Loading…

Intensity crack zones of reinforced concrete beam under monotonic loading

This paper presents the intensity crack zones of reinforced concrete (RC) beam under monotonic loading in conjunction with acoustic emission (AE) monitoring. Five RC beam size 200 mm x 300 mm x 1500 mm were prepared and tested. Due to similar pattern in term of the crack pattern and the analysis, on...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2019-11, Vol.1349 (1), p.12086
Main Authors: Mat Saliah, S N, Nor, N Md, Kamaruzzaman, K N, Mohd Mesron, M A, Abd Rahman, N
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper presents the intensity crack zones of reinforced concrete (RC) beam under monotonic loading in conjunction with acoustic emission (AE) monitoring. Five RC beam size 200 mm x 300 mm x 1500 mm were prepared and tested. Due to similar pattern in term of the crack pattern and the analysis, only one beam was presented in this paper. The intensity crack zones were performed by mean of historic and severity indices at sensor 6 (CH6) and sensor 7 (CH7). The plot in the intensity crack zone was based on the crack mode performed during testing. As a result, the progression of the crack was well-matched with the plots in the intensity crack zones. In a nutshell, the data obtained from the AE signal and analyse using intensity analysis, it can be used to classify damage in the RC beam.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/1349/1/012086