Loading…
Pen Dosemeters Electronic Read Unit
A pen dosemeter read unit has been developed. The low cost reader makes use of an optic RAM, interfaced to a microcomputer, as a digital, solid-state image sensor. Images of the fibre with the reticle of the dosemeter are shown and automatically read.
Saved in:
Published in: | Radiation protection dosimetry 1985-04, Vol.11 (2), p.131-132 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 132 |
container_issue | 2 |
container_start_page | 131 |
container_title | Radiation protection dosimetry |
container_volume | 11 |
creator | Castellano, A. Staderini, E.M. |
description | A pen dosemeter read unit has been developed. The low cost reader makes use of an optic RAM, interfaced to a microcomputer, as a digital, solid-state image sensor. Images of the fibre with the reticle of the dosemeter are shown and automatically read. |
doi_str_mv | 10.1093/oxfordjournals.rpd.a079457 |
format | article |
fullrecord | <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1093_oxfordjournals_rpd_a079457</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_HXZ_XCCHRKZ9_9</sourcerecordid><originalsourceid>FETCH-LOGICAL-c186t-64aefe1783ed2edf96b9c357c51627b29428fc2ca31218238e32895412348f23</originalsourceid><addsrcrecordid>eNpVj01LAzEURYMoWD_-w6BupyYvySRxJ2O1YkEpFUo3Ic28wNR2piQj1H_vSEvB1Vvcew_vEHLD6JBRw-_bXWhjtWq_Y-PWaRi31dBRZYRUJ2TAlICcC1qckgFlQuRaAD0nFymtKAVlpBiQ2w9ssqc24QY7jCkbrdF3sW1qn03RVdlnU3dX5Cz0dLw-3Esyex7NynE-eX95LR8nuWe66PJCOAzIlOZYAVbBFEvjuVResgLUEowAHTx4xxkwDVwjB90_wYALHYBfkoc91sc2pYjBbmO9cfHHMmr_bO1_W9vb2oNtP77bj7cuebcO0TW-TkeCllQqJfpavq_VqcPdMXbxyxaKK2nH84Wdl-V4-rYw1vBfSc9pnw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Pen Dosemeters Electronic Read Unit</title><source>Oxford University Press Archive</source><creator>Castellano, A. ; Staderini, E.M.</creator><creatorcontrib>Castellano, A. ; Staderini, E.M.</creatorcontrib><description>A pen dosemeter read unit has been developed. The low cost reader makes use of an optic RAM, interfaced to a microcomputer, as a digital, solid-state image sensor. Images of the fibre with the reticle of the dosemeter are shown and automatically read.</description><identifier>ISSN: 0144-8420</identifier><identifier>ISSN: 1742-3406</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/oxfordjournals.rpd.a079457</identifier><identifier>CODEN: RPDODE</identifier><language>eng</language><publisher>Oxford: Oxford University Press</publisher><subject>Applied radiobiology (equipment, dosimetry...) ; Biological and medical sciences ; Biological effects of radiation ; Fundamental and applied biological sciences. Psychology ; Tissues, organs and organisms biophysics</subject><ispartof>Radiation protection dosimetry, 1985-04, Vol.11 (2), p.131-132</ispartof><rights>1986 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=8505774$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Castellano, A.</creatorcontrib><creatorcontrib>Staderini, E.M.</creatorcontrib><title>Pen Dosemeters Electronic Read Unit</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>A pen dosemeter read unit has been developed. The low cost reader makes use of an optic RAM, interfaced to a microcomputer, as a digital, solid-state image sensor. Images of the fibre with the reticle of the dosemeter are shown and automatically read.</description><subject>Applied radiobiology (equipment, dosimetry...)</subject><subject>Biological and medical sciences</subject><subject>Biological effects of radiation</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Tissues, organs and organisms biophysics</subject><issn>0144-8420</issn><issn>1742-3406</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1985</creationdate><recordtype>article</recordtype><recordid>eNpVj01LAzEURYMoWD_-w6BupyYvySRxJ2O1YkEpFUo3Ic28wNR2piQj1H_vSEvB1Vvcew_vEHLD6JBRw-_bXWhjtWq_Y-PWaRi31dBRZYRUJ2TAlICcC1qckgFlQuRaAD0nFymtKAVlpBiQ2w9ssqc24QY7jCkbrdF3sW1qn03RVdlnU3dX5Cz0dLw-3Esyex7NynE-eX95LR8nuWe66PJCOAzIlOZYAVbBFEvjuVResgLUEowAHTx4xxkwDVwjB90_wYALHYBfkoc91sc2pYjBbmO9cfHHMmr_bO1_W9vb2oNtP77bj7cuebcO0TW-TkeCllQqJfpavq_VqcPdMXbxyxaKK2nH84Wdl-V4-rYw1vBfSc9pnw</recordid><startdate>19850401</startdate><enddate>19850401</enddate><creator>Castellano, A.</creator><creator>Staderini, E.M.</creator><general>Oxford University Press</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19850401</creationdate><title>Pen Dosemeters Electronic Read Unit</title><author>Castellano, A. ; Staderini, E.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c186t-64aefe1783ed2edf96b9c357c51627b29428fc2ca31218238e32895412348f23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1985</creationdate><topic>Applied radiobiology (equipment, dosimetry...)</topic><topic>Biological and medical sciences</topic><topic>Biological effects of radiation</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Tissues, organs and organisms biophysics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Castellano, A.</creatorcontrib><creatorcontrib>Staderini, E.M.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Castellano, A.</au><au>Staderini, E.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pen Dosemeters Electronic Read Unit</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>1985-04-01</date><risdate>1985</risdate><volume>11</volume><issue>2</issue><spage>131</spage><epage>132</epage><pages>131-132</pages><issn>0144-8420</issn><issn>1742-3406</issn><eissn>1742-3406</eissn><coden>RPDODE</coden><abstract>A pen dosemeter read unit has been developed. The low cost reader makes use of an optic RAM, interfaced to a microcomputer, as a digital, solid-state image sensor. Images of the fibre with the reticle of the dosemeter are shown and automatically read.</abstract><cop>Oxford</cop><pub>Oxford University Press</pub><doi>10.1093/oxfordjournals.rpd.a079457</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0144-8420 |
ispartof | Radiation protection dosimetry, 1985-04, Vol.11 (2), p.131-132 |
issn | 0144-8420 1742-3406 1742-3406 |
language | eng |
recordid | cdi_crossref_primary_10_1093_oxfordjournals_rpd_a079457 |
source | Oxford University Press Archive |
subjects | Applied radiobiology (equipment, dosimetry...) Biological and medical sciences Biological effects of radiation Fundamental and applied biological sciences. Psychology Tissues, organs and organisms biophysics |
title | Pen Dosemeters Electronic Read Unit |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A39%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pen%20Dosemeters%20Electronic%20Read%20Unit&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Castellano,%20A.&rft.date=1985-04-01&rft.volume=11&rft.issue=2&rft.spage=131&rft.epage=132&rft.pages=131-132&rft.issn=0144-8420&rft.eissn=1742-3406&rft.coden=RPDODE&rft_id=info:doi/10.1093/oxfordjournals.rpd.a079457&rft_dat=%3Cistex_cross%3Eark_67375_HXZ_XCCHRKZ9_9%3C/istex_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c186t-64aefe1783ed2edf96b9c357c51627b29428fc2ca31218238e32895412348f23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |