Loading…
The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources
The negative subjective reaction to light glare is generally referred to as the discomfort glare effect. The luminances and geometrical conditions that increase or decrease the level of subjective response have been studied extensively, and various formulae have been generated as guidelines for reco...
Saved in:
Published in: | Journal of the Illuminating Engineering Society 1996, Vol.25 (1), p.34-41 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303 |
---|---|
cites | cdi_FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303 |
container_end_page | 41 |
container_issue | 1 |
container_start_page | 34 |
container_title | Journal of the Illuminating Engineering Society |
container_volume | 25 |
creator | Berman, S.M. Bullimore, M.A. Bailey, I.L. Jacobs, R.J. |
description | The negative subjective reaction to light glare is generally referred to as the discomfort glare effect. The luminances and geometrical conditions that increase or decrease the level of subjective response have been studied extensively, and various formulae have been generated as guidelines for recommended lighting practice in both interior and exterior conditions. This paper uses both a variant of the traditional subjective scaling methodology and the electromyographical methodology to determine an objective correlate to the reported discomfort glare. Results for a wide range of luminaries show that the scotopically enhanced source produces less discomfort for both subjective and objective measures when compared to the scotopically deficient source. |
doi_str_mv | 10.1080/00994480.1996.10748131 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1080_00994480_1996_10748131</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>15715402</sourcerecordid><originalsourceid>FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303</originalsourceid><addsrcrecordid>eNqFUF1LwzAUzYOCc_oXJE--VW-aNm0ex9Q5GChsPocsTTSSNjVpkfnrTZl7Fi6c-3UO9x6EbgjcEajhHoDzoqhTxTlLraqoCSVnaDYNsmlygS5j_AQgOXCYodfdh8brzrhRd0pjb_C212oI0uGlb3sf7WB9h1M82Kh8a3wY8MrJoHFK8UaGd51t7Y_GWz8GpeMVOjfSRX39h3P09vS4Wz5nm5fVernYZKoo2ZDJikhGuVHUMFUlJLXeG0JoU-W6aWTO6B5UziSrgcu8ZA0pS8ITqyoYUKBzdHvU7YP_GnUcRJsO1M7JTvsxClJWpCwgT4vsuKiCjzFoI_pgWxkOgoCYTBMn08RkmjiZloiLI9F26dVWfvvgGjHIg_PBBNkpGwX9R-MXEC11Pw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15715402</pqid></control><display><type>article</type><title>The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources</title><source>Taylor & Francis Engineering, Computing & Technology Archive</source><creator>Berman, S.M. ; Bullimore, M.A. ; Bailey, I.L. ; Jacobs, R.J.</creator><creatorcontrib>Berman, S.M. ; Bullimore, M.A. ; Bailey, I.L. ; Jacobs, R.J.</creatorcontrib><description>The negative subjective reaction to light glare is generally referred to as the discomfort glare effect. The luminances and geometrical conditions that increase or decrease the level of subjective response have been studied extensively, and various formulae have been generated as guidelines for recommended lighting practice in both interior and exterior conditions. This paper uses both a variant of the traditional subjective scaling methodology and the electromyographical methodology to determine an objective correlate to the reported discomfort glare. Results for a wide range of luminaries show that the scotopically enhanced source produces less discomfort for both subjective and objective measures when compared to the scotopically deficient source.</description><identifier>ISSN: 0099-4480</identifier><identifier>DOI: 10.1080/00994480.1996.10748131</identifier><language>eng</language><publisher>Taylor & Francis</publisher><ispartof>Journal of the Illuminating Engineering Society, 1996, Vol.25 (1), p.34-41</ispartof><rights>Copyright 1996 Illuminating Engineering Society 1996</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303</citedby><cites>FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/00994480.1996.10748131$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/00994480.1996.10748131$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>314,778,782,4012,27910,27911,27912,59886,60675</link.rule.ids></links><search><creatorcontrib>Berman, S.M.</creatorcontrib><creatorcontrib>Bullimore, M.A.</creatorcontrib><creatorcontrib>Bailey, I.L.</creatorcontrib><creatorcontrib>Jacobs, R.J.</creatorcontrib><title>The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources</title><title>Journal of the Illuminating Engineering Society</title><description>The negative subjective reaction to light glare is generally referred to as the discomfort glare effect. The luminances and geometrical conditions that increase or decrease the level of subjective response have been studied extensively, and various formulae have been generated as guidelines for recommended lighting practice in both interior and exterior conditions. This paper uses both a variant of the traditional subjective scaling methodology and the electromyographical methodology to determine an objective correlate to the reported discomfort glare. Results for a wide range of luminaries show that the scotopically enhanced source produces less discomfort for both subjective and objective measures when compared to the scotopically deficient source.</description><issn>0099-4480</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNqFUF1LwzAUzYOCc_oXJE--VW-aNm0ex9Q5GChsPocsTTSSNjVpkfnrTZl7Fi6c-3UO9x6EbgjcEajhHoDzoqhTxTlLraqoCSVnaDYNsmlygS5j_AQgOXCYodfdh8brzrhRd0pjb_C212oI0uGlb3sf7WB9h1M82Kh8a3wY8MrJoHFK8UaGd51t7Y_GWz8GpeMVOjfSRX39h3P09vS4Wz5nm5fVernYZKoo2ZDJikhGuVHUMFUlJLXeG0JoU-W6aWTO6B5UziSrgcu8ZA0pS8ITqyoYUKBzdHvU7YP_GnUcRJsO1M7JTvsxClJWpCwgT4vsuKiCjzFoI_pgWxkOgoCYTBMn08RkmjiZloiLI9F26dVWfvvgGjHIg_PBBNkpGwX9R-MXEC11Pw</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Berman, S.M.</creator><creator>Bullimore, M.A.</creator><creator>Bailey, I.L.</creator><creator>Jacobs, R.J.</creator><general>Taylor & Francis</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>1996</creationdate><title>The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources</title><author>Berman, S.M. ; Bullimore, M.A. ; Bailey, I.L. ; Jacobs, R.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Berman, S.M.</creatorcontrib><creatorcontrib>Bullimore, M.A.</creatorcontrib><creatorcontrib>Bailey, I.L.</creatorcontrib><creatorcontrib>Jacobs, R.J.</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of the Illuminating Engineering Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Berman, S.M.</au><au>Bullimore, M.A.</au><au>Bailey, I.L.</au><au>Jacobs, R.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources</atitle><jtitle>Journal of the Illuminating Engineering Society</jtitle><date>1996</date><risdate>1996</risdate><volume>25</volume><issue>1</issue><spage>34</spage><epage>41</epage><pages>34-41</pages><issn>0099-4480</issn><abstract>The negative subjective reaction to light glare is generally referred to as the discomfort glare effect. The luminances and geometrical conditions that increase or decrease the level of subjective response have been studied extensively, and various formulae have been generated as guidelines for recommended lighting practice in both interior and exterior conditions. This paper uses both a variant of the traditional subjective scaling methodology and the electromyographical methodology to determine an objective correlate to the reported discomfort glare. Results for a wide range of luminaries show that the scotopically enhanced source produces less discomfort for both subjective and objective measures when compared to the scotopically deficient source.</abstract><pub>Taylor & Francis</pub><doi>10.1080/00994480.1996.10748131</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0099-4480 |
ispartof | Journal of the Illuminating Engineering Society, 1996, Vol.25 (1), p.34-41 |
issn | 0099-4480 |
language | eng |
recordid | cdi_crossref_primary_10_1080_00994480_1996_10748131 |
source | Taylor & Francis Engineering, Computing & Technology Archive |
title | The Influence of Spectral Composition on Discomfort Glare for Large-Size Sources |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T14%3A14%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Influence%20of%20Spectral%20Composition%20on%20Discomfort%20Glare%20for%20Large-Size%20Sources&rft.jtitle=Journal%20of%20the%20Illuminating%20Engineering%20Society&rft.au=Berman,%20S.M.&rft.date=1996&rft.volume=25&rft.issue=1&rft.spage=34&rft.epage=41&rft.pages=34-41&rft.issn=0099-4480&rft_id=info:doi/10.1080/00994480.1996.10748131&rft_dat=%3Cproquest_cross%3E15715402%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c456t-a71a639fc3f6c79fc18ebf113d72edda263b0c26a6809a256d1551971a7460303%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=15715402&rft_id=info:pmid/&rfr_iscdi=true |