Small skin temperature asymmetries are claimed to indicate injuries, but the influence of measurement conditions and technical aspects of image acquisition are concerns for determining temperature asymmetries. This research determines whether distance and camera specifications affect thermal asymmet...

Full description

Saved in:
Bibliographic Details
Published in:Quantitative infrared thermography 2024-03, Vol.21 (2), p.69-81
Main Authors: Machado, Álvaro S., Cañada-Soriano, Mar, Jimenez-Perez, Irene, Gil-Calvo, Marina, Carpes, Felipe Pivetta, Perez-Soriano, Pedro, Priego-Quesada, Jose Ignacio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3
cites cdi_FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3
container_end_page 81
container_issue 2
container_start_page 69
container_title Quantitative infrared thermography
container_volume 21
creator Machado, Álvaro S.
Cañada-Soriano, Mar
Jimenez-Perez, Irene
Gil-Calvo, Marina
Carpes, Felipe Pivetta
Perez-Soriano, Pedro
Priego-Quesada, Jose Ignacio
description Small skin temperature asymmetries are claimed to indicate injuries, but the influence of measurement conditions and technical aspects of image acquisition are concerns for determining temperature asymmetries. This research determines whether distance and camera specifications affect thermal asymmetries detection. We simulated thermal asymmetries filling two glasses with water at different temperatures measured at two distances (0.7 and 1.5 m) using four different infrared cameras (T1020, E60BX, C2 and FLIR ONE). Linear regression verified the similarity between each camera and the T1020 camera (gold standard). The intraclass correlation coefficient assessed the inter-camera reproducibility. Linear regression reported increasing adjustment using mean temperature, with lower values at 1.5 m between the T1020 and FLIR ONE (0.7 m, r = 0.58; 1.5 m, r = 0.34), C2 (0.7 m, r = 0.90; 1.5 m, r = 0.62) and E60BX (0.7 m, r = 0.96; 1.5 m, r = 0.68). Higher inter-camera reproducibility was observed at 0.7 m than 1.5 m. It is preferable to take thermal images with shorter distances and to prioritise cameras with superior hardware characteristics. The portability of FLIR ONE and C2 may be an advantage in studies investigating expected differences greater than 0.05ºC and larger regions of interest.
doi_str_mv 10.1080/17686733.2022.2143227
format article
fullrecord <record><control><sourceid>crossref_infor</sourceid><recordid>TN_cdi_crossref_primary_10_1080_17686733_2022_2143227</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1080_17686733_2022_2143227</sourcerecordid><originalsourceid>FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3</originalsourceid><addsrcrecordid>eNp9kM1qwzAMgM3YYKXrIwz8Aun8kzrxbaP76aCwy3Y2Siy3GXVSbJeRt59Du-t0kUD6hPQRcs_ZkrOaPfBK1aqScimYEEvBSylEdUVmgnNVVLl7TWbTTDEN3ZJFjN8sh5RclWpGTs9dTNC3SKG3tAWPAahDSKeAkXqEmAuPfYoUnMM20bRHajHlsht6Ojia0B8zNREU4ug9ptBl-BS7fke73gUIaCcu-GEX4Lgf78iNg0PExSXPydfry-d6U2w_3t7XT9uilZylAu2q5A2CrVV-SkCjEDm3WufjRYO6tmVZKltp3WjJhNXZCBcWtFO2VdLJOVmd97ZhiDGgM8fQeQij4cxM-syfPjPpMxd9mXs8c_n6IXj4GcLBmgTjYQj5nb7topH_r_gFxvJ5vA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Distance and camera features measurements affect the detection of temperature asymmetries using infrared thermography</title><source>Taylor and Francis Science and Technology Collection</source><creator>Machado, Álvaro S. ; Cañada-Soriano, Mar ; Jimenez-Perez, Irene ; Gil-Calvo, Marina ; Carpes, Felipe Pivetta ; Perez-Soriano, Pedro ; Priego-Quesada, Jose Ignacio</creator><creatorcontrib>Machado, Álvaro S. ; Cañada-Soriano, Mar ; Jimenez-Perez, Irene ; Gil-Calvo, Marina ; Carpes, Felipe Pivetta ; Perez-Soriano, Pedro ; Priego-Quesada, Jose Ignacio</creatorcontrib><description>Small skin temperature asymmetries are claimed to indicate injuries, but the influence of measurement conditions and technical aspects of image acquisition are concerns for determining temperature asymmetries. This research determines whether distance and camera specifications affect thermal asymmetries detection. We simulated thermal asymmetries filling two glasses with water at different temperatures measured at two distances (0.7 and 1.5 m) using four different infrared cameras (T1020, E60BX, C2 and FLIR ONE). Linear regression verified the similarity between each camera and the T1020 camera (gold standard). The intraclass correlation coefficient assessed the inter-camera reproducibility. Linear regression reported increasing adjustment using mean temperature, with lower values at 1.5 m between the T1020 and FLIR ONE (0.7 m, r = 0.58; 1.5 m, r = 0.34), C2 (0.7 m, r = 0.90; 1.5 m, r = 0.62) and E60BX (0.7 m, r = 0.96; 1.5 m, r = 0.68). Higher inter-camera reproducibility was observed at 0.7 m than 1.5 m. It is preferable to take thermal images with shorter distances and to prioritise cameras with superior hardware characteristics. The portability of FLIR ONE and C2 may be an advantage in studies investigating expected differences greater than 0.05ºC and larger regions of interest.</description><identifier>ISSN: 1768-6733</identifier><identifier>EISSN: 2116-7176</identifier><identifier>DOI: 10.1080/17686733.2022.2143227</identifier><language>eng</language><publisher>Taylor &amp; Francis</publisher><subject>Diagnostic imaging ; injury ; medicine ; thermal asymmetries ; thermal imaging ; thermal sensitivity</subject><ispartof>Quantitative infrared thermography, 2024-03, Vol.21 (2), p.69-81</ispartof><rights>2022 Informa UK Limited, trading as Taylor &amp; Francis Group 2022</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3</citedby><cites>FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3</cites><orcidid>0000-0002-9435-2132 ; 0000-0003-4792-1782 ; 0000-0002-9825-3801 ; 0000-0002-0375-1454 ; 0000-0001-7886-2602 ; 0000-0002-4643-2576 ; 0000-0001-8923-4855</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Machado, Álvaro S.</creatorcontrib><creatorcontrib>Cañada-Soriano, Mar</creatorcontrib><creatorcontrib>Jimenez-Perez, Irene</creatorcontrib><creatorcontrib>Gil-Calvo, Marina</creatorcontrib><creatorcontrib>Carpes, Felipe Pivetta</creatorcontrib><creatorcontrib>Perez-Soriano, Pedro</creatorcontrib><creatorcontrib>Priego-Quesada, Jose Ignacio</creatorcontrib><title>Distance and camera features measurements affect the detection of temperature asymmetries using infrared thermography</title><title>Quantitative infrared thermography</title><description>Small skin temperature asymmetries are claimed to indicate injuries, but the influence of measurement conditions and technical aspects of image acquisition are concerns for determining temperature asymmetries. This research determines whether distance and camera specifications affect thermal asymmetries detection. We simulated thermal asymmetries filling two glasses with water at different temperatures measured at two distances (0.7 and 1.5 m) using four different infrared cameras (T1020, E60BX, C2 and FLIR ONE). Linear regression verified the similarity between each camera and the T1020 camera (gold standard). The intraclass correlation coefficient assessed the inter-camera reproducibility. Linear regression reported increasing adjustment using mean temperature, with lower values at 1.5 m between the T1020 and FLIR ONE (0.7 m, r = 0.58; 1.5 m, r = 0.34), C2 (0.7 m, r = 0.90; 1.5 m, r = 0.62) and E60BX (0.7 m, r = 0.96; 1.5 m, r = 0.68). Higher inter-camera reproducibility was observed at 0.7 m than 1.5 m. It is preferable to take thermal images with shorter distances and to prioritise cameras with superior hardware characteristics. The portability of FLIR ONE and C2 may be an advantage in studies investigating expected differences greater than 0.05ºC and larger regions of interest.</description><subject>Diagnostic imaging</subject><subject>injury</subject><subject>medicine</subject><subject>thermal asymmetries</subject><subject>thermal imaging</subject><subject>thermal sensitivity</subject><issn>1768-6733</issn><issn>2116-7176</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kM1qwzAMgM3YYKXrIwz8Aun8kzrxbaP76aCwy3Y2Siy3GXVSbJeRt59Du-t0kUD6hPQRcs_ZkrOaPfBK1aqScimYEEvBSylEdUVmgnNVVLl7TWbTTDEN3ZJFjN8sh5RclWpGTs9dTNC3SKG3tAWPAahDSKeAkXqEmAuPfYoUnMM20bRHajHlsht6Ojia0B8zNREU4ug9ptBl-BS7fke73gUIaCcu-GEX4Lgf78iNg0PExSXPydfry-d6U2w_3t7XT9uilZylAu2q5A2CrVV-SkCjEDm3WufjRYO6tmVZKltp3WjJhNXZCBcWtFO2VdLJOVmd97ZhiDGgM8fQeQij4cxM-syfPjPpMxd9mXs8c_n6IXj4GcLBmgTjYQj5nb7topH_r_gFxvJ5vA</recordid><startdate>20240314</startdate><enddate>20240314</enddate><creator>Machado, Álvaro S.</creator><creator>Cañada-Soriano, Mar</creator><creator>Jimenez-Perez, Irene</creator><creator>Gil-Calvo, Marina</creator><creator>Carpes, Felipe Pivetta</creator><creator>Perez-Soriano, Pedro</creator><creator>Priego-Quesada, Jose Ignacio</creator><general>Taylor &amp; Francis</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-9435-2132</orcidid><orcidid>https://orcid.org/0000-0003-4792-1782</orcidid><orcidid>https://orcid.org/0000-0002-9825-3801</orcidid><orcidid>https://orcid.org/0000-0002-0375-1454</orcidid><orcidid>https://orcid.org/0000-0001-7886-2602</orcidid><orcidid>https://orcid.org/0000-0002-4643-2576</orcidid><orcidid>https://orcid.org/0000-0001-8923-4855</orcidid></search><sort><creationdate>20240314</creationdate><title>Distance and camera features measurements affect the detection of temperature asymmetries using infrared thermography</title><author>Machado, Álvaro S. ; Cañada-Soriano, Mar ; Jimenez-Perez, Irene ; Gil-Calvo, Marina ; Carpes, Felipe Pivetta ; Perez-Soriano, Pedro ; Priego-Quesada, Jose Ignacio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Diagnostic imaging</topic><topic>injury</topic><topic>medicine</topic><topic>thermal asymmetries</topic><topic>thermal imaging</topic><topic>thermal sensitivity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Machado, Álvaro S.</creatorcontrib><creatorcontrib>Cañada-Soriano, Mar</creatorcontrib><creatorcontrib>Jimenez-Perez, Irene</creatorcontrib><creatorcontrib>Gil-Calvo, Marina</creatorcontrib><creatorcontrib>Carpes, Felipe Pivetta</creatorcontrib><creatorcontrib>Perez-Soriano, Pedro</creatorcontrib><creatorcontrib>Priego-Quesada, Jose Ignacio</creatorcontrib><collection>CrossRef</collection><jtitle>Quantitative infrared thermography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Machado, Álvaro S.</au><au>Cañada-Soriano, Mar</au><au>Jimenez-Perez, Irene</au><au>Gil-Calvo, Marina</au><au>Carpes, Felipe Pivetta</au><au>Perez-Soriano, Pedro</au><au>Priego-Quesada, Jose Ignacio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Distance and camera features measurements affect the detection of temperature asymmetries using infrared thermography</atitle><jtitle>Quantitative infrared thermography</jtitle><date>2024-03-14</date><risdate>2024</risdate><volume>21</volume><issue>2</issue><spage>69</spage><epage>81</epage><pages>69-81</pages><issn>1768-6733</issn><eissn>2116-7176</eissn><abstract>Small skin temperature asymmetries are claimed to indicate injuries, but the influence of measurement conditions and technical aspects of image acquisition are concerns for determining temperature asymmetries. This research determines whether distance and camera specifications affect thermal asymmetries detection. We simulated thermal asymmetries filling two glasses with water at different temperatures measured at two distances (0.7 and 1.5 m) using four different infrared cameras (T1020, E60BX, C2 and FLIR ONE). Linear regression verified the similarity between each camera and the T1020 camera (gold standard). The intraclass correlation coefficient assessed the inter-camera reproducibility. Linear regression reported increasing adjustment using mean temperature, with lower values at 1.5 m between the T1020 and FLIR ONE (0.7 m, r = 0.58; 1.5 m, r = 0.34), C2 (0.7 m, r = 0.90; 1.5 m, r = 0.62) and E60BX (0.7 m, r = 0.96; 1.5 m, r = 0.68). Higher inter-camera reproducibility was observed at 0.7 m than 1.5 m. It is preferable to take thermal images with shorter distances and to prioritise cameras with superior hardware characteristics. The portability of FLIR ONE and C2 may be an advantage in studies investigating expected differences greater than 0.05ºC and larger regions of interest.</abstract><pub>Taylor &amp; Francis</pub><doi>10.1080/17686733.2022.2143227</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-9435-2132</orcidid><orcidid>https://orcid.org/0000-0003-4792-1782</orcidid><orcidid>https://orcid.org/0000-0002-9825-3801</orcidid><orcidid>https://orcid.org/0000-0002-0375-1454</orcidid><orcidid>https://orcid.org/0000-0001-7886-2602</orcidid><orcidid>https://orcid.org/0000-0002-4643-2576</orcidid><orcidid>https://orcid.org/0000-0001-8923-4855</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1768-6733
ispartof Quantitative infrared thermography, 2024-03, Vol.21 (2), p.69-81
issn 1768-6733
2116-7176
language eng
recordid cdi_crossref_primary_10_1080_17686733_2022_2143227
source Taylor and Francis Science and Technology Collection
subjects Diagnostic imaging
injury
medicine
thermal asymmetries
thermal imaging
thermal sensitivity
title Distance and camera features measurements affect the detection of temperature asymmetries using infrared thermography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T11%3A22%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Distance%20and%20camera%20features%20measurements%20affect%20the%20detection%20of%20temperature%20asymmetries%20using%20infrared%20thermography&rft.jtitle=Quantitative%20infrared%20thermography&rft.au=Machado,%20%C3%81lvaro%20S.&rft.date=2024-03-14&rft.volume=21&rft.issue=2&rft.spage=69&rft.epage=81&rft.pages=69-81&rft.issn=1768-6733&rft.eissn=2116-7176&rft_id=info:doi/10.1080/17686733.2022.2143227&rft_dat=%3Ccrossref_infor%3E10_1080_17686733_2022_2143227%3C/crossref_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c310t-ed541bead862272ab6ee11d993162be98d4446d799b9302d910812da9f6dc63f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true