Loading…

Experimental Investigation of Air Circulation Using Duct System in a Non-AC Bus Coach

Public transport is the life line in many of the developing and under developed countries for the safe conveyance, i.e. also consider as economical. The major limitation in public transport (non-AC busses) Air Condition, is the lack of proper air circulation leading to suffocation and vomiting. The...

Full description

Saved in:
Bibliographic Details
Published in:IOP conference series. Materials Science and Engineering 2021-02, Vol.1065 (1), p.12006
Main Authors: Niranjana, SJ, Kubsad, Shivalingappa S, Nagaraj, Y, Manjunath, S, Shivakumar, S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Public transport is the life line in many of the developing and under developed countries for the safe conveyance, i.e. also consider as economical. The major limitation in public transport (non-AC busses) Air Condition, is the lack of proper air circulation leading to suffocation and vomiting. The present research work emphasis on design and analysis of air flow duct system (non AC Busses) to increase the level of comfortance of the passengers, tools like solidworks software 2016 is used for 3D drawing, Hypermesh software 13.0 is for the discretization and ANSYS Fluent software 16.0 for the Computational Fluid Dynamic (CFD) analysis, from the experimental the airflow is found to be 10 m/s, and from the numerical analysis the airflow is found to be 9.8 m/s, by comparing the experimental and numerical results a negligible deviation of 2% is observed and it is within the limit.
ISSN:1757-8981
1757-899X
DOI:10.1088/1757-899X/1065/1/012006