into the surrounding network, with the percentage distortion typically decaying away over distances of 150–200 km locally, that is, at a rate of −0.0043 %km−1. During the study period some significant changes occurred in the power network, that is, removal of the Halfway Bush (HWB) single phase bank transformer T4 in November 2017, and decommissioning of the New Plymouth substation in December 2019. Decommissioning of these two assets resulted in less ETHD occurring in the surrounding regions during subsequent geomagnetic storms. However, ETHD still increased at HWB with increasing levels of GIC, indicating that three phase transformer units were still susceptible to saturation, albeit with about 1/3 of the ETHD percentage exhibited by single phase transformers. Plain Language Summary Space weather, triggered by solar storms, can lead to significant variations in the Earth's magnetic field. The magnetic variations are termed geomagnetic disturbances. Changing magnetic fields induce electric fields at the Earth's surface, causing unwanted currents to flow in electrical power transmission networks. These Geomagnetically Induced Currents (GICs), pose a hazard to network operations as they can cause networks to become destabilized, leading to blackouts and damage to transformers. One negative impact of GIC in a power network is the production of harmonics of the power transmission frequency (typically 50 or 60 Hz); such harmonics contributed to the blackout of the Québec power system in
ISSN:1542-7390
1542-7390
DOI:10.1029/2024SW003879