Current Sharing Temperature Test and Simulation with GANDALF Code for ITER PF2 Conductor Sample

Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the current sharing temperature. Under the typical operational conditions of a current of 4...

Full description

Saved in:
Bibliographic Details
Published in:Plasma science & technology 2011-10, Vol.13 (5), p.627-630
Main Author: 李少磊 武玉 刘勃 翁佩德
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Cable-in-conduit conductor (CICC) conductor sample of the PF2 coil for ITER was tested in the SULTAN facility. According to the test results, the CICC conductor sample exhibited a stable performance regarding the current sharing temperature. Under the typical operational conditions of a current of 45 kA, a magnetic field of 4 T and a temperature of 5 K for PF2, the test result for the conductor current sharing temperature is 6.71 K, with a temperature margin of 1.71 K. For a comparison thermal-hydraulic analysis of the PF2 conductor was carried out using GANDALF code in a 1-D model, and the result is consistent with the test one.