Loading…
Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine
Microwave assisted head-space solid phase microextraction (MA-HS-SPME) followed by gas chromatography using electron capture detection system (GC-ECD) were developed for determination of chloraacetanilide (butachlor) and chlorpyrifos present in biological samples. The different parameters including...
Saved in:
Published in: | Analytical chemistry letters (Online) 2014-07, Vol.4 (4), p.224-231 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3 |
---|---|
cites | cdi_FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3 |
container_end_page | 231 |
container_issue | 4 |
container_start_page | 224 |
container_title | Analytical chemistry letters (Online) |
container_volume | 4 |
creator | Ghavidel, Fateme Shahtaheri, Seyed Jamaleddin Torabbeigi, Marzieh Rahimi Froushani, Abbas |
description | Microwave assisted head-space solid phase microextraction (MA-HS-SPME) followed by gas chromatography using electron capture detection system (GC-ECD) were developed for determination of chloraacetanilide (butachlor) and chlorpyrifos present in biological samples. The different parameters including microwave irradiation power and microwave irradiation time, which affected on the extraction rate, were optimized. The optimum conditions for extraction of both pesticides were as following: irradiation power of 600 W, microwave irradiation time 10 min, sample volume: 10 ml, sample pH=2 and added salt 10 %. The limit of detection (LOD) for butachlor and chlorpyrifos were 0.0864 and 0.0832 ng/ml, respectively. The optimized methods for both compounds were validated for 6 consequtive days and 6 inter-day using two concentrations of 10 and 100 ng/ml in spiked urine samples that the ranges of obtained recoveries were 91-104 %. |
doi_str_mv | 10.1080/22297928.2014.995704 |
format | article |
fullrecord | <record><control><sourceid>crossref_infor</sourceid><recordid>TN_cdi_crossref_primary_10_1080_22297928_2014_995704</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1080_22297928_2014_995704</sourcerecordid><originalsourceid>FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3</originalsourceid><addsrcrecordid>eNp9UEFOwzAQtBBIVKU_4OAPpKzXSR2fUKmAIhVRqfQcbWJHNUqTyg60-T0JhSunHa1mRjPD2K2AqYAU7hBRK43pFEHEU60TBfEFGyFKiFQi8XLAqKOBc80mIXwAgEQETGYjdnp1hW-O9GX5PAQXWmv40pLhmwMVlm-ayhm-3lGw_IdpT62nonVNzcvG83lNVdfLeFPyh8-Wil3Vf6k2fDGgQ-dd2QS-tqF1hTM2cFfzrXe1vWFXJVXBTn7vmG2fHt8Xy2j19vyymK-iok_dRooSLSzO4pgMmFIhpEJLCUqhiVOCWCe5lLkQOWqDVpkUZpqUtsrmAmIjxyw--_bhQ_C2zA7e7cl3mYBsGDD7GzAbBszOA_ay-7PM1X3PPR0bX5mspa5vVXqqCxcy-a_DN-hqd-Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine</title><source>Taylor and Francis Science and Technology Collection</source><creator>Ghavidel, Fateme ; Shahtaheri, Seyed Jamaleddin ; Torabbeigi, Marzieh ; Rahimi Froushani, Abbas</creator><creatorcontrib>Ghavidel, Fateme ; Shahtaheri, Seyed Jamaleddin ; Torabbeigi, Marzieh ; Rahimi Froushani, Abbas</creatorcontrib><description>Microwave assisted head-space solid phase microextraction (MA-HS-SPME) followed by gas chromatography using electron capture detection system (GC-ECD) were developed for determination of chloraacetanilide (butachlor) and chlorpyrifos present in biological samples. The different parameters including microwave irradiation power and microwave irradiation time, which affected on the extraction rate, were optimized. The optimum conditions for extraction of both pesticides were as following: irradiation power of 600 W, microwave irradiation time 10 min, sample volume: 10 ml, sample pH=2 and added salt 10 %. The limit of detection (LOD) for butachlor and chlorpyrifos were 0.0864 and 0.0832 ng/ml, respectively. The optimized methods for both compounds were validated for 6 consequtive days and 6 inter-day using two concentrations of 10 and 100 ng/ml in spiked urine samples that the ranges of obtained recoveries were 91-104 %.</description><identifier>ISSN: 2229-7928</identifier><identifier>EISSN: 2230-7532</identifier><identifier>DOI: 10.1080/22297928.2014.995704</identifier><language>eng</language><publisher>Taylor & Francis</publisher><subject>biological samples ; butachlor ; chlorpyrifos ; GC-ECD ; MA-HS-SPME</subject><ispartof>Analytical chemistry letters (Online), 2014-07, Vol.4 (4), p.224-231</ispartof><rights>2014, Har Krishan Bhalla & Sons 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3</citedby><cites>FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Ghavidel, Fateme</creatorcontrib><creatorcontrib>Shahtaheri, Seyed Jamaleddin</creatorcontrib><creatorcontrib>Torabbeigi, Marzieh</creatorcontrib><creatorcontrib>Rahimi Froushani, Abbas</creatorcontrib><title>Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine</title><title>Analytical chemistry letters (Online)</title><description>Microwave assisted head-space solid phase microextraction (MA-HS-SPME) followed by gas chromatography using electron capture detection system (GC-ECD) were developed for determination of chloraacetanilide (butachlor) and chlorpyrifos present in biological samples. The different parameters including microwave irradiation power and microwave irradiation time, which affected on the extraction rate, were optimized. The optimum conditions for extraction of both pesticides were as following: irradiation power of 600 W, microwave irradiation time 10 min, sample volume: 10 ml, sample pH=2 and added salt 10 %. The limit of detection (LOD) for butachlor and chlorpyrifos were 0.0864 and 0.0832 ng/ml, respectively. The optimized methods for both compounds were validated for 6 consequtive days and 6 inter-day using two concentrations of 10 and 100 ng/ml in spiked urine samples that the ranges of obtained recoveries were 91-104 %.</description><subject>biological samples</subject><subject>butachlor</subject><subject>chlorpyrifos</subject><subject>GC-ECD</subject><subject>MA-HS-SPME</subject><issn>2229-7928</issn><issn>2230-7532</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp9UEFOwzAQtBBIVKU_4OAPpKzXSR2fUKmAIhVRqfQcbWJHNUqTyg60-T0JhSunHa1mRjPD2K2AqYAU7hBRK43pFEHEU60TBfEFGyFKiFQi8XLAqKOBc80mIXwAgEQETGYjdnp1hW-O9GX5PAQXWmv40pLhmwMVlm-ayhm-3lGw_IdpT62nonVNzcvG83lNVdfLeFPyh8-Wil3Vf6k2fDGgQ-dd2QS-tqF1hTM2cFfzrXe1vWFXJVXBTn7vmG2fHt8Xy2j19vyymK-iok_dRooSLSzO4pgMmFIhpEJLCUqhiVOCWCe5lLkQOWqDVpkUZpqUtsrmAmIjxyw--_bhQ_C2zA7e7cl3mYBsGDD7GzAbBszOA_ay-7PM1X3PPR0bX5mspa5vVXqqCxcy-a_DN-hqd-Y</recordid><startdate>20140704</startdate><enddate>20140704</enddate><creator>Ghavidel, Fateme</creator><creator>Shahtaheri, Seyed Jamaleddin</creator><creator>Torabbeigi, Marzieh</creator><creator>Rahimi Froushani, Abbas</creator><general>Taylor & Francis</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20140704</creationdate><title>Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine</title><author>Ghavidel, Fateme ; Shahtaheri, Seyed Jamaleddin ; Torabbeigi, Marzieh ; Rahimi Froushani, Abbas</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>biological samples</topic><topic>butachlor</topic><topic>chlorpyrifos</topic><topic>GC-ECD</topic><topic>MA-HS-SPME</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ghavidel, Fateme</creatorcontrib><creatorcontrib>Shahtaheri, Seyed Jamaleddin</creatorcontrib><creatorcontrib>Torabbeigi, Marzieh</creatorcontrib><creatorcontrib>Rahimi Froushani, Abbas</creatorcontrib><collection>CrossRef</collection><jtitle>Analytical chemistry letters (Online)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ghavidel, Fateme</au><au>Shahtaheri, Seyed Jamaleddin</au><au>Torabbeigi, Marzieh</au><au>Rahimi Froushani, Abbas</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine</atitle><jtitle>Analytical chemistry letters (Online)</jtitle><date>2014-07-04</date><risdate>2014</risdate><volume>4</volume><issue>4</issue><spage>224</spage><epage>231</epage><pages>224-231</pages><issn>2229-7928</issn><eissn>2230-7532</eissn><abstract>Microwave assisted head-space solid phase microextraction (MA-HS-SPME) followed by gas chromatography using electron capture detection system (GC-ECD) were developed for determination of chloraacetanilide (butachlor) and chlorpyrifos present in biological samples. The different parameters including microwave irradiation power and microwave irradiation time, which affected on the extraction rate, were optimized. The optimum conditions for extraction of both pesticides were as following: irradiation power of 600 W, microwave irradiation time 10 min, sample volume: 10 ml, sample pH=2 and added salt 10 %. The limit of detection (LOD) for butachlor and chlorpyrifos were 0.0864 and 0.0832 ng/ml, respectively. The optimized methods for both compounds were validated for 6 consequtive days and 6 inter-day using two concentrations of 10 and 100 ng/ml in spiked urine samples that the ranges of obtained recoveries were 91-104 %.</abstract><pub>Taylor & Francis</pub><doi>10.1080/22297928.2014.995704</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2229-7928 |
ispartof | Analytical chemistry letters (Online), 2014-07, Vol.4 (4), p.224-231 |
issn | 2229-7928 2230-7532 |
language | eng |
recordid | cdi_crossref_primary_10_1080_22297928_2014_995704 |
source | Taylor and Francis Science and Technology Collection |
subjects | biological samples butachlor chlorpyrifos GC-ECD MA-HS-SPME |
title | Microwave Assisted Head Space Solid Phase Microextraction for Analysis of Butachlor and Chlorpyrifos Pesticides in Urine |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T03%3A10%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microwave%20Assisted%20Head%20Space%20Solid%20Phase%20Microextraction%20for%20Analysis%20of%20Butachlor%20and%20Chlorpyrifos%20Pesticides%20in%20Urine&rft.jtitle=Analytical%20chemistry%20letters%20(Online)&rft.au=Ghavidel,%20Fateme&rft.date=2014-07-04&rft.volume=4&rft.issue=4&rft.spage=224&rft.epage=231&rft.pages=224-231&rft.issn=2229-7928&rft.eissn=2230-7532&rft_id=info:doi/10.1080/22297928.2014.995704&rft_dat=%3Ccrossref_infor%3E10_1080_22297928_2014_995704%3C/crossref_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c222t-7a591e2644ad0df720819330772d48a0495b33b11b29d2e7d8069a79e7eb104d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |