Loading…
Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays
To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs. Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after...
Saved in:
Published in: | International journal of radiation biology 2022-07, Vol.98 (7), p.1257-1260 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3 |
---|---|
cites | cdi_FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3 |
container_end_page | 1260 |
container_issue | 7 |
container_start_page | 1257 |
container_title | International journal of radiation biology |
container_volume | 98 |
creator | de Faria, Fernando P. Petroianu, Andy Mota, Luciene G. Fernandes, Simone O. A. Geraldo, Jony M. Nascimento, Clara B. Vital, Katia D. |
description | To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs.
Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after irradiation, and group 3 (n = 6) - irradiated animals studied 48 h after irradiation. The animals were anesthetized and irradiated with a non-fractionated 8 Gy dose in the abdominal region divided into two parallel and opposite fields, 4 Gy was given to the anteroposterior and 4 Gy to the posteroanterior. This high dose of high-energy X-rays causes extensive cell killing, tissue disorganization and break down cell to cell communication. According to the groups, 50 µCi of technetium-phytate were injected into the right internal jugular vein. After 30 minutes, the liver, spleen, kidneys, and lungs were removed. The clot was harvested from the abdominal cavity two minutes after the sectioning of the abdominal aorta and cava vein. The organs and clot were placed into plastic flasks to be weighed and studied for the emission of radioactivity in a gamma radiation detector. The uptake function of each organ was calculated based on the count of gamma rays emitted per minute and normalized with the organ mass, having as a reference the radioactivity count of a standard sample. The arithmetic mean of each organ uptake was calculated and compared among the groups.
After irradiation, the spleen uptake of colloidal radiopharmaceutical was greater, while the hepatic, renal, and pulmonary uptake were lower. The renal uptake decreased slower than the hepatic and pulmonary uptake.
A single high dose of high-energy X-rays enhances the splenic clearance function, while it reduces the hepatic, renal, and pulmonary clearance until 48 h after irradiation, with a rapid deterioration of the hepatic and pulmonary uptake function. |
doi_str_mv | 10.1080/09553002.2022.2020360 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1080_09553002_2022_2020360</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2611652911</sourcerecordid><originalsourceid>FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3</originalsourceid><addsrcrecordid>eNp9kE2P1DAMQCMEYoeFnwDKkQNdnKTNtDfQavmQVuIASJyIPIm7E5QmJWm16r-nZWY5cnEs-Tm2H2MvBVwJaOEtdE2jAOSVBPk3gNLwiO2E0rJSa_Ux221MtUEX7FkpvwA2qn3KLlTdiQ5ku2M_v46Bordv-JFGnLYkU8TAMTo-zmFIEfPCbSDMGC1xt5R-jnbyKXIsJVmPEzl-76cjP_q7Y0WR8t3Cf1QZl_KcPekxFHpxfi_Z9w83364_VbdfPn6-fn9bWaX1VGnXuJrWhWrsXIeNa6yqbe9aaUXX7MWeDr07oIa9Q6C6l6BRoN1LaOtaAqpL9vr075jT75nKZAZfLIWAkdJcjNRC6EZ2Qqxoc0JtTqVk6s2Y_bAeaQSYTa15UGs2teasdu17dR4xHwZy_7oeXK7AuxPgY5_ygPcpB2cmXELK_SbPF6P-P-MPm4WIkA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2611652911</pqid></control><display><type>article</type><title>Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)</source><creator>de Faria, Fernando P. ; Petroianu, Andy ; Mota, Luciene G. ; Fernandes, Simone O. A. ; Geraldo, Jony M. ; Nascimento, Clara B. ; Vital, Katia D.</creator><creatorcontrib>de Faria, Fernando P. ; Petroianu, Andy ; Mota, Luciene G. ; Fernandes, Simone O. A. ; Geraldo, Jony M. ; Nascimento, Clara B. ; Vital, Katia D.</creatorcontrib><description>To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs.
Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after irradiation, and group 3 (n = 6) - irradiated animals studied 48 h after irradiation. The animals were anesthetized and irradiated with a non-fractionated 8 Gy dose in the abdominal region divided into two parallel and opposite fields, 4 Gy was given to the anteroposterior and 4 Gy to the posteroanterior. This high dose of high-energy X-rays causes extensive cell killing, tissue disorganization and break down cell to cell communication. According to the groups, 50 µCi of technetium-phytate were injected into the right internal jugular vein. After 30 minutes, the liver, spleen, kidneys, and lungs were removed. The clot was harvested from the abdominal cavity two minutes after the sectioning of the abdominal aorta and cava vein. The organs and clot were placed into plastic flasks to be weighed and studied for the emission of radioactivity in a gamma radiation detector. The uptake function of each organ was calculated based on the count of gamma rays emitted per minute and normalized with the organ mass, having as a reference the radioactivity count of a standard sample. The arithmetic mean of each organ uptake was calculated and compared among the groups.
After irradiation, the spleen uptake of colloidal radiopharmaceutical was greater, while the hepatic, renal, and pulmonary uptake were lower. The renal uptake decreased slower than the hepatic and pulmonary uptake.
A single high dose of high-energy X-rays enhances the splenic clearance function, while it reduces the hepatic, renal, and pulmonary clearance until 48 h after irradiation, with a rapid deterioration of the hepatic and pulmonary uptake function.</description><identifier>ISSN: 0955-3002</identifier><identifier>EISSN: 1362-3095</identifier><identifier>DOI: 10.1080/09553002.2022.2020360</identifier><identifier>PMID: 34919028</identifier><language>eng</language><publisher>England: Taylor & Francis</publisher><subject>clearance ; irradiation ; kidney ; liver ; lung ; Spleen</subject><ispartof>International journal of radiation biology, 2022-07, Vol.98 (7), p.1257-1260</ispartof><rights>Copyright © 2022 Taylor & Francis Group LLC. 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3</citedby><cites>FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/34919028$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>de Faria, Fernando P.</creatorcontrib><creatorcontrib>Petroianu, Andy</creatorcontrib><creatorcontrib>Mota, Luciene G.</creatorcontrib><creatorcontrib>Fernandes, Simone O. A.</creatorcontrib><creatorcontrib>Geraldo, Jony M.</creatorcontrib><creatorcontrib>Nascimento, Clara B.</creatorcontrib><creatorcontrib>Vital, Katia D.</creatorcontrib><title>Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays</title><title>International journal of radiation biology</title><addtitle>Int J Radiat Biol</addtitle><description>To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs.
Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after irradiation, and group 3 (n = 6) - irradiated animals studied 48 h after irradiation. The animals were anesthetized and irradiated with a non-fractionated 8 Gy dose in the abdominal region divided into two parallel and opposite fields, 4 Gy was given to the anteroposterior and 4 Gy to the posteroanterior. This high dose of high-energy X-rays causes extensive cell killing, tissue disorganization and break down cell to cell communication. According to the groups, 50 µCi of technetium-phytate were injected into the right internal jugular vein. After 30 minutes, the liver, spleen, kidneys, and lungs were removed. The clot was harvested from the abdominal cavity two minutes after the sectioning of the abdominal aorta and cava vein. The organs and clot were placed into plastic flasks to be weighed and studied for the emission of radioactivity in a gamma radiation detector. The uptake function of each organ was calculated based on the count of gamma rays emitted per minute and normalized with the organ mass, having as a reference the radioactivity count of a standard sample. The arithmetic mean of each organ uptake was calculated and compared among the groups.
After irradiation, the spleen uptake of colloidal radiopharmaceutical was greater, while the hepatic, renal, and pulmonary uptake were lower. The renal uptake decreased slower than the hepatic and pulmonary uptake.
A single high dose of high-energy X-rays enhances the splenic clearance function, while it reduces the hepatic, renal, and pulmonary clearance until 48 h after irradiation, with a rapid deterioration of the hepatic and pulmonary uptake function.</description><subject>clearance</subject><subject>irradiation</subject><subject>kidney</subject><subject>liver</subject><subject>lung</subject><subject>Spleen</subject><issn>0955-3002</issn><issn>1362-3095</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kE2P1DAMQCMEYoeFnwDKkQNdnKTNtDfQavmQVuIASJyIPIm7E5QmJWm16r-nZWY5cnEs-Tm2H2MvBVwJaOEtdE2jAOSVBPk3gNLwiO2E0rJSa_Ux221MtUEX7FkpvwA2qn3KLlTdiQ5ku2M_v46Bordv-JFGnLYkU8TAMTo-zmFIEfPCbSDMGC1xt5R-jnbyKXIsJVmPEzl-76cjP_q7Y0WR8t3Cf1QZl_KcPekxFHpxfi_Z9w83364_VbdfPn6-fn9bWaX1VGnXuJrWhWrsXIeNa6yqbe9aaUXX7MWeDr07oIa9Q6C6l6BRoN1LaOtaAqpL9vr075jT75nKZAZfLIWAkdJcjNRC6EZ2Qqxoc0JtTqVk6s2Y_bAeaQSYTa15UGs2teasdu17dR4xHwZy_7oeXK7AuxPgY5_ygPcpB2cmXELK_SbPF6P-P-MPm4WIkA</recordid><startdate>20220703</startdate><enddate>20220703</enddate><creator>de Faria, Fernando P.</creator><creator>Petroianu, Andy</creator><creator>Mota, Luciene G.</creator><creator>Fernandes, Simone O. A.</creator><creator>Geraldo, Jony M.</creator><creator>Nascimento, Clara B.</creator><creator>Vital, Katia D.</creator><general>Taylor & Francis</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20220703</creationdate><title>Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays</title><author>de Faria, Fernando P. ; Petroianu, Andy ; Mota, Luciene G. ; Fernandes, Simone O. A. ; Geraldo, Jony M. ; Nascimento, Clara B. ; Vital, Katia D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>clearance</topic><topic>irradiation</topic><topic>kidney</topic><topic>liver</topic><topic>lung</topic><topic>Spleen</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Faria, Fernando P.</creatorcontrib><creatorcontrib>Petroianu, Andy</creatorcontrib><creatorcontrib>Mota, Luciene G.</creatorcontrib><creatorcontrib>Fernandes, Simone O. A.</creatorcontrib><creatorcontrib>Geraldo, Jony M.</creatorcontrib><creatorcontrib>Nascimento, Clara B.</creatorcontrib><creatorcontrib>Vital, Katia D.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of radiation biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Faria, Fernando P.</au><au>Petroianu, Andy</au><au>Mota, Luciene G.</au><au>Fernandes, Simone O. A.</au><au>Geraldo, Jony M.</au><au>Nascimento, Clara B.</au><au>Vital, Katia D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays</atitle><jtitle>International journal of radiation biology</jtitle><addtitle>Int J Radiat Biol</addtitle><date>2022-07-03</date><risdate>2022</risdate><volume>98</volume><issue>7</issue><spage>1257</spage><epage>1260</epage><pages>1257-1260</pages><issn>0955-3002</issn><eissn>1362-3095</eissn><abstract>To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs.
Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after irradiation, and group 3 (n = 6) - irradiated animals studied 48 h after irradiation. The animals were anesthetized and irradiated with a non-fractionated 8 Gy dose in the abdominal region divided into two parallel and opposite fields, 4 Gy was given to the anteroposterior and 4 Gy to the posteroanterior. This high dose of high-energy X-rays causes extensive cell killing, tissue disorganization and break down cell to cell communication. According to the groups, 50 µCi of technetium-phytate were injected into the right internal jugular vein. After 30 minutes, the liver, spleen, kidneys, and lungs were removed. The clot was harvested from the abdominal cavity two minutes after the sectioning of the abdominal aorta and cava vein. The organs and clot were placed into plastic flasks to be weighed and studied for the emission of radioactivity in a gamma radiation detector. The uptake function of each organ was calculated based on the count of gamma rays emitted per minute and normalized with the organ mass, having as a reference the radioactivity count of a standard sample. The arithmetic mean of each organ uptake was calculated and compared among the groups.
After irradiation, the spleen uptake of colloidal radiopharmaceutical was greater, while the hepatic, renal, and pulmonary uptake were lower. The renal uptake decreased slower than the hepatic and pulmonary uptake.
A single high dose of high-energy X-rays enhances the splenic clearance function, while it reduces the hepatic, renal, and pulmonary clearance until 48 h after irradiation, with a rapid deterioration of the hepatic and pulmonary uptake function.</abstract><cop>England</cop><pub>Taylor & Francis</pub><pmid>34919028</pmid><doi>10.1080/09553002.2022.2020360</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0955-3002 |
ispartof | International journal of radiation biology, 2022-07, Vol.98 (7), p.1257-1260 |
issn | 0955-3002 1362-3095 |
language | eng |
recordid | cdi_crossref_primary_10_1080_09553002_2022_2020360 |
source | Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list) |
subjects | clearance irradiation kidney liver lung Spleen |
title | Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T10%3A05%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Splenic,%20hepatic,%20renal%20and%20pulmonary%20clearance%20dysfunction%20associated%20with%20high-energy%20X-rays&rft.jtitle=International%20journal%20of%20radiation%20biology&rft.au=de%20Faria,%20Fernando%20P.&rft.date=2022-07-03&rft.volume=98&rft.issue=7&rft.spage=1257&rft.epage=1260&rft.pages=1257-1260&rft.issn=0955-3002&rft.eissn=1362-3095&rft_id=info:doi/10.1080/09553002.2022.2020360&rft_dat=%3Cproquest_cross%3E2611652911%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c366t-6d5d4e0284a9d9a5d5c34cfd82c195717ebfdba607da0e4f206a1ac72084420a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2611652911&rft_id=info:pmid/34919028&rfr_iscdi=true |