Loading…

Automated measurement of proprioception following stroke

Background. Proprioception provides feedback which is essential for adequate motor control. Despite having detrimental functional implications, the assessment of proprioception deficits in current clinical practice is mostly qualitative and inadequate for diagnosis and longitudinal monitoring of sub...

Full description

Saved in:
Bibliographic Details
Published in:Disability and rehabilitation 2008, Vol.30 (24), p.1829-1836
Main Authors: Leibowitz, N., Levy, N., Weingarten, S., Grinberg, Y., Karniel, A., Sacher, Y., Serfaty, C., Soroker, N.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background. Proprioception provides feedback which is essential for adequate motor control. Despite having detrimental functional implications, the assessment of proprioception deficits in current clinical practice is mostly qualitative and inadequate for diagnosis and longitudinal monitoring of subtle impairments and their effect on motor function. Purpose. To evaluate a novel quantitative approach to the assessment of proprioception deficits in stroke patients. Method. We designed and implemented an automated protocol where a magnetic motion tracking system and a sensor attached to each of the patient's hands, enables registration of trajectories in 3D coordinates. In this protocol the patient's affected and healthy hands are placed respectively below and above a square board. With vision blocked, the subject's affected hand is passively moved to one of four locations, and then the patient is instructed to actively position the healthy hand directly above his/her perceived location of the affected hand. The positional difference between the two hands is automatically recorded by the system. This procedure is repeated several times and the magnitude and direction of errors are used to quantify the proprioception deficit. The data for this pilot study was collected in a sample of 22 stroke patients and an age-matched group of neurologically intact subjects. Results. Stroke patients had significantly higher mean distance error compared with the control group (average values of 7.9 and 5.3 cm, respectively), and showed higher instability (variance) in repeated performance (average values of the standard deviation of errors 3.4 and 1.8 cm, respectively). Significant correlation was found between the mean distance error and the results of semi-quantitative clinical tests of proprioception. Conclusion. The system provides a reliable quantitative measure of upper limb proprioception, offering considerable advantage over the traditional means applied in the clinic.
ISSN:0963-8288
1464-5165
DOI:10.1080/09638280701640145