Loading…

A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations

A Phase-contrast imaging (PCI) diagnostic provides measurements of line-integrated electron density fluctuations. Localisation along the laser beam path can be achieved with a spatial filter that selects the wave-vector directions of the fluctuations contributing to the PCI measurement and is a key...

Full description

Saved in:
Bibliographic Details
Published in:Plasma physics and controlled fusion 2023-02, Vol.65 (2), p.25005
Main Authors: Iantchenko, A, Coda, S, Brunner, S, Merlo, G, Ball, J, Margairaz, F
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3
cites cdi_FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3
container_end_page
container_issue 2
container_start_page 25005
container_title Plasma physics and controlled fusion
container_volume 65
creator Iantchenko, A
Coda, S
Brunner, S
Merlo, G
Ball, J
Margairaz, F
description A Phase-contrast imaging (PCI) diagnostic provides measurements of line-integrated electron density fluctuations. Localisation along the laser beam path can be achieved with a spatial filter that selects the wave-vector directions of the fluctuations contributing to the PCI measurement and is a key feature of the PCI diagnostic installed on the TCV tokamak and also of a similar system planned for JT-60SA. We have developed a synthetic diagnostic that models measurements from PCI taking into account the effect of such a spatial filter. The synthetic tool is based on the principle of integrating over selected diagnostic volumes the electron density fluctuations generated by turbulence simulations, and applying an appropriate spatial filter in wave-vector space. We demonstrate the effect of the filter for a positive and a negative triangularity TCV discharge, and illustrate the potential of the synthetic diagnostic for better understanding the corresponding experimental results. We consider different types of filters and make first-principle estimates of the localisation of the measurement. Finally, using gyrokinetic simulations that include electromagnetic effects, collisions and four kinetic species, we make first predictions of the characteristics of the measurements using the planned set-up of PCI on JT-60SA.
doi_str_mv 10.1088/1361-6587/aca4f7
format article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1088_1361_6587_aca4f7</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ppcfaca4f7</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3</originalsourceid><addsrcrecordid>eNp1kMtOwzAQRS0EEqWwZ-kPwNSPNE6WVcVLqsQG1mac2qlLake2K9S_JyGIHauRRudezRyEbhm9Z7SqFkyUjJTLSi6ggcLKMzT7W52jGZUFI0KI5SW6SmlPKWMVL2foY4XTyeedya7B_Q6SIU3wOULK2B2gdb7FWwetD2kkvlze4dRDdtBh67ps4kjYEHF7iuHT-Z-i5A7HboCCT9fowkKXzM3vnKP3x4e39TPZvD69rFcb0gjOM-FAjdwKrrkAa7StlkBrDZbqQhaFFkxQC7VsKlYbybWRpjZaU8tqy7fWgJgjOvU2MaQUjVV9HB6IJ8WoGg2pUYcadajJ0BC5myIu9GofjtEPB_6PfwPhuWu-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Iantchenko, A ; Coda, S ; Brunner, S ; Merlo, G ; Ball, J ; Margairaz, F</creator><creatorcontrib>Iantchenko, A ; Coda, S ; Brunner, S ; Merlo, G ; Ball, J ; Margairaz, F</creatorcontrib><description>A Phase-contrast imaging (PCI) diagnostic provides measurements of line-integrated electron density fluctuations. Localisation along the laser beam path can be achieved with a spatial filter that selects the wave-vector directions of the fluctuations contributing to the PCI measurement and is a key feature of the PCI diagnostic installed on the TCV tokamak and also of a similar system planned for JT-60SA. We have developed a synthetic diagnostic that models measurements from PCI taking into account the effect of such a spatial filter. The synthetic tool is based on the principle of integrating over selected diagnostic volumes the electron density fluctuations generated by turbulence simulations, and applying an appropriate spatial filter in wave-vector space. We demonstrate the effect of the filter for a positive and a negative triangularity TCV discharge, and illustrate the potential of the synthetic diagnostic for better understanding the corresponding experimental results. We consider different types of filters and make first-principle estimates of the localisation of the measurement. Finally, using gyrokinetic simulations that include electromagnetic effects, collisions and four kinetic species, we make first predictions of the characteristics of the measurements using the planned set-up of PCI on JT-60SA.</description><identifier>ISSN: 0741-3335</identifier><identifier>EISSN: 1361-6587</identifier><identifier>DOI: 10.1088/1361-6587/aca4f7</identifier><identifier>CODEN: PLPHBZ</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>GAM ; gyrokinetic simulations ; phase-contrast imaging ; synthetic diagnostic ; TCV ; turbulence</subject><ispartof>Plasma physics and controlled fusion, 2023-02, Vol.65 (2), p.25005</ispartof><rights>2022 The Author(s). Published by IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3</citedby><cites>FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3</cites><orcidid>0000-0001-7588-7476 ; 0000-0003-4786-1791 ; 0000-0003-4877-1456 ; 0000-0002-4462-6350 ; 0000-0002-8010-4971</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Iantchenko, A</creatorcontrib><creatorcontrib>Coda, S</creatorcontrib><creatorcontrib>Brunner, S</creatorcontrib><creatorcontrib>Merlo, G</creatorcontrib><creatorcontrib>Ball, J</creatorcontrib><creatorcontrib>Margairaz, F</creatorcontrib><title>A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations</title><title>Plasma physics and controlled fusion</title><addtitle>PPCF</addtitle><addtitle>Plasma Phys. Control. Fusion</addtitle><description>A Phase-contrast imaging (PCI) diagnostic provides measurements of line-integrated electron density fluctuations. Localisation along the laser beam path can be achieved with a spatial filter that selects the wave-vector directions of the fluctuations contributing to the PCI measurement and is a key feature of the PCI diagnostic installed on the TCV tokamak and also of a similar system planned for JT-60SA. We have developed a synthetic diagnostic that models measurements from PCI taking into account the effect of such a spatial filter. The synthetic tool is based on the principle of integrating over selected diagnostic volumes the electron density fluctuations generated by turbulence simulations, and applying an appropriate spatial filter in wave-vector space. We demonstrate the effect of the filter for a positive and a negative triangularity TCV discharge, and illustrate the potential of the synthetic diagnostic for better understanding the corresponding experimental results. We consider different types of filters and make first-principle estimates of the localisation of the measurement. Finally, using gyrokinetic simulations that include electromagnetic effects, collisions and four kinetic species, we make first predictions of the characteristics of the measurements using the planned set-up of PCI on JT-60SA.</description><subject>GAM</subject><subject>gyrokinetic simulations</subject><subject>phase-contrast imaging</subject><subject>synthetic diagnostic</subject><subject>TCV</subject><subject>turbulence</subject><issn>0741-3335</issn><issn>1361-6587</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp1kMtOwzAQRS0EEqWwZ-kPwNSPNE6WVcVLqsQG1mac2qlLake2K9S_JyGIHauRRudezRyEbhm9Z7SqFkyUjJTLSi6ggcLKMzT7W52jGZUFI0KI5SW6SmlPKWMVL2foY4XTyeedya7B_Q6SIU3wOULK2B2gdb7FWwetD2kkvlze4dRDdtBh67ps4kjYEHF7iuHT-Z-i5A7HboCCT9fowkKXzM3vnKP3x4e39TPZvD69rFcb0gjOM-FAjdwKrrkAa7StlkBrDZbqQhaFFkxQC7VsKlYbybWRpjZaU8tqy7fWgJgjOvU2MaQUjVV9HB6IJ8WoGg2pUYcadajJ0BC5myIu9GofjtEPB_6PfwPhuWu-</recordid><startdate>20230201</startdate><enddate>20230201</enddate><creator>Iantchenko, A</creator><creator>Coda, S</creator><creator>Brunner, S</creator><creator>Merlo, G</creator><creator>Ball, J</creator><creator>Margairaz, F</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-7588-7476</orcidid><orcidid>https://orcid.org/0000-0003-4786-1791</orcidid><orcidid>https://orcid.org/0000-0003-4877-1456</orcidid><orcidid>https://orcid.org/0000-0002-4462-6350</orcidid><orcidid>https://orcid.org/0000-0002-8010-4971</orcidid></search><sort><creationdate>20230201</creationdate><title>A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations</title><author>Iantchenko, A ; Coda, S ; Brunner, S ; Merlo, G ; Ball, J ; Margairaz, F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>GAM</topic><topic>gyrokinetic simulations</topic><topic>phase-contrast imaging</topic><topic>synthetic diagnostic</topic><topic>TCV</topic><topic>turbulence</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Iantchenko, A</creatorcontrib><creatorcontrib>Coda, S</creatorcontrib><creatorcontrib>Brunner, S</creatorcontrib><creatorcontrib>Merlo, G</creatorcontrib><creatorcontrib>Ball, J</creatorcontrib><creatorcontrib>Margairaz, F</creatorcontrib><collection>IOP Publishing (Open access)</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><jtitle>Plasma physics and controlled fusion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Iantchenko, A</au><au>Coda, S</au><au>Brunner, S</au><au>Merlo, G</au><au>Ball, J</au><au>Margairaz, F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations</atitle><jtitle>Plasma physics and controlled fusion</jtitle><stitle>PPCF</stitle><addtitle>Plasma Phys. Control. Fusion</addtitle><date>2023-02-01</date><risdate>2023</risdate><volume>65</volume><issue>2</issue><spage>25005</spage><pages>25005-</pages><issn>0741-3335</issn><eissn>1361-6587</eissn><coden>PLPHBZ</coden><abstract>A Phase-contrast imaging (PCI) diagnostic provides measurements of line-integrated electron density fluctuations. Localisation along the laser beam path can be achieved with a spatial filter that selects the wave-vector directions of the fluctuations contributing to the PCI measurement and is a key feature of the PCI diagnostic installed on the TCV tokamak and also of a similar system planned for JT-60SA. We have developed a synthetic diagnostic that models measurements from PCI taking into account the effect of such a spatial filter. The synthetic tool is based on the principle of integrating over selected diagnostic volumes the electron density fluctuations generated by turbulence simulations, and applying an appropriate spatial filter in wave-vector space. We demonstrate the effect of the filter for a positive and a negative triangularity TCV discharge, and illustrate the potential of the synthetic diagnostic for better understanding the corresponding experimental results. We consider different types of filters and make first-principle estimates of the localisation of the measurement. Finally, using gyrokinetic simulations that include electromagnetic effects, collisions and four kinetic species, we make first predictions of the characteristics of the measurements using the planned set-up of PCI on JT-60SA.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6587/aca4f7</doi><tpages>29</tpages><orcidid>https://orcid.org/0000-0001-7588-7476</orcidid><orcidid>https://orcid.org/0000-0003-4786-1791</orcidid><orcidid>https://orcid.org/0000-0003-4877-1456</orcidid><orcidid>https://orcid.org/0000-0002-4462-6350</orcidid><orcidid>https://orcid.org/0000-0002-8010-4971</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0741-3335
ispartof Plasma physics and controlled fusion, 2023-02, Vol.65 (2), p.25005
issn 0741-3335
1361-6587
language eng
recordid cdi_crossref_primary_10_1088_1361_6587_aca4f7
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects GAM
gyrokinetic simulations
phase-contrast imaging
synthetic diagnostic
TCV
turbulence
title A synthetic phase-contrast imaging diagnostic with spatial filtering for gyrokinetic simulations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T14%3A29%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20synthetic%20phase-contrast%20imaging%20diagnostic%20with%20spatial%20filtering%20for%20gyrokinetic%20simulations&rft.jtitle=Plasma%20physics%20and%20controlled%20fusion&rft.au=Iantchenko,%20A&rft.date=2023-02-01&rft.volume=65&rft.issue=2&rft.spage=25005&rft.pages=25005-&rft.issn=0741-3335&rft.eissn=1361-6587&rft.coden=PLPHBZ&rft_id=info:doi/10.1088/1361-6587/aca4f7&rft_dat=%3Ciop_cross%3Eppcfaca4f7%3C/iop_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c322t-2a0e7d32b23afebf85a09baf0b4744b3130fa97c819e72be7e9ebb0f19f2dfea3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true