Loading…
Experimental and theoretical assessment of power frequency electric field individual protective means
Electromagnetic field levels at workplaces may exceed permissible limit values. In this case the individual protective means use obligatory. There are presented the date of typical samples of conductive suits (under work in power frequency electric field) testing by simulation and in experiment. Ind...
Saved in:
Published in: | IOP conference series. Materials Science and Engineering 2019-03, Vol.487 (1), p.12031 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Electromagnetic field levels at workplaces may exceed permissible limit values. In this case the individual protective means use obligatory. There are presented the date of typical samples of conductive suits (under work in power frequency electric field) testing by simulation and in experiment. Individual protective means screening factors were changed from 42.26 to 52.43 dB. The averaged electric field level inside of conductive suit was 220 mV/m in case of simulation. The induced electric fields in human body tissues with conductive suit were 0.003-0.150 V/m. The results show that conductive suit use allows reducing the induced electric filed levels and ensures worker safety. |
---|---|
ISSN: | 1757-8981 1757-899X 1757-899X |
DOI: | 10.1088/1757-899X/487/1/012031 |