Loading…
Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema
Objective: To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. Design: Animal experimental study. Setting: Animal experimental laboratory. Participants: Swine (n = 23) weighing 26.4 ± 2.47 kg (mean ± SD). Interventions: The animals were anest...
Saved in:
Published in: | Journal of cardiothoracic and vascular anesthesia 2002-06, Vol.16 (3), p.334-337 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33 |
---|---|
cites | cdi_FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33 |
container_end_page | 337 |
container_issue | 3 |
container_start_page | 334 |
container_title | Journal of cardiothoracic and vascular anesthesia |
container_volume | 16 |
creator | Kurita, Tadayoshi Morita, Koji Kawasaki, Hiroyuki Fujii, Kiyoyasu Kazama, Tomiei Sato, Shigehito |
description | Objective: To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. Design: Animal experimental study. Setting: Animal experimental laboratory. Participants: Swine (n = 23) weighing 26.4 ± 2.47 kg (mean ± SD). Interventions: The animals were anesthetized and tracheotomized, then a pulmonary artery catheter was inserted into the right jugular vein, and a catheter (18G) was placed in the femoral artery. After median sternotomy and pericardiotomy, a left ventricular catheter (18G) was directly inserted. CO was measured by giving a bolus injection of lithium chloride into either the right atrium or the left ventricle in each animal. After control measurements, permeability pulmonary edema was initiated by infusing oleic acid into the central vein (injury). About 2 hours after oleic acid infusion, CO measurements were repeated in the same manner as the control measurement had been taken. Measurements and Main Results: Under each condition, right atrium lithium injection was similar to left ventricle lithium injection. The mean of these differences at injury (−0.06 ± 0.55 L/min) was the same as that at control (−0.05 ± 0.36 L/min). Conclusions: Although the variability of lithium dilution CO measurement after oleic acid–induced pulmonary edema was greater than that of the control, this technique was acceptable even in cases of lung injury. Copyright 2002, Elsevier Science (USA). All rights reserved. |
doi_str_mv | 10.1053/jcan.2002.124143 |
format | article |
fullrecord | <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1053_jcan_2002_124143</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1053077002000125</els_id><sourcerecordid>S1053077002000125</sourcerecordid><originalsourceid>FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33</originalsourceid><addsrcrecordid>eNp1kMtKAzEUhoMotlb3riQbl1NzmUxm3EnxBgUX6jqcSTKYMpeSTAR3voNv6JOYMoWuXCU5fH_4z4fQJSVLSgS_2Wjol4wQtqQspzk_QnMqOMvKnLHjdE9MRqQkM3QWwoYQSoWQp2hGGZGckWKOXtdu_HCxw8a1cXRDjzV440DjIY7bOOLOQojedrYfsevx0FqnMWhnfr9_XG-itgZvY9sNPfgvbI3t4BydNNAGe7E_F-j94f5t9ZStXx6fV3frTHNZjJmomeGgoSgrUeSmEZrpilWS1Hme-jWcV2nKC8hra6HmXJaikobRqilBpPcCkelf7YcQvG3U1rsu1VCUqN3uaudH7fyoyU-KXE2Rbaw7aw6BvZAEXO8BCBraxkOvXThwXApSEpa424mzacFPZ70K2tk-2XDe6lGZwf3f4g_RO4Nb</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema</title><source>Elsevier</source><creator>Kurita, Tadayoshi ; Morita, Koji ; Kawasaki, Hiroyuki ; Fujii, Kiyoyasu ; Kazama, Tomiei ; Sato, Shigehito</creator><creatorcontrib>Kurita, Tadayoshi ; Morita, Koji ; Kawasaki, Hiroyuki ; Fujii, Kiyoyasu ; Kazama, Tomiei ; Sato, Shigehito</creatorcontrib><description>Objective: To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. Design: Animal experimental study. Setting: Animal experimental laboratory. Participants: Swine (n = 23) weighing 26.4 ± 2.47 kg (mean ± SD). Interventions: The animals were anesthetized and tracheotomized, then a pulmonary artery catheter was inserted into the right jugular vein, and a catheter (18G) was placed in the femoral artery. After median sternotomy and pericardiotomy, a left ventricular catheter (18G) was directly inserted. CO was measured by giving a bolus injection of lithium chloride into either the right atrium or the left ventricle in each animal. After control measurements, permeability pulmonary edema was initiated by infusing oleic acid into the central vein (injury). About 2 hours after oleic acid infusion, CO measurements were repeated in the same manner as the control measurement had been taken. Measurements and Main Results: Under each condition, right atrium lithium injection was similar to left ventricle lithium injection. The mean of these differences at injury (−0.06 ± 0.55 L/min) was the same as that at control (−0.05 ± 0.36 L/min). Conclusions: Although the variability of lithium dilution CO measurement after oleic acid–induced pulmonary edema was greater than that of the control, this technique was acceptable even in cases of lung injury. Copyright 2002, Elsevier Science (USA). All rights reserved.</description><identifier>ISSN: 1053-0770</identifier><identifier>EISSN: 1532-8422</identifier><identifier>DOI: 10.1053/jcan.2002.124143</identifier><identifier>PMID: 12073206</identifier><language>eng</language><publisher>Philadelphia, PA: Elsevier Inc</publisher><subject>Animals ; Biological and medical sciences ; Cardiac Catheterization ; Cardiac Output ; cardiac output (CO) ; Cardiovascular system ; Catheterization, Swan-Ganz ; critical care ; Heart Atria ; Heart Ventricles ; indicator dilution ; Indicator Dilution Techniques ; Investigative techniques of hemodynamics ; Investigative techniques, diagnostic techniques (general aspects) ; Lithium Chloride ; lithium dilution ; lung injury ; measurement technique ; Medical sciences ; Oleic Acid ; pulmonary artery catheter ; pulmonary edema ; Pulmonary Edema - chemically induced ; Pulmonary Edema - physiopathology ; Swine ; thermodilution</subject><ispartof>Journal of cardiothoracic and vascular anesthesia, 2002-06, Vol.16 (3), p.334-337</ispartof><rights>2002</rights><rights>2002 INIST-CNRS</rights><rights>Copyright 2002, Elsevier Science (USA). All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33</citedby><cites>FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=13750802$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12073206$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kurita, Tadayoshi</creatorcontrib><creatorcontrib>Morita, Koji</creatorcontrib><creatorcontrib>Kawasaki, Hiroyuki</creatorcontrib><creatorcontrib>Fujii, Kiyoyasu</creatorcontrib><creatorcontrib>Kazama, Tomiei</creatorcontrib><creatorcontrib>Sato, Shigehito</creatorcontrib><title>Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema</title><title>Journal of cardiothoracic and vascular anesthesia</title><addtitle>J Cardiothorac Vasc Anesth</addtitle><description>Objective: To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. Design: Animal experimental study. Setting: Animal experimental laboratory. Participants: Swine (n = 23) weighing 26.4 ± 2.47 kg (mean ± SD). Interventions: The animals were anesthetized and tracheotomized, then a pulmonary artery catheter was inserted into the right jugular vein, and a catheter (18G) was placed in the femoral artery. After median sternotomy and pericardiotomy, a left ventricular catheter (18G) was directly inserted. CO was measured by giving a bolus injection of lithium chloride into either the right atrium or the left ventricle in each animal. After control measurements, permeability pulmonary edema was initiated by infusing oleic acid into the central vein (injury). About 2 hours after oleic acid infusion, CO measurements were repeated in the same manner as the control measurement had been taken. Measurements and Main Results: Under each condition, right atrium lithium injection was similar to left ventricle lithium injection. The mean of these differences at injury (−0.06 ± 0.55 L/min) was the same as that at control (−0.05 ± 0.36 L/min). Conclusions: Although the variability of lithium dilution CO measurement after oleic acid–induced pulmonary edema was greater than that of the control, this technique was acceptable even in cases of lung injury. Copyright 2002, Elsevier Science (USA). All rights reserved.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Cardiac Catheterization</subject><subject>Cardiac Output</subject><subject>cardiac output (CO)</subject><subject>Cardiovascular system</subject><subject>Catheterization, Swan-Ganz</subject><subject>critical care</subject><subject>Heart Atria</subject><subject>Heart Ventricles</subject><subject>indicator dilution</subject><subject>Indicator Dilution Techniques</subject><subject>Investigative techniques of hemodynamics</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Lithium Chloride</subject><subject>lithium dilution</subject><subject>lung injury</subject><subject>measurement technique</subject><subject>Medical sciences</subject><subject>Oleic Acid</subject><subject>pulmonary artery catheter</subject><subject>pulmonary edema</subject><subject>Pulmonary Edema - chemically induced</subject><subject>Pulmonary Edema - physiopathology</subject><subject>Swine</subject><subject>thermodilution</subject><issn>1053-0770</issn><issn>1532-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNp1kMtKAzEUhoMotlb3riQbl1NzmUxm3EnxBgUX6jqcSTKYMpeSTAR3voNv6JOYMoWuXCU5fH_4z4fQJSVLSgS_2Wjol4wQtqQspzk_QnMqOMvKnLHjdE9MRqQkM3QWwoYQSoWQp2hGGZGckWKOXtdu_HCxw8a1cXRDjzV440DjIY7bOOLOQojedrYfsevx0FqnMWhnfr9_XG-itgZvY9sNPfgvbI3t4BydNNAGe7E_F-j94f5t9ZStXx6fV3frTHNZjJmomeGgoSgrUeSmEZrpilWS1Hme-jWcV2nKC8hra6HmXJaikobRqilBpPcCkelf7YcQvG3U1rsu1VCUqN3uaudH7fyoyU-KXE2Rbaw7aw6BvZAEXO8BCBraxkOvXThwXApSEpa424mzacFPZ70K2tk-2XDe6lGZwf3f4g_RO4Nb</recordid><startdate>20020601</startdate><enddate>20020601</enddate><creator>Kurita, Tadayoshi</creator><creator>Morita, Koji</creator><creator>Kawasaki, Hiroyuki</creator><creator>Fujii, Kiyoyasu</creator><creator>Kazama, Tomiei</creator><creator>Sato, Shigehito</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20020601</creationdate><title>Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema</title><author>Kurita, Tadayoshi ; Morita, Koji ; Kawasaki, Hiroyuki ; Fujii, Kiyoyasu ; Kazama, Tomiei ; Sato, Shigehito</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Cardiac Catheterization</topic><topic>Cardiac Output</topic><topic>cardiac output (CO)</topic><topic>Cardiovascular system</topic><topic>Catheterization, Swan-Ganz</topic><topic>critical care</topic><topic>Heart Atria</topic><topic>Heart Ventricles</topic><topic>indicator dilution</topic><topic>Indicator Dilution Techniques</topic><topic>Investigative techniques of hemodynamics</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Lithium Chloride</topic><topic>lithium dilution</topic><topic>lung injury</topic><topic>measurement technique</topic><topic>Medical sciences</topic><topic>Oleic Acid</topic><topic>pulmonary artery catheter</topic><topic>pulmonary edema</topic><topic>Pulmonary Edema - chemically induced</topic><topic>Pulmonary Edema - physiopathology</topic><topic>Swine</topic><topic>thermodilution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kurita, Tadayoshi</creatorcontrib><creatorcontrib>Morita, Koji</creatorcontrib><creatorcontrib>Kawasaki, Hiroyuki</creatorcontrib><creatorcontrib>Fujii, Kiyoyasu</creatorcontrib><creatorcontrib>Kazama, Tomiei</creatorcontrib><creatorcontrib>Sato, Shigehito</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Journal of cardiothoracic and vascular anesthesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kurita, Tadayoshi</au><au>Morita, Koji</au><au>Kawasaki, Hiroyuki</au><au>Fujii, Kiyoyasu</au><au>Kazama, Tomiei</au><au>Sato, Shigehito</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema</atitle><jtitle>Journal of cardiothoracic and vascular anesthesia</jtitle><addtitle>J Cardiothorac Vasc Anesth</addtitle><date>2002-06-01</date><risdate>2002</risdate><volume>16</volume><issue>3</issue><spage>334</spage><epage>337</epage><pages>334-337</pages><issn>1053-0770</issn><eissn>1532-8422</eissn><abstract>Objective: To determine whether lung injury influences the accuracy of lithium dilution cardiac output (CO) measurement. Design: Animal experimental study. Setting: Animal experimental laboratory. Participants: Swine (n = 23) weighing 26.4 ± 2.47 kg (mean ± SD). Interventions: The animals were anesthetized and tracheotomized, then a pulmonary artery catheter was inserted into the right jugular vein, and a catheter (18G) was placed in the femoral artery. After median sternotomy and pericardiotomy, a left ventricular catheter (18G) was directly inserted. CO was measured by giving a bolus injection of lithium chloride into either the right atrium or the left ventricle in each animal. After control measurements, permeability pulmonary edema was initiated by infusing oleic acid into the central vein (injury). About 2 hours after oleic acid infusion, CO measurements were repeated in the same manner as the control measurement had been taken. Measurements and Main Results: Under each condition, right atrium lithium injection was similar to left ventricle lithium injection. The mean of these differences at injury (−0.06 ± 0.55 L/min) was the same as that at control (−0.05 ± 0.36 L/min). Conclusions: Although the variability of lithium dilution CO measurement after oleic acid–induced pulmonary edema was greater than that of the control, this technique was acceptable even in cases of lung injury. Copyright 2002, Elsevier Science (USA). All rights reserved.</abstract><cop>Philadelphia, PA</cop><pub>Elsevier Inc</pub><pmid>12073206</pmid><doi>10.1053/jcan.2002.124143</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1053-0770 |
ispartof | Journal of cardiothoracic and vascular anesthesia, 2002-06, Vol.16 (3), p.334-337 |
issn | 1053-0770 1532-8422 |
language | eng |
recordid | cdi_crossref_primary_10_1053_jcan_2002_124143 |
source | Elsevier |
subjects | Animals Biological and medical sciences Cardiac Catheterization Cardiac Output cardiac output (CO) Cardiovascular system Catheterization, Swan-Ganz critical care Heart Atria Heart Ventricles indicator dilution Indicator Dilution Techniques Investigative techniques of hemodynamics Investigative techniques, diagnostic techniques (general aspects) Lithium Chloride lithium dilution lung injury measurement technique Medical sciences Oleic Acid pulmonary artery catheter pulmonary edema Pulmonary Edema - chemically induced Pulmonary Edema - physiopathology Swine thermodilution |
title | Lithium dilution cardiac output measurement in oleic acid–induced pulmonary edema |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T13%3A54%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Lithium%20dilution%20cardiac%20output%20measurement%20in%20oleic%20acid%E2%80%93induced%20pulmonary%20edema&rft.jtitle=Journal%20of%20cardiothoracic%20and%20vascular%20anesthesia&rft.au=Kurita,%20Tadayoshi&rft.date=2002-06-01&rft.volume=16&rft.issue=3&rft.spage=334&rft.epage=337&rft.pages=334-337&rft.issn=1053-0770&rft.eissn=1532-8422&rft_id=info:doi/10.1053/jcan.2002.124143&rft_dat=%3Celsevier_cross%3ES1053077002000125%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c376t-5b2d3aca689564df5c2c92970b44207f3394df36a4beeab3378597d219f8a5b33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/12073206&rfr_iscdi=true |