The Dubna electron cyclotron resonance ion source DECRIS-14-2 was put into regular operation at the U-400M cyclotron in the beginning of 1995. During the past two years the source has produced a wide range of ion beams for physics experiments as well as for the testing of the beam transport lines an...

Full description

Saved in:
Bibliographic Details
Published in:Review of Scientific Instruments 1998-02, Vol.69 (2), p.662-664
Main Authors: Efremov, A., Behterev, V., Bogomolov, S. L., Kutner, V. B., Lebedev, A. N., Loginov, V. N., Yazvitsky, Y. Yu
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383
cites cdi_FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383
container_end_page 664
container_issue 2
container_start_page 662
container_title Review of Scientific Instruments
container_volume 69
creator Efremov, A.
Behterev, V.
Bogomolov, S. L.
Kutner, V. B.
Lebedev, A. N.
Loginov, V. N.
Yazvitsky, Y. Yu
description The Dubna electron cyclotron resonance ion source DECRIS-14-2 was put into regular operation at the U-400M cyclotron in the beginning of 1995. During the past two years the source has produced a wide range of ion beams for physics experiments as well as for the testing of the beam transport lines and the cyclotron itself. Ions of gases, such as He, N, O, Ne, and Ar were successfully delivered and accelerated in the cyclotron. The ion source has shown good performance especially in the case of middle charge state ions (e.g., 600 eμ A of Ar 8+ ) as well as high operational reliability. Significant progress in metal ion production has been achieved by introducing a new microoven for the evaporation of metal samples. This microoven in combination with an additional tantalum sheet installed inside the discharge chamber has made it possible to obtain Li 2+ ion beams in excess of 200 eμ A .
doi_str_mv 10.1063/1.1148567
format article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1148567</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383</originalsourceid><addsrcrecordid>eNqdj01LAzEYhIMouFYP_oO9VkjNm2TfTY-ytlooKH6cQz5xxTYlWQX_vSsteHcuA8PDMEPIJbAZMBTXMAOQqsH2iFTA1Jy2yMUxqRgTkmIr1Sk5K-WdjWoAKjJ9DDmmvDFbF-oU6-Et1H3a1iV95jG5XXRPq2cKkvJzchLNRwkXB5-Q1-Xipbun64e7VXezpo7P24FGRKeUN2CVRa9MMNwKJUEyE7mT3oqGW4YyWO7BucZjRBfBzQ1Hi0KJCZnue11OpeQQ9S73G5O_NTD9-1GDPnwc2as9W1w_mGEc_j_4K-U_UO98FD9ouV2w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Performance of the ion source DECRIS-14-2</title><source>American Institute of Physics</source><source>AIP Digital Archive</source><creator>Efremov, A. ; Behterev, V. ; Bogomolov, S. L. ; Kutner, V. B. ; Lebedev, A. N. ; Loginov, V. N. ; Yazvitsky, Y. Yu</creator><creatorcontrib>Efremov, A. ; Behterev, V. ; Bogomolov, S. L. ; Kutner, V. B. ; Lebedev, A. N. ; Loginov, V. N. ; Yazvitsky, Y. Yu</creatorcontrib><description>The Dubna electron cyclotron resonance ion source DECRIS-14-2 was put into regular operation at the U-400M cyclotron in the beginning of 1995. During the past two years the source has produced a wide range of ion beams for physics experiments as well as for the testing of the beam transport lines and the cyclotron itself. Ions of gases, such as He, N, O, Ne, and Ar were successfully delivered and accelerated in the cyclotron. The ion source has shown good performance especially in the case of middle charge state ions (e.g., 600 eμ A of Ar 8+ ) as well as high operational reliability. Significant progress in metal ion production has been achieved by introducing a new microoven for the evaporation of metal samples. This microoven in combination with an additional tantalum sheet installed inside the discharge chamber has made it possible to obtain Li 2+ ion beams in excess of 200 eμ A .</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1148567</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of Scientific Instruments, 1998-02, Vol.69 (2), p.662-664</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383</citedby><cites>FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1148567$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,782,784,789,790,795,1559,23930,23931,25140,27924,27925,76383,76390</link.rule.ids></links><search><creatorcontrib>Efremov, A.</creatorcontrib><creatorcontrib>Behterev, V.</creatorcontrib><creatorcontrib>Bogomolov, S. L.</creatorcontrib><creatorcontrib>Kutner, V. B.</creatorcontrib><creatorcontrib>Lebedev, A. N.</creatorcontrib><creatorcontrib>Loginov, V. N.</creatorcontrib><creatorcontrib>Yazvitsky, Y. Yu</creatorcontrib><title>Performance of the ion source DECRIS-14-2</title><title>Review of Scientific Instruments</title><description>The Dubna electron cyclotron resonance ion source DECRIS-14-2 was put into regular operation at the U-400M cyclotron in the beginning of 1995. During the past two years the source has produced a wide range of ion beams for physics experiments as well as for the testing of the beam transport lines and the cyclotron itself. Ions of gases, such as He, N, O, Ne, and Ar were successfully delivered and accelerated in the cyclotron. The ion source has shown good performance especially in the case of middle charge state ions (e.g., 600 eμ A of Ar 8+ ) as well as high operational reliability. Significant progress in metal ion production has been achieved by introducing a new microoven for the evaporation of metal samples. This microoven in combination with an additional tantalum sheet installed inside the discharge chamber has made it possible to obtain Li 2+ ion beams in excess of 200 eμ A .</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqdj01LAzEYhIMouFYP_oO9VkjNm2TfTY-ytlooKH6cQz5xxTYlWQX_vSsteHcuA8PDMEPIJbAZMBTXMAOQqsH2iFTA1Jy2yMUxqRgTkmIr1Sk5K-WdjWoAKjJ9DDmmvDFbF-oU6-Et1H3a1iV95jG5XXRPq2cKkvJzchLNRwkXB5-Q1-Xipbun64e7VXezpo7P24FGRKeUN2CVRa9MMNwKJUEyE7mT3oqGW4YyWO7BucZjRBfBzQ1Hi0KJCZnue11OpeQQ9S73G5O_NTD9-1GDPnwc2as9W1w_mGEc_j_4K-U_UO98FD9ouV2w</recordid><startdate>19980201</startdate><enddate>19980201</enddate><creator>Efremov, A.</creator><creator>Behterev, V.</creator><creator>Bogomolov, S. L.</creator><creator>Kutner, V. B.</creator><creator>Lebedev, A. N.</creator><creator>Loginov, V. N.</creator><creator>Yazvitsky, Y. Yu</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980201</creationdate><title>Performance of the ion source DECRIS-14-2</title><author>Efremov, A. ; Behterev, V. ; Bogomolov, S. L. ; Kutner, V. B. ; Lebedev, A. N. ; Loginov, V. N. ; Yazvitsky, Y. Yu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Efremov, A.</creatorcontrib><creatorcontrib>Behterev, V.</creatorcontrib><creatorcontrib>Bogomolov, S. L.</creatorcontrib><creatorcontrib>Kutner, V. B.</creatorcontrib><creatorcontrib>Lebedev, A. N.</creatorcontrib><creatorcontrib>Loginov, V. N.</creatorcontrib><creatorcontrib>Yazvitsky, Y. Yu</creatorcontrib><collection>CrossRef</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Efremov, A.</au><au>Behterev, V.</au><au>Bogomolov, S. L.</au><au>Kutner, V. B.</au><au>Lebedev, A. N.</au><au>Loginov, V. N.</au><au>Yazvitsky, Y. Yu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance of the ion source DECRIS-14-2</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1998-02-01</date><risdate>1998</risdate><volume>69</volume><issue>2</issue><spage>662</spage><epage>664</epage><pages>662-664</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The Dubna electron cyclotron resonance ion source DECRIS-14-2 was put into regular operation at the U-400M cyclotron in the beginning of 1995. During the past two years the source has produced a wide range of ion beams for physics experiments as well as for the testing of the beam transport lines and the cyclotron itself. Ions of gases, such as He, N, O, Ne, and Ar were successfully delivered and accelerated in the cyclotron. The ion source has shown good performance especially in the case of middle charge state ions (e.g., 600 eμ A of Ar 8+ ) as well as high operational reliability. Significant progress in metal ion production has been achieved by introducing a new microoven for the evaporation of metal samples. This microoven in combination with an additional tantalum sheet installed inside the discharge chamber has made it possible to obtain Li 2+ ion beams in excess of 200 eμ A .</abstract><doi>10.1063/1.1148567</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of Scientific Instruments, 1998-02, Vol.69 (2), p.662-664
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1148567
source American Institute of Physics; AIP Digital Archive
title Performance of the ion source DECRIS-14-2
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T08%3A15%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20of%20the%20ion%20source%20DECRIS-14-2&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Efremov,%20A.&rft.date=1998-02-01&rft.volume=69&rft.issue=2&rft.spage=662&rft.epage=664&rft.pages=662-664&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1148567&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c297t-f66c88da1b8b6d8aea2b384140af2c4db352b064eb2d1cc5d6f6cf1c9a26b6383%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true