Loading…
Development of Acoustic Leak Detection and Localization Methods for Inlet Piping of Fugen Nuclear Power Plant
The development work carried out on Fugen NPP is focused on detection of a small leakage on the reactor's inlet feeder pipes at an early stage by an acoustic leak detection method with usage of high-temperature resistant microphones. Specifically, the leak rate of 0.046 m 3 /h has been chosen a...
Saved in:
Published in: | Journal of nuclear science and technology 2004-02, Vol.41 (2), p.183-195 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The development work carried out on Fugen NPP is focused on detection of a small leakage on the reactor's inlet feeder pipes at an early stage by an acoustic leak detection method with usage of high-temperature resistant microphones. Specifically, the leak rate of 0.046 m
3
/h has been chosen as a target detection capability for this system. A cross-correlation technique has been studied for leak detection under low signal-noise ratios. The study shows that the sound diffusion on piping causes distortion of leak signals that results in their low correlation. A leak-location estimator and multi-channel correlation value, associated with estimated leak position, have been employed to detect such low-correlated leak signals. A method based on cross-correlation of signal spectral components has been proposed to deal with non-stationary leak signals. Joint-Time-Frequency-Analysis has been applied to analyze such signals, whilst a Wavelet decomposition technique has been used to extract their short-term spectral fluctuations. Since the spectral components are less affected by signal distortion, they provide higher correlation value and can be applied for leak detection under lower signal-noise ratios. The possibility of detecting and locating a small leakage by the methods proposed has been demonstrated by a number of simulation tests conducted on the Fugen NPP site. |
---|---|
ISSN: | 0022-3131 1881-1248 |