Experimental and theoretical assessment of power frequency electric field individual protective means

Electromagnetic field levels at workplaces may exceed permissible limit values. In this case the individual protective means use obligatory. There are presented the date of typical samples of conductive suits (under work in power frequency electric field) testing by simulation and in experiment. Ind...

Full description

Saved in:
Bibliographic Details
Published in:IOP conference series. Materials Science and Engineering 2019-03, Vol.487 (1), p.12031
Main Authors: Perov, S Yu, Belaya, O V, Khrennikova, T A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Electromagnetic field levels at workplaces may exceed permissible limit values. In this case the individual protective means use obligatory. There are presented the date of typical samples of conductive suits (under work in power frequency electric field) testing by simulation and in experiment. Individual protective means screening factors were changed from 42.26 to 52.43 dB. The averaged electric field level inside of conductive suit was 220 mV/m in case of simulation. The induced electric fields in human body tissues with conductive suit were 0.003-0.150 V/m. The results show that conductive suit use allows reducing the induced electric filed levels and ensures worker safety.