Loading…
Study of the leakage field of magnetic force microscopy thin-film tips using electron holography
Electron holography is applied for the study of the leakage field of thin-film ferromagnetic tips used as probes in magnetic force microscopy. We used commercially available pyramidal tips covered on one face with a thin NiCo film, which were then placed in a high external magnetic field directed al...
Saved in:
Published in: | Applied physics letters 1996-03, Vol.68 (13), p.1865-1867 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Electron holography is applied for the study of the leakage field of thin-film ferromagnetic tips used as probes in magnetic force microscopy. We used commercially available pyramidal tips covered on one face with a thin NiCo film, which were then placed in a high external magnetic field directed along the pyramid axis. Good agreement between simulated and experimental electron phase difference maps allows to measure the local flux from the ferromagnetic tips and therefore to evaluate the perturbation induced by the microprobe stray field on the sample area. |
---|---|
ISSN: | 0003-6951 1077-3118 |
DOI: | 10.1063/1.116039 |