Loading…

PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR

Experiments are described in which a plasma is used as an impedance element in an active Fabry-Perot microwave resonator which contains a positive feedback loop. The arrangement functions as a Q multiplier or as an oscillator, with the plasma acting as a power or frequency-determining element. The c...

Full description

Saved in:
Bibliographic Details
Published in:Applied physics letters 1968-01, Vol.13 (3), p.96-98
Main Authors: Ajmera, R. C., Lashinsky, H.
Format: Article
Language:English
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c229t-44e20f724694890b6072265ec6a78b47036e5564d8630bab2f05c70bc1094ac93
cites
container_end_page 98
container_issue 3
container_start_page 96
container_title Applied physics letters
container_volume 13
creator Ajmera, R. C.
Lashinsky, H.
description Experiments are described in which a plasma is used as an impedance element in an active Fabry-Perot microwave resonator which contains a positive feedback loop. The arrangement functions as a Q multiplier or as an oscillator, with the plasma acting as a power or frequency-determining element. The characteristics of the active Fabry-Perot resonator are discussed in connection with diagnostic methods for pulsed and steady-state plasmas.
doi_str_mv 10.1063/1.1652531
format article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1652531</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1063_1_1652531</sourcerecordid><originalsourceid>FETCH-LOGICAL-c229t-44e20f724694890b6072265ec6a78b47036e5564d8630bab2f05c70bc1094ac93</originalsourceid><addsrcrecordid>eNotj81KxDAYRYMoWEcXvkG2LjJ-X36bZawZDfSPTlVclTa2oChK68a3t-LAhcs9iwuHkEuELYIW17hFrbgSeEQSBGOYQEyPSQIAgmmr8JScLcvbOhUXIiG-zt2-cDQUtb91Zeapz33hy5aGkro1WRsePd25m-aZ1b6pWlqErKme3Eobv69K11bNOTmZ-vdlvDj0hjzsfJvds7y6C5nLWeTcfjMpRw6T4VJbmVoYNBjOtRqj7k06SANCj0pp-ZJqAUM_8AlUNDBEBCv7aMWGXP3_xvlzWeZx6r7m149-_ukQuj__DruDv_gFKfpEbQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR</title><source>AIP Digital Archive</source><creator>Ajmera, R. C. ; Lashinsky, H.</creator><creatorcontrib>Ajmera, R. C. ; Lashinsky, H.</creatorcontrib><description>Experiments are described in which a plasma is used as an impedance element in an active Fabry-Perot microwave resonator which contains a positive feedback loop. The arrangement functions as a Q multiplier or as an oscillator, with the plasma acting as a power or frequency-determining element. The characteristics of the active Fabry-Perot resonator are discussed in connection with diagnostic methods for pulsed and steady-state plasmas.</description><identifier>ISSN: 0003-6951</identifier><identifier>EISSN: 1077-3118</identifier><identifier>DOI: 10.1063/1.1652531</identifier><language>eng</language><ispartof>Applied physics letters, 1968-01, Vol.13 (3), p.96-98</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c229t-44e20f724694890b6072265ec6a78b47036e5564d8630bab2f05c70bc1094ac93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Ajmera, R. C.</creatorcontrib><creatorcontrib>Lashinsky, H.</creatorcontrib><title>PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR</title><title>Applied physics letters</title><description>Experiments are described in which a plasma is used as an impedance element in an active Fabry-Perot microwave resonator which contains a positive feedback loop. The arrangement functions as a Q multiplier or as an oscillator, with the plasma acting as a power or frequency-determining element. The characteristics of the active Fabry-Perot resonator are discussed in connection with diagnostic methods for pulsed and steady-state plasmas.</description><issn>0003-6951</issn><issn>1077-3118</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1968</creationdate><recordtype>article</recordtype><recordid>eNotj81KxDAYRYMoWEcXvkG2LjJ-X36bZawZDfSPTlVclTa2oChK68a3t-LAhcs9iwuHkEuELYIW17hFrbgSeEQSBGOYQEyPSQIAgmmr8JScLcvbOhUXIiG-zt2-cDQUtb91Zeapz33hy5aGkro1WRsePd25m-aZ1b6pWlqErKme3Eobv69K11bNOTmZ-vdlvDj0hjzsfJvds7y6C5nLWeTcfjMpRw6T4VJbmVoYNBjOtRqj7k06SANCj0pp-ZJqAUM_8AlUNDBEBCv7aMWGXP3_xvlzWeZx6r7m149-_ukQuj__DruDv_gFKfpEbQ</recordid><startdate>19680101</startdate><enddate>19680101</enddate><creator>Ajmera, R. C.</creator><creator>Lashinsky, H.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19680101</creationdate><title>PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR</title><author>Ajmera, R. C. ; Lashinsky, H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c229t-44e20f724694890b6072265ec6a78b47036e5564d8630bab2f05c70bc1094ac93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1968</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ajmera, R. C.</creatorcontrib><creatorcontrib>Lashinsky, H.</creatorcontrib><collection>CrossRef</collection><jtitle>Applied physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ajmera, R. C.</au><au>Lashinsky, H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR</atitle><jtitle>Applied physics letters</jtitle><date>1968-01-01</date><risdate>1968</risdate><volume>13</volume><issue>3</issue><spage>96</spage><epage>98</epage><pages>96-98</pages><issn>0003-6951</issn><eissn>1077-3118</eissn><abstract>Experiments are described in which a plasma is used as an impedance element in an active Fabry-Perot microwave resonator which contains a positive feedback loop. The arrangement functions as a Q multiplier or as an oscillator, with the plasma acting as a power or frequency-determining element. The characteristics of the active Fabry-Perot resonator are discussed in connection with diagnostic methods for pulsed and steady-state plasmas.</abstract><doi>10.1063/1.1652531</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-6951
ispartof Applied physics letters, 1968-01, Vol.13 (3), p.96-98
issn 0003-6951
1077-3118
language eng
recordid cdi_crossref_primary_10_1063_1_1652531
source AIP Digital Archive
title PLASMA IMPEDANCE ELEMENT IN AN ACTIVE FABRY-PEROT MICROWAVE RESONATOR
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T19%3A49%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=PLASMA%20IMPEDANCE%20ELEMENT%20IN%20AN%20ACTIVE%20FABRY-PEROT%20MICROWAVE%20RESONATOR&rft.jtitle=Applied%20physics%20letters&rft.au=Ajmera,%20R.%20C.&rft.date=1968-01-01&rft.volume=13&rft.issue=3&rft.spage=96&rft.epage=98&rft.pages=96-98&rft.issn=0003-6951&rft.eissn=1077-3118&rft_id=info:doi/10.1063/1.1652531&rft_dat=%3Ccrossref%3E10_1063_1_1652531%3C/crossref%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c229t-44e20f724694890b6072265ec6a78b47036e5564d8630bab2f05c70bc1094ac93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true