Loading…
Simultaneous determination of the pretilt angle and the cell thickness of a liquid crystal cell
This paper presents a simple method for determining the pretilt angle and cell thickness simultaneously, which are critical factors in liquid crystal displays. Their determination was achieved from the incident angles, where the transmittance was the same for each cell rotation with crossed polarize...
Saved in:
Published in: | Journal of applied physics 2013-09, Vol.114 (12) |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper presents a simple method for determining the pretilt angle and cell thickness simultaneously, which are critical factors in liquid crystal displays. Their determination was achieved from the incident angles, where the transmittance was the same for each cell rotation with crossed polarizers and parallel polarizers, based on the crystal rotation method. Unlike the conventional crystal rotation method, which has a limited measurement range, the proposed method could cover all ranges of pretilt angles. |
---|---|
ISSN: | 0021-8979 1089-7550 |
DOI: | 10.1063/1.4824062 |