Loading…

Thermal analysis of an electric power transformer inside an enclosure - a case study

Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under d...

Full description

Saved in:
Bibliographic Details
Published in:International journal of ambient energy 2017-04, Vol.38 (3), p.250-258
Main Authors: Abdolzadeh, M., Khoshabi, A., Mehrabian, M.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243
cites cdi_FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243
container_end_page 258
container_issue 3
container_start_page 250
container_title International journal of ambient energy
container_volume 38
creator Abdolzadeh, M.
Khoshabi, A.
Mehrabian, M.A.
description Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under different operating conditions. The experimental data were collected while the transformer was working in real operating conditions. The 3D numerical analysis was conducted and then verified with the experimental data. The results of this study show that despite lower power loss of the transformer, compared to the conventional transformers which are commonly installed on the overhead power line towers, the enclosure of the transformer has a serious problem of poor ventilation and it causes the transformer to run at higher temperature condition and this consequently decreases the transformer's efficiency. However, this problem can be fixed by implementing some changes in the enclosure's air vents and also by adding a fan on the roof of the enclosure.
doi_str_mv 10.1080/01430750.2015.1086678
format article
fullrecord <record><control><sourceid>crossref_infor</sourceid><recordid>TN_cdi_crossref_primary_10_1080_01430750_2015_1086678</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1080_01430750_2015_1086678</sourcerecordid><originalsourceid>FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243</originalsourceid><addsrcrecordid>eNp9kM1qwzAQhEVpoSHNIxT0Ak5XsizLt5bQPwj0kp6FLK2oi2IFySH47Ws36bV72WWZGZiPkHsGawYKHoCJEuoK1hxYNb-krNUVWXAmeaG4kNdkMWuKWXRLVjl_wzSigaaGBdntvjDtTaCmN2HMXabRTzfFgHZInaWHeMJEh2T67GPaT3fX587hr6i3IeZjQlpQQ63JSPNwdOMdufEmZFxd9pJ8vjzvNm_F9uP1ffO0LWzJYCjQuhKs4C1KlK1qK65AMNGI1tWOcc8AXam8EaJ26MsaLXMSrbQKsGm4KJekOufaFHNO6PUhdXuTRs1Az3T0Hx0909EXOpPv8ezr-rmTOcUUnB7MGGLyU1PbZV3-H_ED1l1sSA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Thermal analysis of an electric power transformer inside an enclosure - a case study</title><source>Taylor and Francis Science and Technology Collection</source><creator>Abdolzadeh, M. ; Khoshabi, A. ; Mehrabian, M.A.</creator><creatorcontrib>Abdolzadeh, M. ; Khoshabi, A. ; Mehrabian, M.A.</creatorcontrib><description>Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under different operating conditions. The experimental data were collected while the transformer was working in real operating conditions. The 3D numerical analysis was conducted and then verified with the experimental data. The results of this study show that despite lower power loss of the transformer, compared to the conventional transformers which are commonly installed on the overhead power line towers, the enclosure of the transformer has a serious problem of poor ventilation and it causes the transformer to run at higher temperature condition and this consequently decreases the transformer's efficiency. However, this problem can be fixed by implementing some changes in the enclosure's air vents and also by adding a fan on the roof of the enclosure.</description><identifier>ISSN: 0143-0750</identifier><identifier>EISSN: 2162-8246</identifier><identifier>DOI: 10.1080/01430750.2015.1086678</identifier><language>eng</language><publisher>Taylor &amp; Francis</publisher><subject>enclosure ; experimental data ; flow and heat transfer ; numerical ; three-dimensional ; Transformer</subject><ispartof>International journal of ambient energy, 2017-04, Vol.38 (3), p.250-258</ispartof><rights>2015 Informa UK Limited, trading as Taylor &amp; Francis Group 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243</citedby><cites>FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Abdolzadeh, M.</creatorcontrib><creatorcontrib>Khoshabi, A.</creatorcontrib><creatorcontrib>Mehrabian, M.A.</creatorcontrib><title>Thermal analysis of an electric power transformer inside an enclosure - a case study</title><title>International journal of ambient energy</title><description>Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under different operating conditions. The experimental data were collected while the transformer was working in real operating conditions. The 3D numerical analysis was conducted and then verified with the experimental data. The results of this study show that despite lower power loss of the transformer, compared to the conventional transformers which are commonly installed on the overhead power line towers, the enclosure of the transformer has a serious problem of poor ventilation and it causes the transformer to run at higher temperature condition and this consequently decreases the transformer's efficiency. However, this problem can be fixed by implementing some changes in the enclosure's air vents and also by adding a fan on the roof of the enclosure.</description><subject>enclosure</subject><subject>experimental data</subject><subject>flow and heat transfer</subject><subject>numerical</subject><subject>three-dimensional</subject><subject>Transformer</subject><issn>0143-0750</issn><issn>2162-8246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kM1qwzAQhEVpoSHNIxT0Ak5XsizLt5bQPwj0kp6FLK2oi2IFySH47Ws36bV72WWZGZiPkHsGawYKHoCJEuoK1hxYNb-krNUVWXAmeaG4kNdkMWuKWXRLVjl_wzSigaaGBdntvjDtTaCmN2HMXabRTzfFgHZInaWHeMJEh2T67GPaT3fX587hr6i3IeZjQlpQQ63JSPNwdOMdufEmZFxd9pJ8vjzvNm_F9uP1ffO0LWzJYCjQuhKs4C1KlK1qK65AMNGI1tWOcc8AXam8EaJ26MsaLXMSrbQKsGm4KJekOufaFHNO6PUhdXuTRs1Az3T0Hx0909EXOpPv8ezr-rmTOcUUnB7MGGLyU1PbZV3-H_ED1l1sSA</recordid><startdate>20170403</startdate><enddate>20170403</enddate><creator>Abdolzadeh, M.</creator><creator>Khoshabi, A.</creator><creator>Mehrabian, M.A.</creator><general>Taylor &amp; Francis</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20170403</creationdate><title>Thermal analysis of an electric power transformer inside an enclosure - a case study</title><author>Abdolzadeh, M. ; Khoshabi, A. ; Mehrabian, M.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>enclosure</topic><topic>experimental data</topic><topic>flow and heat transfer</topic><topic>numerical</topic><topic>three-dimensional</topic><topic>Transformer</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abdolzadeh, M.</creatorcontrib><creatorcontrib>Khoshabi, A.</creatorcontrib><creatorcontrib>Mehrabian, M.A.</creatorcontrib><collection>CrossRef</collection><jtitle>International journal of ambient energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abdolzadeh, M.</au><au>Khoshabi, A.</au><au>Mehrabian, M.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Thermal analysis of an electric power transformer inside an enclosure - a case study</atitle><jtitle>International journal of ambient energy</jtitle><date>2017-04-03</date><risdate>2017</risdate><volume>38</volume><issue>3</issue><spage>250</spage><epage>258</epage><pages>250-258</pages><issn>0143-0750</issn><eissn>2162-8246</eissn><abstract>Electric transformer inside an enclosure is used in the medium power transmission lines. It reduces the power losses more than other transformers in the transmission lines. In this study, thermal performance of a transformer inside an enclosure was investigated numerically and experimentally under different operating conditions. The experimental data were collected while the transformer was working in real operating conditions. The 3D numerical analysis was conducted and then verified with the experimental data. The results of this study show that despite lower power loss of the transformer, compared to the conventional transformers which are commonly installed on the overhead power line towers, the enclosure of the transformer has a serious problem of poor ventilation and it causes the transformer to run at higher temperature condition and this consequently decreases the transformer's efficiency. However, this problem can be fixed by implementing some changes in the enclosure's air vents and also by adding a fan on the roof of the enclosure.</abstract><pub>Taylor &amp; Francis</pub><doi>10.1080/01430750.2015.1086678</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0143-0750
ispartof International journal of ambient energy, 2017-04, Vol.38 (3), p.250-258
issn 0143-0750
2162-8246
language eng
recordid cdi_crossref_primary_10_1080_01430750_2015_1086678
source Taylor and Francis Science and Technology Collection
subjects enclosure
experimental data
flow and heat transfer
numerical
three-dimensional
Transformer
title Thermal analysis of an electric power transformer inside an enclosure - a case study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A36%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Thermal%20analysis%20of%20an%20electric%20power%20transformer%20inside%20an%20enclosure%20-%20a%20case%20study&rft.jtitle=International%20journal%20of%20ambient%20energy&rft.au=Abdolzadeh,%20M.&rft.date=2017-04-03&rft.volume=38&rft.issue=3&rft.spage=250&rft.epage=258&rft.pages=250-258&rft.issn=0143-0750&rft.eissn=2162-8246&rft_id=info:doi/10.1080/01430750.2015.1086678&rft_dat=%3Ccrossref_infor%3E10_1080_01430750_2015_1086678%3C/crossref_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c310t-ecd30c42be6e6b8b528041494bd7d12f10ed38fa447def37ec1d6ec6c80e99243%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true