Loading…
Multi‐sample negative ion source
A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplifi...
Saved in:
Published in: | Review of Scientific Instruments 1996-03, Vol.67 (3), p.1230-1232 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673 |
---|---|
cites | cdi_FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673 |
container_end_page | 1232 |
container_issue | 3 |
container_start_page | 1230 |
container_title | Review of Scientific Instruments |
container_volume | 67 |
creator | Gelbart, W. Z. Johnson, R. R. Paul, M. Shahar, Y. Schubank, R. B. Cifarelli, F. |
description | A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplified target insulation. A pneumatically actuated target changer contains a 28‐sample wheel but allows manual placing of single samples as well. In initial runs the source produced over 1 μA of 40CaH−
3 and .25 μA of 27Al− beams. The construction of the source and the operation of the sample changer are discussed in this article. |
doi_str_mv | 10.1063/1.1146741 |
format | article |
fullrecord | <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1146741</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673</originalsourceid><addsrcrecordid>eNqdj8tKw0AYhQdRMFYXvkFwp5D6_5nMJUspXgotbnQ9TOYiI2kSZtKCOx_BZ_RJjLTg3rM5cPg4nEPIJcIcgdNbnCNWXFR4RDIEWReCl_SYZAC0KqZcnpKzlN5hEkPMyNV6247h-_Mr6c3Qurxzb3oMO5eHvstTv43GnZMTr9vkLg4-I68P9y-Lp2L1_Lhc3K0KQ0s6Fp5ZUVrLNVBpdOOF95o7IXTJnDVQN6XlxtRALZWOM80aw7iQEisvAbmgM3K97zWxTyk6r4YYNjp-KAT1e06hOpyb2Js9m0wYp8F99z9418c_UA3W0x8S0F2e</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Multi‐sample negative ion source</title><source>AIP - American Institute of Physics</source><source>AIP_美国物理联合会期刊回溯(NSTL购买)</source><creator>Gelbart, W. Z. ; Johnson, R. R. ; Paul, M. ; Shahar, Y. ; Schubank, R. B. ; Cifarelli, F.</creator><creatorcontrib>Gelbart, W. Z. ; Johnson, R. R. ; Paul, M. ; Shahar, Y. ; Schubank, R. B. ; Cifarelli, F.</creatorcontrib><description>A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplified target insulation. A pneumatically actuated target changer contains a 28‐sample wheel but allows manual placing of single samples as well. In initial runs the source produced over 1 μA of 40CaH−
3 and .25 μA of 27Al− beams. The construction of the source and the operation of the sample changer are discussed in this article.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1146741</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of Scientific Instruments, 1996-03, Vol.67 (3), p.1230-1232</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673</citedby><cites>FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1146741$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,776,778,780,785,786,791,1553,23909,23910,25118,27901,27902,76125,76132</link.rule.ids></links><search><creatorcontrib>Gelbart, W. Z.</creatorcontrib><creatorcontrib>Johnson, R. R.</creatorcontrib><creatorcontrib>Paul, M.</creatorcontrib><creatorcontrib>Shahar, Y.</creatorcontrib><creatorcontrib>Schubank, R. B.</creatorcontrib><creatorcontrib>Cifarelli, F.</creatorcontrib><title>Multi‐sample negative ion source</title><title>Review of Scientific Instruments</title><description>A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplified target insulation. A pneumatically actuated target changer contains a 28‐sample wheel but allows manual placing of single samples as well. In initial runs the source produced over 1 μA of 40CaH−
3 and .25 μA of 27Al− beams. The construction of the source and the operation of the sample changer are discussed in this article.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNqdj8tKw0AYhQdRMFYXvkFwp5D6_5nMJUspXgotbnQ9TOYiI2kSZtKCOx_BZ_RJjLTg3rM5cPg4nEPIJcIcgdNbnCNWXFR4RDIEWReCl_SYZAC0KqZcnpKzlN5hEkPMyNV6247h-_Mr6c3Qurxzb3oMO5eHvstTv43GnZMTr9vkLg4-I68P9y-Lp2L1_Lhc3K0KQ0s6Fp5ZUVrLNVBpdOOF95o7IXTJnDVQN6XlxtRALZWOM80aw7iQEisvAbmgM3K97zWxTyk6r4YYNjp-KAT1e06hOpyb2Js9m0wYp8F99z9418c_UA3W0x8S0F2e</recordid><startdate>19960301</startdate><enddate>19960301</enddate><creator>Gelbart, W. Z.</creator><creator>Johnson, R. R.</creator><creator>Paul, M.</creator><creator>Shahar, Y.</creator><creator>Schubank, R. B.</creator><creator>Cifarelli, F.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19960301</creationdate><title>Multi‐sample negative ion source</title><author>Gelbart, W. Z. ; Johnson, R. R. ; Paul, M. ; Shahar, Y. ; Schubank, R. B. ; Cifarelli, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gelbart, W. Z.</creatorcontrib><creatorcontrib>Johnson, R. R.</creatorcontrib><creatorcontrib>Paul, M.</creatorcontrib><creatorcontrib>Shahar, Y.</creatorcontrib><creatorcontrib>Schubank, R. B.</creatorcontrib><creatorcontrib>Cifarelli, F.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gelbart, W. Z.</au><au>Johnson, R. R.</au><au>Paul, M.</au><au>Shahar, Y.</au><au>Schubank, R. B.</au><au>Cifarelli, F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multi‐sample negative ion source</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1996-03-01</date><risdate>1996</risdate><volume>67</volume><issue>3</issue><spage>1230</spage><epage>1232</epage><pages>1230-1232</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplified target insulation. A pneumatically actuated target changer contains a 28‐sample wheel but allows manual placing of single samples as well. In initial runs the source produced over 1 μA of 40CaH−
3 and .25 μA of 27Al− beams. The construction of the source and the operation of the sample changer are discussed in this article.</abstract><doi>10.1063/1.1146741</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of Scientific Instruments, 1996-03, Vol.67 (3), p.1230-1232 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_1146741 |
source | AIP - American Institute of Physics; AIP_美国物理联合会期刊回溯(NSTL购买) |
title | Multi‐sample negative ion source |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T12%3A05%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multi%E2%80%90sample%20negative%20ion%20source&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Gelbart,%20W.%20Z.&rft.date=1996-03-01&rft.volume=67&rft.issue=3&rft.spage=1230&rft.epage=1232&rft.pages=1230-1232&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1146741&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c323t-f5d72dd6a038cabf7ffa6e77a25edc09b2d6cc903d38e65a5bc5678814f801673%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |