Rapid gas temperature measurement device for gas turbine engines with detection of pre-surge phenomena
A differential system for measurement of gas temperature in gas turbine engines (GTE) using acoustic multi-vibrators was presented. Application of acoustic multi-vibrators improves the response time by three orders of magnitude compared to thermocouples. Combined use with a gas flow meter and a vibr...
Saved in:
Published in: | Journal of physics. Conference series 2021-05, Vol.1891 (1), p.12048 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A differential system for measurement of gas temperature in gas turbine engines (GTE) using acoustic multi-vibrators was presented. Application of acoustic multi-vibrators improves the response time by three orders of magnitude compared to thermocouples. Combined use with a gas flow meter and a vibration sensor makes it possible to measure the low-frequency component of acoustic vibrations of flowing gases in a GTE’s combustion chamber. As an example, a calculation to determine the resonance frequency of a combustion chamber of a GTE was given. |
---|---|